BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

510 related articles for article (PubMed ID: 29389770)

  • 1. One-step Minimally Invasive Pedicle Screw Instrumentation Using O-Arm and Stealth Navigation.
    Kleck CJ; Johnson C; Akiyama M; Burger EL; Cain CJ; Patel VV
    Clin Spine Surg; 2018 Jun; 31(5):197-202. PubMed ID: 29389770
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Percutaneous pedicle screw placement under single dimensional fluoroscopy with a designed pedicle finder-a technical note and case series.
    Tsuang FY; Chen CH; Kuo YJ; Tseng WL; Chen YS; Lin CJ; Liao CJ; Lin FH; Chiang CJ
    Spine J; 2017 Sep; 17(9):1373-1380. PubMed ID: 28645672
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Early experience of placing image-guided minimally invasive pedicle screws without K-wires or bone-anchored trackers.
    Malham GM; Parker RM
    J Neurosurg Spine; 2018 Apr; 28(4):357-363. PubMed ID: 29372857
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Electromyography stimulation compared with intraoperative O-arm imaging for evaluating pedicle screw breaches in lumbar spine surgery: a prospective analysis of 1006 screws in 164 patients.
    Ravindra VM; Kalra RR; Dailey AT
    Spine J; 2019 Feb; 19(2):206-211. PubMed ID: 29960110
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Clinical and radiographic outcomes of minimally invasive percutaneous pedicle screw placement with intraoperative CT (O-arm) image guidance navigation.
    Kim TT; Drazin D; Shweikeh F; Pashman R; Johnson JP
    Neurosurg Focus; 2014 Mar; 36(3):E1. PubMed ID: 24580001
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pedicle screw accuracy placed with assistance of machine vision technology in patients with neuromuscular scoliosis.
    Sakhrekar R; Shkumat N; Ertl-Wagner B; Lewis S; Lebel D; McVey MJ; Camp M
    Spine Deform; 2024 May; 12(3):739-746. PubMed ID: 38413472
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Does Navigation Improve Accuracy of Placement of Pedicle Screws in Single-level Lumbar Degenerative Spondylolisthesis?: A Comparison Between Free-hand and Three-dimensional O-Arm Navigation Techniques.
    Boon Tow BP; Yue WM; Srivastava A; Lai JM; Guo CM; Wearn Peng BC; Chen JL; Yew AK; Seng C; Tan SB
    J Spinal Disord Tech; 2015 Oct; 28(8):E472-7. PubMed ID: 23981926
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Improved Accuracy of Minimally Invasive Transpedicular Screw Placement in the Lumbar Spine With 3-Dimensional Stereotactic Image Guidance: A Comparative Meta-Analysis.
    Bourgeois AC; Faulkner AR; Bradley YC; Pasciak AS; Barlow PB; Gash JR; Reid WS
    J Spinal Disord Tech; 2015 Nov; 28(9):324-9. PubMed ID: 25089676
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Navigated robot-guided pedicle screws placed successfully in single-position lateral lumbar interbody fusion.
    Huntsman KT; Riggleman JR; Ahrendtsen LA; Ledonio CG
    J Robot Surg; 2020 Aug; 14(4):643-647. PubMed ID: 31625074
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Retrospective computed tomography scan analysis of percutaneously inserted pedicle screws for posterior transpedicular stabilization of the thoracic and lumbar spine: accuracy and complication rates.
    Raley DA; Mobbs RJ
    Spine (Phila Pa 1976); 2012 May; 37(12):1092-100. PubMed ID: 22037528
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of Screw Placement Accuracy in Circumferential Lumbar Arthrodesis Using Robotic Assistance and Intraoperative Flat-Panel Computed Tomography.
    Chenin L; Capel C; Fichten A; Peltier J; Lefranc M
    World Neurosurg; 2017 Sep; 105():86-94. PubMed ID: 28576710
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Use of the Airo mobile intraoperative CT system versus the O-arm for transpedicular screw fixation in the thoracic and lumbar spine: a retrospective cohort study of 263 patients.
    Scarone P; Vincenzo G; Distefano D; Del Grande F; Cianfoni A; Presilla S; Reinert M
    J Neurosurg Spine; 2018 Oct; 29(4):397-406. PubMed ID: 29979141
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Augmented reality in minimally invasive spine surgery: early efficiency and complications of percutaneous pedicle screw instrumentation.
    Butler AJ; Colman MW; Lynch J; Phillips FM
    Spine J; 2023 Jan; 23(1):27-33. PubMed ID: 36182070
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pedicle screw placement accuracy using ultra-low radiation imaging with image enhancement versus conventional fluoroscopy in minimally invasive transforaminal lumbar interbody fusion: an internally randomized controlled trial.
    Nayar G; Blizzard DJ; Wang TY; Cook S; Back AG; Vincent D; Karikari IO
    J Neurosurg Spine; 2018 Feb; 28(2):186-193. PubMed ID: 29192879
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Incidence of lumbar spine pedicle breach after percutaneous screw fixation: a radiographic evaluation of 601 screws in 151 patients.
    Smith ZA; Sugimoto K; Lawton CD; Fessler RG
    J Spinal Disord Tech; 2014 Oct; 27(7):358-63. PubMed ID: 22688617
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of the percutaneous screw placement precision of isocentric C-arm 3-dimensional fluoroscopy-navigated pedicle screw implantation and conventional fluoroscopy method with minimally invasive surgery.
    Nakashima H; Sato K; Ando T; Inoh H; Nakamura H
    J Spinal Disord Tech; 2009 Oct; 22(7):468-72. PubMed ID: 20075808
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A prospective multicenter registry on the accuracy of pedicle screw placement in the thoracic, lumbar, and sacral levels with the use of the O-arm imaging system and StealthStation Navigation.
    Van de Kelft E; Costa F; Van der Planken D; Schils F
    Spine (Phila Pa 1976); 2012 Dec; 37(25):E1580-7. PubMed ID: 23196967
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Does robot-assisted navigation influence pedicle screw selection and accuracy in minimally invasive spine surgery?
    Shafi KA; Pompeu YA; Vaishnav AS; Mai E; Sivaganesan A; Shahi P; Qureshi SA
    Neurosurg Focus; 2022 Jan; 52(1):E4. PubMed ID: 34973674
    [TBL] [Abstract][Full Text] [Related]  

  • 19. O-Arm Accuracy and Radiation Exposure in Adult Deformity Surgery.
    Croci DM; Nguyen S; Streitmatter SW; Sherrod BA; Hardy J; Cole KL; Gamblin AS; Bisson EF; Mazur MD; Dailey AT
    World Neurosurg; 2023 Mar; 171():e440-e446. PubMed ID: 36528322
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Freehand technique for C2 pedicle and pars screw placement: is it safe?
    Punyarat P; Buchowski JM; Klawson BT; Peters C; Lertudomphonwanit T; Riew KD
    Spine J; 2018 Jul; 18(7):1197-1203. PubMed ID: 29155344
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 26.