155 related articles for article (PubMed ID: 29389805)
1. Radiotherapy and risk of implantable cardioverter-defibrillator malfunctions: experimental data from direct exposure at increasing doses.
Zecchin M; Artico J; Morea G; Severgnini M; Bianco E; De Luca A; Fantasia AZ; Salvatore L; Milan V; Lucarelli M; Dissegna R; Cannatà A; Sinagra G
J Cardiovasc Med (Hagerstown); 2018 Apr; 19(4):155-160. PubMed ID: 29389805
[TBL] [Abstract][Full Text] [Related]
2. A randomized in vitro evaluation of transient and permanent cardiac implantable electronic device malfunctions following direct exposure up to 10 Gy.
Falco MD; Genovesi D; Caravatta L; Di Carlo C; Bliakharskaia E; Appignani M; Faustino M; Furia N; Di Girolamo E
Strahlenther Onkol; 2021 Mar; 197(3):198-208. PubMed ID: 32561941
[TBL] [Abstract][Full Text] [Related]
3. High incidence of implantable cardioverter defibrillator malfunctions during radiation therapy: neutrons as a probable cause of soft errors.
Elders J; Kunze-Busch M; Smeenk RJ; Smeets JL
Europace; 2013 Jan; 15(1):60-5. PubMed ID: 22848077
[TBL] [Abstract][Full Text] [Related]
4. Malfunction of cardiac devices after radiotherapy without direct exposure to ionizing radiation: mechanisms and experimental data.
Zecchin M; Morea G; Severgnini M; Sergi E; Baratto Roldan A; Bianco E; Magnani S; De Luca A; Zorzin Fantasia A; Salvatore L; Milan V; Giannini G; Sinagra G
Europace; 2016 Feb; 18(2):288-93. PubMed ID: 26333380
[TBL] [Abstract][Full Text] [Related]
5. The effect of radiotherapy beam energy on modern cardiac devices: an in vitro study.
Zaremba T; Jakobsen AR; Thøgersen AM; Oddershede L; Riahi S
Europace; 2014 Apr; 16(4):612-6. PubMed ID: 23933852
[TBL] [Abstract][Full Text] [Related]
6. Comparison of the effects of high-energy photon beam irradiation (10 and 18 MV) on 2 types of implantable cardioverter-defibrillators.
Hashii H; Hashimoto T; Okawa A; Shida K; Isobe T; Hanmura M; Nishimura T; Aonuma K; Sakae T; Sakurai H
Int J Radiat Oncol Biol Phys; 2013 Mar; 85(3):840-5. PubMed ID: 22818414
[TBL] [Abstract][Full Text] [Related]
7. In-vitro investigation of cardiac implantable electronic device malfunction during and after direct photon exposure: A three-centres experience.
Daniela Falco M; Andreoli S; Delana A; Barbareschi A; De Filippo P; Leidi C; Marini M; Appignani M; Genovesi D; Di Girolamo E
Phys Med; 2022 Feb; 94():94-101. PubMed ID: 35007940
[TBL] [Abstract][Full Text] [Related]
8. Influence of radiotherapy on the latest generation of implantable cardioverter-defibrillators.
Hurkmans CW; Scheepers E; Springorum BG; Uiterwaal H
Int J Radiat Oncol Biol Phys; 2005 Sep; 63(1):282-9. PubMed ID: 16111598
[TBL] [Abstract][Full Text] [Related]
9. Effect of radiation therapy on permanent pacemaker and implantable cardioverter-defibrillator function.
Makkar A; Prisciandaro J; Agarwal S; Lusk M; Horwood L; Moran J; Fox C; Hayman JA; Ghanbari H; Roberts B; Belardi D; Latchamsetty R; Crawford T; Good E; Jongnarangsin K; Bogun F; Chugh A; Oral H; Morady F; Pelosi F
Heart Rhythm; 2012 Dec; 9(12):1964-8. PubMed ID: 23102626
[TBL] [Abstract][Full Text] [Related]
10. Effects of high-dose radiotherapy on implantable cardioverter defibrillators: an in vivo porcine study.
Zaremba T; Jakobsen AR; Thøgersen AM; Riahi S; Kjærgaard B
Pacing Clin Electrophysiol; 2013 Dec; 36(12):1558-63. PubMed ID: 23952539
[TBL] [Abstract][Full Text] [Related]
11. Risk of device malfunction in cancer patients with implantable cardiac device undergoing radiotherapy: a population-based cohort study.
Zaremba T; Jakobsen AR; Søgaard M; Thøgersen AM; Johansen MB; Madsen LB; Riahi S
Pacing Clin Electrophysiol; 2015 Mar; 38(3):343-56. PubMed ID: 25601489
[TBL] [Abstract][Full Text] [Related]
12. A review of implantable cardioverter defibrillator failures during radiation therapy in three Sydney hospitals.
Hudson FJ; Ryan EA
J Med Imaging Radiat Oncol; 2017 Aug; 61(4):517-521. PubMed ID: 28256052
[TBL] [Abstract][Full Text] [Related]
13. Influence of secondary neutrons induced by proton radiotherapy for cancer patients with implantable cardioverter defibrillators.
Hashimoto T; Isobe T; Hashii H; Kumada H; Tada H; Okumura T; Tsuboi K; Sakae T; Aonuma K; Sakurai H
Radiat Oncol; 2012 Jan; 7():10. PubMed ID: 22284700
[TBL] [Abstract][Full Text] [Related]
14. Monitoring of CRT-D devices during radiation therapy in vitro.
Augustynek M; Korpas D; Penhaker M; Cvek J; Binarova A
Biomed Eng Online; 2016 Mar; 15():29. PubMed ID: 26960554
[TBL] [Abstract][Full Text] [Related]
15. Radiation tolerance of contemporary implantable cardioverter-defibrillators.
Mollerus M; Naslund L; Lipinski M; Meyer A; Libey B; Dornfeld K
J Interv Card Electrophysiol; 2014 Mar; 39(2):171-5. PubMed ID: 24317919
[TBL] [Abstract][Full Text] [Related]
16. Effects of scatter radiation on ICD and CRT function.
Kapa S; Fong L; Blackwell CR; Herman MG; Schomberg PJ; Hayes DL
Pacing Clin Electrophysiol; 2008 Jun; 31(6):727-32. PubMed ID: 18507546
[TBL] [Abstract][Full Text] [Related]
17. Longevity of implantable cardioverter defibrillators: a comparison among manufacturers and over time.
von Gunten S; Schaer BA; Yap SC; Szili-Torok T; Kühne M; Sticherling C; Osswald S; Theuns DA
Europace; 2016 May; 18(5):710-7. PubMed ID: 26609076
[TBL] [Abstract][Full Text] [Related]
18. Pacemaker and ICD generator malfunctions: analysis of Food and Drug Administration annual reports.
Maisel WH; Moynahan M; Zuckerman BD; Gross TP; Tovar OH; Tillman DB; Schultz DB
JAMA; 2006 Apr; 295(16):1901-6. PubMed ID: 16639048
[TBL] [Abstract][Full Text] [Related]
19. Implantable cardioverter-defibrillator longevity under clinical circumstances: an analysis according to device type, generation, and manufacturer.
Thijssen J; Borleffs CJ; van Rees JB; Man S; de Bie MK; Venlet J; van der Velde ET; van Erven L; Schalij MJ
Heart Rhythm; 2012 Apr; 9(4):513-9. PubMed ID: 22094073
[TBL] [Abstract][Full Text] [Related]
20. Multicenter experience with failed and recalled implantable cardioverter-defibrillator pulse generators.
Hauser RG; Hayes DL; Epstein AE; Cannom DS; Vlay SC; Song SL; Tyers GF
Heart Rhythm; 2006 Jun; 3(6):640-4. PubMed ID: 16731462
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]