These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
297 related articles for article (PubMed ID: 29378441)
1. Real-time 3D ultrasound based motion tracking for the treatment of mobile organs with MR-guided high-intensity focused ultrasound. Bour P; Ozenne V; Marquet F; Denis de Senneville B; Dumont E; Quesson B Int J Hyperthermia; 2018 Dec; 34(8):1225-1235. PubMed ID: 29378441 [TBL] [Abstract][Full Text] [Related]
3. Real-time method for motion-compensated MR thermometry and MRgHIFU treatment in abdominal organs. Celicanin Z; Auboiroux V; Bieri O; Petrusca L; Santini F; Viallon M; Scheffler K; Salomir R Magn Reson Med; 2014 Oct; 72(4):1087-95. PubMed ID: 24243500 [TBL] [Abstract][Full Text] [Related]
4. Spectrally selective pencil-beam navigator for motion compensation of MR-guided high-intensity focused ultrasound therapy of abdominal organs. Köhler MO; Denis de Senneville B; Quesson B; Moonen CT; Ries M Magn Reson Med; 2011 Jul; 66(1):102-11. PubMed ID: 21305602 [TBL] [Abstract][Full Text] [Related]
5. A framework for the correction of slow physiological drifts during MR-guided HIFU therapies: Proof of concept. Zachiu C; Denis de Senneville B; Moonen C; Ries M Med Phys; 2015 Jul; 42(7):4137-48. PubMed ID: 26133614 [TBL] [Abstract][Full Text] [Related]
6. In-vivo non-invasive motion tracking and correction in high intensity focused ultrasound therapy. Marquet F; Pernot M; Aubry JF; Tanter M; Montaldo G; Fink M Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():688-91. PubMed ID: 17946416 [TBL] [Abstract][Full Text] [Related]
7. Self-Scanned HIFU Ablation of Moving Tissue Using Real-Time Hybrid US-MR Imaging. Lorton O; Guillemin PC; Mori N; Crowe LA; Boudabbous S; Terraz S; Becker CD; Cattin P; Salomir R; Gui L IEEE Trans Biomed Eng; 2019 Aug; 66(8):2182-2191. PubMed ID: 30530308 [TBL] [Abstract][Full Text] [Related]
9. Magnetic resonance imaging for the exploitation of bubble-enhanced heating by high-intensity focused ultrasound: a feasibility study in ex vivo liver. Elbes D; Denost Q; Robert B; Köhler MO; Tanter M; Bruno Q Ultrasound Med Biol; 2014 May; 40(5):956-64. PubMed ID: 24462160 [TBL] [Abstract][Full Text] [Related]
10. Real-time volumetric MRI thermometry of focused ultrasound ablation in vivo: a feasibility study in pig liver and kidney. Quesson B; Laurent C; Maclair G; de Senneville BD; Mougenot C; Ries M; Carteret T; Rullier A; Moonen CT NMR Biomed; 2011 Feb; 24(2):145-53. PubMed ID: 21344531 [TBL] [Abstract][Full Text] [Related]
11. 3-D real-time motion correction in high-intensity focused ultrasound therapy. Pernot M; Tanter M; Fink M Ultrasound Med Biol; 2004 Sep; 30(9):1239-49. PubMed ID: 15550328 [TBL] [Abstract][Full Text] [Related]
12. A clinically feasible treatment protocol for magnetic resonance-guided high-intensity focused ultrasound ablation in the liver. Wijlemans JW; de Greef M; Schubert G; Bartels LW; Moonen CT; van den Bosch MA; Ries M Invest Radiol; 2015 Jan; 50(1):24-31. PubMed ID: 25198833 [TBL] [Abstract][Full Text] [Related]
13. Ultrasonography-based 2D motion-compensated HIFU sonication integrated with reference-free MR temperature monitoring: a feasibility study ex vivo. Auboiroux V; Petrusca L; Viallon M; Goget T; Becker CD; Salomir R Phys Med Biol; 2012 May; 57(10):N159-71. PubMed ID: 22517112 [TBL] [Abstract][Full Text] [Related]
14. Rapid motion correction in MR-guided high-intensity focused ultrasound heating using real-time ultrasound echo information. de Oliveira PL; de Senneville BD; Dragonu I; Moonen CT NMR Biomed; 2010 Nov; 23(9):1103-8. PubMed ID: 20669159 [TBL] [Abstract][Full Text] [Related]
15. High intensity focused ultrasound (HIFU) focal spot localization using harmonic motion imaging (HMI). Han Y; Hou GY; Wang S; Konofagou E Phys Med Biol; 2015 Aug; 60(15):5911-24. PubMed ID: 26184846 [TBL] [Abstract][Full Text] [Related]
16. Optimization of real-time acoustical and mechanical monitoring of high intensity focused ultrasound (HIFU) treatment using harmonic motion imaging for high focused ultrasound (HMIFU). Hou GY; Marquet F; Wang S; Konofagou EE Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():6281-4. PubMed ID: 24111176 [TBL] [Abstract][Full Text] [Related]
17. Real-time monitoring of tissue displacement and temperature changes during MR-guided high intensity focused ultrasound. Bour P; Marquet F; Ozenne V; Toupin S; Dumont E; Aubry JF; Lepetit-Coiffe M; Quesson B Magn Reson Med; 2017 Nov; 78(5):1911-1921. PubMed ID: 28090656 [TBL] [Abstract][Full Text] [Related]
18. Intrapleural fluid infusion for MR-guided high-intensity focused ultrasound ablation in the liver dome. Wijlemans JW; de Greef M; Schubert G; Moonen CT; van den Bosch MA; Ries M Acad Radiol; 2014 Dec; 21(12):1597-602. PubMed ID: 25126972 [TBL] [Abstract][Full Text] [Related]
20. Increasing the HIFU ablation rate through an MRI-guided sonication strategy using shock waves: feasibility in the in vivo porcine liver. Ramaekers P; de Greef M; van Breugel JM; Moonen CT; Ries M Phys Med Biol; 2016 Feb; 61(3):1057-77. PubMed ID: 26757987 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]