These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

331 related articles for article (PubMed ID: 29391564)

  • 1. Multi-slice ptychographic tomography.
    Li P; Maiden A
    Sci Rep; 2018 Feb; 8(1):2049. PubMed ID: 29391564
    [TBL] [Abstract][Full Text] [Related]  

  • 2. X-ray ptychography with extended depth of field.
    Tsai EH; Usov I; Diaz A; Menzel A; Guizar-Sicairos M
    Opt Express; 2016 Dec; 24(25):29089-29108. PubMed ID: 27958573
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Resolving 500 nm axial separation by multi-slice X-ray ptychography.
    Huang X; Yan H; He Y; Ge M; Öztürk H; Fang YLL; Ha S; Lin M; Lu M; Nazaretski E; Robinson IK; Chu YS
    Acta Crystallogr A Found Adv; 2019 Mar; 75(Pt 2):336-341. PubMed ID: 30821266
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ptychographic transmission microscopy in three dimensions using a multi-slice approach.
    Maiden AM; Humphry MJ; Rodenburg JM
    J Opt Soc Am A Opt Image Sci Vis; 2012 Aug; 29(8):1606-14. PubMed ID: 23201876
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Electron Ptychographic Diffractive Imaging of Boron Atoms in LaB
    Wang P; Zhang F; Gao S; Zhang M; Kirkland AI
    Sci Rep; 2017 Jun; 7(1):2857. PubMed ID: 28588219
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Extending the depth of field for ptychography using complex-valued wavelets.
    Huang X; Yan H; Robinson IK; Chu YS
    Opt Lett; 2019 Feb; 44(3):503-506. PubMed ID: 30702664
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Virtual depth-scan multi-slice ptychography for improved three-dimensional imaging.
    Xing Z; Xu Z; Zhang X; Chen B; Guo Z; Wang J; Wang Y; Tai R
    Opt Express; 2021 May; 29(11):16214-16227. PubMed ID: 34154189
    [TBL] [Abstract][Full Text] [Related]  

  • 8. X-ray ptychographic computed tomography at 16 nm isotropic 3D resolution.
    Holler M; Diaz A; Guizar-Sicairos M; Karvinen P; Färm E; Härkönen E; Ritala M; Menzel A; Raabe J; Bunk O
    Sci Rep; 2014 Jan; 4():3857. PubMed ID: 24457289
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Electron ptychographic microscopy for three-dimensional imaging.
    Gao S; Wang P; Zhang F; Martinez GT; Nellist PD; Pan X; Kirkland AI
    Nat Commun; 2017 Jul; 8(1):163. PubMed ID: 28761117
    [TBL] [Abstract][Full Text] [Related]  

  • 10. First X-ray spectral ptychography and resonant ptychographic computed tomography experiments at the SWING beamline from Synchrotron SOLEIL.
    Kulow A; Pérez J; Boudjehem R; Gautier E; Pairis S; Ould-Chikh S; Hazemann JL; da Silva JC
    J Synchrotron Radiat; 2024 Jul; 31(Pt 4):867-876. PubMed ID: 38771779
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ptychographic microscope for three-dimensional imaging.
    Godden TM; Suman R; Humphry MJ; Rodenburg JM; Maiden AM
    Opt Express; 2014 May; 22(10):12513-23. PubMed ID: 24921369
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Multi-beam X-ray ptychography for high-throughput coherent diffraction imaging.
    Yao Y; Jiang Y; Klug JA; Wojcik M; Maxey ER; Sirica NS; Roehrig C; Cai Z; Vogt S; Lai B; Deng J
    Sci Rep; 2020 Nov; 10(1):19550. PubMed ID: 33177558
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Probe retrieval in ptychographic coherent diffractive imaging.
    Thibault P; Dierolf M; Bunk O; Menzel A; Pfeiffer F
    Ultramicroscopy; 2009 Mar; 109(4):338-43. PubMed ID: 19201540
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Computational requirements for real-time ptychographic image reconstruction.
    Datta K; Rittenbach A; Kang DI; Walters JP; Crago SP; Damoulakis J
    Appl Opt; 2019 Mar; 58(7):B19-B27. PubMed ID: 30874231
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Possibility of high-resolution ptychographic iterative imaging with low energy electrons: dynamical calculations.
    Wang L; Liu C; Rodenburg JM
    Microscopy (Oxf); 2015 Apr; 64(2):105-10. PubMed ID: 25543180
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ptychographic coherent x-ray diffractive imaging in the water window.
    Giewekemeyer K; Beckers M; Gorniak T; Grunze M; Salditt T; Rosenhahn A
    Opt Express; 2011 Jan; 19(2):1037-50. PubMed ID: 21263642
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Multi-slice ptychography enables high-resolution measurements in extended chemical reactors.
    Kahnt M; Grote L; Brückner D; Seyrich M; Wittwer F; Koziej D; Schroer CG
    Sci Rep; 2021 Jan; 11(1):1500. PubMed ID: 33452343
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Diffraction tomography with Fourier ptychography.
    Horstmeyer R; Chung J; Ou X; Zheng G; Yang C
    Optica; 2016 Aug; 3(8):827-835. PubMed ID: 28736737
    [TBL] [Abstract][Full Text] [Related]  

  • 19. zPIE: an autofocusing algorithm for ptychography.
    Loetgering L; Du M; Eikema KSE; Witte S
    Opt Lett; 2020 Apr; 45(7):2030-2033. PubMed ID: 32236060
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ptychographic optical coherence tomography.
    Du M; Loetgering L; Eikema KSE; Witte S
    Opt Lett; 2021 Mar; 46(6):1337-1340. PubMed ID: 33720181
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.