510 related articles for article (PubMed ID: 29389770)
21. Image-guided spine surgery: a cadaver study comparing conventional open laminoforaminotomy and two image-guided techniques for pedicle screw placement in posterolateral fusion and nonfusion models.
Austin MS; Vaccaro AR; Brislin B; Nachwalter R; Hilibrand AS; Albert TJ
Spine (Phila Pa 1976); 2002 Nov; 27(22):2503-8. PubMed ID: 12435982
[TBL] [Abstract][Full Text] [Related]
22. O-Arm Accuracy and Radiation Exposure in Adult Deformity Surgery.
Croci DM; Nguyen S; Streitmatter SW; Sherrod BA; Hardy J; Cole KL; Gamblin AS; Bisson EF; Mazur MD; Dailey AT
World Neurosurg; 2023 Mar; 171():e440-e446. PubMed ID: 36528322
[TBL] [Abstract][Full Text] [Related]
23. Percutaneous "K-wireless" pedicle screw fixation technique: an evaluation of the initial experience of 100 screws with assessment of accuracy, radiation exposure, and procedure time.
Spitz SM; Sandhu FA; Voyadzis JM
J Neurosurg Spine; 2015 Apr; 22(4):422-31. PubMed ID: 25658468
[TBL] [Abstract][Full Text] [Related]
24. Does Navigation Improve Pedicle Screw Placement Accuracy? Comparison Between Navigated and Non-navigated Percutaneous and Open Fixations.
Innocenzi G; Bistazzoni S; D'Ercole M; Cardarelli G; Ricciardi F
Acta Neurochir Suppl; 2017; 124():289-295. PubMed ID: 28120086
[TBL] [Abstract][Full Text] [Related]
25. Minimally Invasive Pedicle Screw Fixation Combined with Percutaneous Kyphoplasty Under O-Arm Navigation for the Treatment of Metastatic Spinal Tumors with Posterior Wall Destruction.
Zhou ZZ; Wang YM; Liang X; Ze X; Liu H; Chen KW; Zhu XY; Sun ZY; Qian ZL
Orthop Surg; 2020 Aug; 12(4):1131-1139. PubMed ID: 32578396
[TBL] [Abstract][Full Text] [Related]
26. Accuracy of K-Wireless Insertion of Percutaneous Pedicle Screws Using Computer-Assisted Spinal Navigation: A Systematic Review and Single-Center Experience.
O'Donohoe TJ; Dawes BH; Thien C; Wang YY
World Neurosurg; 2020 Jun; 138():e267-e274. PubMed ID: 32105880
[TBL] [Abstract][Full Text] [Related]
27. The accuracy of 3D image navigation with a cutaneously fixed dynamic reference frame in minimally invasive transforaminal lumbar interbody fusion.
Cho JY; Chan CK; Lee SH; Lee HY
Comput Aided Surg; 2012; 17(6):300-9. PubMed ID: 23098190
[TBL] [Abstract][Full Text] [Related]
28. Fluoroscopy-Assisted Freehand Versus 3D-Navigated Imaging-Assisted Pedicle Screw Insertion: A Multicenter Study.
Cammarata G; Scalia G; Costanzo R; Umana GE; Furnari M; Ponzo G; Giuffrida M; Maugeri R; Iacopino DG; Nicoletti GF; Graziano F
Acta Neurochir Suppl; 2023; 135():425-430. PubMed ID: 38153504
[TBL] [Abstract][Full Text] [Related]
29. Pedicle Screw Placement Using Augmented Reality Surgical Navigation With Intraoperative 3D Imaging: A First In-Human Prospective Cohort Study.
Elmi-Terander A; Burström G; Nachabe R; Skulason H; Pedersen K; Fagerlund M; Ståhl F; Charalampidis A; Söderman M; Holmin S; Babic D; Jenniskens I; Edström E; Gerdhem P
Spine (Phila Pa 1976); 2019 Apr; 44(7):517-525. PubMed ID: 30234816
[TBL] [Abstract][Full Text] [Related]
30. Improving accuracy and reducing radiation exposure in minimally invasive lumbar interbody fusion.
Wood MJ; Mannion RJ
J Neurosurg Spine; 2010 May; 12(5):533-9. PubMed ID: 20433301
[TBL] [Abstract][Full Text] [Related]
31. Minimally invasive lumbar pedicle screw fixation using cortical bone trajectory - Screw accuracy, complications, and learning curve in 100 screw placements.
Dayani F; Chen YR; Johnson E; Deb S; Wu Y; Pham L; Singh H
J Clin Neurosci; 2019 Mar; 61():106-111. PubMed ID: 30420203
[TBL] [Abstract][Full Text] [Related]
32. Reduction in Radiation Exposure in Minimally Invasive Pedicle Screw Placement Using a Tubular Retractor: A Pilot Study.
Oki T; Lefor AK; Nakamura K; Higashi T; Oki I
Tomography; 2022 Dec; 9(1):12-24. PubMed ID: 36648989
[TBL] [Abstract][Full Text] [Related]
33. One-step insertion of navigated pedicle screws in minimally invasive transforaminal lumbar interbody fusion (MITLIF): preliminary results of a novel technique.
Harel R; Kimchi G; Knoller N
Br J Neurosurg; 2021 Dec; 35(6):753-756. PubMed ID: 32522043
[TBL] [Abstract][Full Text] [Related]
34. Incidence of and risk factors for superior facet violation in minimally invasive versus open pedicle screw placement during transforaminal lumbar interbody fusion: a comparative analysis.
Lau D; Terman SW; Patel R; La Marca F; Park P
J Neurosurg Spine; 2013 Apr; 18(4):356-61. PubMed ID: 23394166
[TBL] [Abstract][Full Text] [Related]
35. Cervical pedicle screw instrumentation is more reliable with O-arm-based 3D navigation: analysis of cervical pedicle screw placement accuracy with O-arm-based 3D navigation.
Chachan S; Bin Abd Razak HR; Loo WL; Allen JC; Shree Kumar D
Eur Spine J; 2018 Nov; 27(11):2729-2736. PubMed ID: 29651593
[TBL] [Abstract][Full Text] [Related]
36. Increased Radiation but No Benefits in Pedicle Screw Accuracy With Navigation versus a Freehand Technique in Scoliosis Surgery.
Urbanski W; Jurasz W; Wolanczyk M; Kulej M; Morasiewicz P; Dragan SL; Zaluski R; Miekisiak G; Dragan SF
Clin Orthop Relat Res; 2018 May; 476(5):1020-1027. PubMed ID: 29432262
[TBL] [Abstract][Full Text] [Related]
37. Placement of thoracolumbar pedicle screws using three-dimensional image guidance: experience in a large patient cohort.
Nottmeier EW; Seemer W; Young PM
J Neurosurg Spine; 2009 Jan; 10(1):33-9. PubMed ID: 19119930
[TBL] [Abstract][Full Text] [Related]
38. [Comparison of screw placement guided by O-arm navigation and ultrasound volume navigation in minimally invasive transforaminal lumbar interbody fusion].
Lin X; Chang Q; Shang L; Shen S; Fu Z; Wang Y; Zhou L; Fu H; Zhao G
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2023 Nov; 37(11):1403-1409. PubMed ID: 37987052
[TBL] [Abstract][Full Text] [Related]
39. Application of different thresholds for instrumentation device testing in minimally invasive lumbosacral spine fixation.
Wu Y; Cohen D; Tellez MJ; DiGiacinto GV; Barquero AV; Ulkatan S
J Clin Neurosci; 2020 Feb; 72():224-228. PubMed ID: 31866354
[TBL] [Abstract][Full Text] [Related]
40. Clinical pedicle screw accuracy and deviation from planning in robot-guided spine surgery: robot-guided pedicle screw accuracy.
van Dijk JD; van den Ende RP; Stramigioli S; Köchling M; Höss N
Spine (Phila Pa 1976); 2015 Sep; 40(17):E986-91. PubMed ID: 25943084
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]