BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

276 related articles for article (PubMed ID: 29380190)

  • 1. Comparison of cardiac output optimization with an automated closed-loop goal-directed fluid therapy versus non standardized manual fluid administration during elective abdominal surgery: first prospective randomized controlled trial.
    Lilot M; Bellon A; Gueugnon M; Laplace MC; Baffeleuf B; Hacquard P; Barthomeuf F; Parent C; Tran T; Soubirou JL; Robinson P; Bouvet L; Vassal O; Lehot JJ; Piriou V
    J Clin Monit Comput; 2018 Dec; 32(6):993-1003. PubMed ID: 29380190
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Closed-loop assisted versus manual goal-directed fluid therapy during high-risk abdominal surgery: a case-control study with propensity matching.
    Rinehart J; Lilot M; Lee C; Joosten A; Huynh T; Canales C; Imagawa D; Demirjian A; Cannesson M
    Crit Care; 2015 Mar; 19(1):94. PubMed ID: 25888403
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Goal-Directed fluid therapy with closed-loop assistance during moderate risk surgery using noninvasive cardiac output monitoring: A pilot study.
    Joosten A; Huynh T; Suehiro K; Canales C; Cannesson M; Rinehart J
    Br J Anaesth; 2015 Jun; 114(6):886-92. PubMed ID: 25690834
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Implementation of closed-loop-assisted intra-operative goal-directed fluid therapy during major abdominal surgery: A case-control study with propensity matching.
    Joosten A; Coeckelenbergh S; Delaporte A; Ickx B; Closset J; Roumeguere T; Barvais L; Van Obbergh L; Cannesson M; Rinehart J; Van der Linden P
    Eur J Anaesthesiol; 2018 Sep; 35(9):650-658. PubMed ID: 29750699
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Personalized Versus Protocolized Fluid Management Using Noninvasive Hemodynamic Monitoring (Clearsight System) in Patients Undergoing Moderate-Risk Abdominal Surgery.
    Joosten A; Raj Lawrence S; Colesnicenco A; Coeckelenbergh S; Vincent JL; Van der Linden P; Cannesson M; Rinehart J
    Anesth Analg; 2019 Jul; 129(1):e8-e12. PubMed ID: 29878939
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Crystalloid versus Colloid for Intraoperative Goal-directed Fluid Therapy Using a Closed-loop System: A Randomized, Double-blinded, Controlled Trial in Major Abdominal Surgery.
    Joosten A; Delaporte A; Ickx B; Touihri K; Stany I; Barvais L; Van Obbergh L; Loi P; Rinehart J; Cannesson M; Van der Linden P
    Anesthesiology; 2018 Jan; 128(1):55-66. PubMed ID: 29068831
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Closed-loop fluid administration compared to anesthesiologist management for hemodynamic optimization and resuscitation during surgery: an in vivo study.
    Rinehart J; Lee C; Canales C; Kong A; Kain Z; Cannesson M
    Anesth Analg; 2013 Nov; 117(5):1119-29. PubMed ID: 23835453
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A randomised controlled trial of fluid restriction compared to oesophageal Doppler-guided goal-directed fluid therapy in elective major colorectal surgery within an Enhanced Recovery After Surgery program.
    Phan TD; D'Souza B; Rattray MJ; Johnston MJ; Cowie BS
    Anaesth Intensive Care; 2014 Nov; 42(6):752-60. PubMed ID: 25342408
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of conventional fluid management with PVI-based goal-directed fluid management in elective colorectal surgery.
    Cesur S; Çardaközü T; Kuş A; Türkyılmaz N; Yavuz Ö
    J Clin Monit Comput; 2019 Apr; 33(2):249-257. PubMed ID: 29948666
    [TBL] [Abstract][Full Text] [Related]  

  • 10. First closed-loop goal directed fluid therapy during surgery: a pilot study.
    Rinehart J; Le Manach Y; Douiri H; Lee C; Lilot M; Le K; Canales C; Cannesson M
    Ann Fr Anesth Reanim; 2014 Mar; 33(3):e35-41. PubMed ID: 24378044
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Practical impact of a decision support for goal-directed fluid therapy on protocol adherence: a clinical implementation study in patients undergoing major abdominal surgery.
    Joosten A; Hafiane R; Pustetto M; Van Obbergh L; Quackels T; Buggenhout A; Vincent JL; Ickx B; Rinehart J
    J Clin Monit Comput; 2019 Feb; 33(1):15-24. PubMed ID: 29779129
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Review article: closed-loop systems in anesthesia: is there a potential for closed-loop fluid management and hemodynamic optimization?
    Rinehart J; Liu N; Alexander B; Cannesson M
    Anesth Analg; 2012 Jan; 114(1):130-43. PubMed ID: 21965362
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Perioperative goal-directed hemodynamic optimization using noninvasive cardiac output monitoring in major abdominal surgery: a prospective, randomized, multicenter, pragmatic trial: POEMAS Study (PeriOperative goal-directed thErapy in Major Abdominal Surgery).
    Pestaña D; Espinosa E; Eden A; Nájera D; Collar L; Aldecoa C; Higuera E; Escribano S; Bystritski D; Pascual J; Fernández-Garijo P; de Prada B; Muriel A; Pizov R
    Anesth Analg; 2014 Sep; 119(3):579-587. PubMed ID: 25010820
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Computer-assisted Individualized Hemodynamic Management Reduces Intraoperative Hypotension in Intermediate- and High-risk Surgery: A Randomized Controlled Trial.
    Joosten A; Rinehart J; Van der Linden P; Alexander B; Penna C; De Montblanc J; Cannesson M; Vincent JL; Vicaut E; Duranteau J
    Anesthesiology; 2021 Aug; 135(2):258-272. PubMed ID: 33951140
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pleth variability index versus pulse pressure variation for intraoperative goal-directed fluid therapy in patients undergoing low-to-moderate risk abdominal surgery: a randomized controlled trial.
    Coeckelenbergh S; Delaporte A; Ghoundiwal D; Bidgoli J; Fils JF; Schmartz D; Van der Linden P
    BMC Anesthesiol; 2019 Mar; 19(1):34. PubMed ID: 30851740
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The added value of cardiac index and pulse pressure variation monitoring to mean arterial pressure-guided volume therapy in moderate-risk abdominal surgery (COGUIDE): a pragmatic multicentre randomised controlled trial.
    Stens J; Hering JP; van der Hoeven CWP; Boom A; Traast HS; Garmers LE; Loer SA; Boer C
    Anaesthesia; 2017 Sep; 72(9):1078-1087. PubMed ID: 28543041
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of fluid strategy on stroke volume, cardiac output, and fluid responsiveness in adult patients undergoing major abdominal surgery: a sub-study of the Restrictive versus Liberal Fluid Therapy in Major Abdominal Surgery (RELIEF) trial.
    Phan TD; Uda Y; Peyton PJ; Kluger R; Myles PS
    Br J Anaesth; 2021 Apr; 126(4):818-825. PubMed ID: 33632521
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: results of prospective randomized study.
    Benes J; Chytra I; Altmann P; Hluchy M; Kasal E; Svitak R; Pradl R; Stepan M
    Crit Care; 2010; 14(3):R118. PubMed ID: 20553586
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A prospective comparison of a noninvasive cardiac output monitor versus esophageal Doppler monitor for goal-directed fluid therapy in colorectal surgery patients.
    Waldron NH; Miller TE; Thacker JK; Manchester AK; White WD; Nardiello J; Elgasim MA; Moon RE; Gan TJ
    Anesth Analg; 2014 May; 118(5):966-75. PubMed ID: 24681660
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Impact of a goal directed fluid therapy algorithm on postoperative morbidity in patients undergoing open right hepatectomy: a single centre retrospective observational study.
    Weinberg L; Mackley L; Ho A; Mcguigan S; Ianno D; Yii M; Banting J; Muralidharan V; Tan CO; Nikfarjam M; Christophi C
    BMC Anesthesiol; 2019 Jul; 19(1):135. PubMed ID: 31366327
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.