417 related articles for article (PubMed ID: 29392383)
21. Comparative study of medial opening-wedge high tibial osteotomy using 2 different implants.
Jung WH; Chun CW; Lee JH; Ha JH; Kim JH; Jeong JH
Arthroscopy; 2013 Jun; 29(6):1063-71. PubMed ID: 23623294
[TBL] [Abstract][Full Text] [Related]
22. Fracture strain and stability with additional locking screws in intramedullary nailing: a biomechanical study.
Sayana MK; Davis BJ; Kapoor B; Rahmatalla A; Maffulli N
J Trauma; 2006 May; 60(5):1053-7. PubMed ID: 16688070
[TBL] [Abstract][Full Text] [Related]
23. Biomechanical comparison of intramedullar versus extramedullar stabilization of intra-articular tibial plateau fractures.
Högel F; Hoffmann S; Panzer S; Wimber J; Bühren V; Augat P
Arch Orthop Trauma Surg; 2013 Jan; 133(1):59-64. PubMed ID: 23076657
[TBL] [Abstract][Full Text] [Related]
24. Opening wedge high tibial osteotomy performed without filling the defect but with locking plate fixation (TomoFix™) and early weight-bearing: prospective evaluation of bone union, precision and maintenance of correction in 51 cases.
Brosset T; Pasquier G; Migaud H; Gougeon F
Orthop Traumatol Surg Res; 2011 Nov; 97(7):705-11. PubMed ID: 22001198
[TBL] [Abstract][Full Text] [Related]
25. Long-term follow-up of tibial shaft fractures treated with intramedullary nailing.
Lefaivre KA; Guy P; Chan H; Blachut PA
J Orthop Trauma; 2008 Sep; 22(8):525-9. PubMed ID: 18758282
[TBL] [Abstract][Full Text] [Related]
26. Angle stable locking reduces interfragmentary movements and promotes healing after unreamed nailing. Study of a displaced osteotomy model in sheep tibiae.
Kaspar K; Schell H; Seebeck P; Thompson MS; Schütz M; Haas NP; Duda GN
J Bone Joint Surg Am; 2005 Sep; 87(9):2028-37. PubMed ID: 16140819
[TBL] [Abstract][Full Text] [Related]
27. Placement-induced effects on high tibial osteotomized construct - biomechanical tests and finite-element analyses.
Luo CA; Hwa SY; Lin SC; Chen CM; Tseng CS
BMC Musculoskelet Disord; 2015 Sep; 16():235. PubMed ID: 26337985
[TBL] [Abstract][Full Text] [Related]
28. Intramedullary stabilization of extraarticular proximal tibial fractures: a biomechanical comparison of intramedullary and extramedullary implants including a new proximal tibia nail (PTN).
Hansen M; Mehler D; Hessmann MH; Blum J; Rommens PM
J Orthop Trauma; 2007; 21(10):701-9. PubMed ID: 17986887
[TBL] [Abstract][Full Text] [Related]
29. A new angle stable nailing concept for the treatment of distal tibia fractures.
Kuhn S; Appelmann P; Pairon P; Mehler D; Hartmann F; Rommens PM
Int Orthop; 2014 Jun; 38(6):1255-60. PubMed ID: 24402556
[TBL] [Abstract][Full Text] [Related]
30. Distal Locking Screws for Intramedullary Nailing of Tibial Fractures.
Agathangelidis F; Petsatodis G; Kirkos J; Papadopoulos P; Karataglis D; Christodoulou A
Orthopedics; 2016; 39(2):e253-8. PubMed ID: 26840700
[TBL] [Abstract][Full Text] [Related]
31. Stability of two angular stable locking plates for open wedge high tibial osteotomy (HTO): TomoFix™ versus LOQTEQ® HTO plate.
Petersen W; Wall A; Paulin T; Park HU; Heymann L
Arch Orthop Trauma Surg; 2014 Oct; 134(10):1437-42. PubMed ID: 25015791
[TBL] [Abstract][Full Text] [Related]
32. Angle stable locking nails versus conventionally locked intramedullary nails in proximal tibial shaft fractures: a biomechanical study.
Thelen S; Betsch M; Grassmann JP; Spoor V; Eichler C; Koebke J; Windolf J; Hakimi M; Wild M
Arch Orthop Trauma Surg; 2012 Jan; 132(1):57-63. PubMed ID: 21877127
[TBL] [Abstract][Full Text] [Related]
33. Retrograde tibial nailing: a minimally invasive and biomechanically superior alternative to angle-stable plate osteosynthesis in distal tibia fractures.
Kuhn S; Appelmann P; Mehler D; Pairon P; Rommens PM
J Orthop Surg Res; 2014 May; 9():35. PubMed ID: 24886667
[TBL] [Abstract][Full Text] [Related]
34. Modified tibial nails for treating distal tibia fractures.
Gorczyca JT; McKale J; Pugh K; Pienkowski D
J Orthop Trauma; 2002 Jan; 16(1):18-22. PubMed ID: 11782627
[TBL] [Abstract][Full Text] [Related]
35. Intramedullary nailing of extra-articular distal tibial fractures.
Hadeed MM; Prakash H; Yarboro SR; Weiss DB
Bone Joint J; 2021 Feb; 103-B(2):294-298. PubMed ID: 33517721
[TBL] [Abstract][Full Text] [Related]
36. Plate-related results of opening wedge high tibial osteotomy with a carbon fiber reinforced poly-ether-ether-ketone (CF-PEEK) plate fixation: a retrospective case series of 346 knees.
Hartz C; Wischatta R; Klostermeier E; Paetzold M; Gerlach K; Pries F
J Orthop Surg Res; 2019 Dec; 14(1):466. PubMed ID: 31881906
[TBL] [Abstract][Full Text] [Related]
37. [Fixation of proximal tibia medial opening wedge osteotomy using plates with wedges].
Esenkaya I
Acta Orthop Traumatol Turc; 2005; 39(3):211-23. PubMed ID: 16141727
[TBL] [Abstract][Full Text] [Related]
38. Intramedullary nailing for tibial shaft fractures in adults.
Duan X; Al-Qwbani M; Zeng Y; Zhang W; Xiang Z
Cochrane Database Syst Rev; 2012 Jan; 1():CD008241. PubMed ID: 22258982
[TBL] [Abstract][Full Text] [Related]
39. Assessing the local mechanical environment in medial opening wedge high tibial osteotomy using finite element analysis.
Pauchard Y; Ivanov TG; McErlain DD; Milner JS; Giffin JR; Birmingham TB; Holdsworth DW
J Biomech Eng; 2015 Mar; 137(3):. PubMed ID: 25363041
[TBL] [Abstract][Full Text] [Related]
40. High complication rate after biplanar open wedge high tibial osteotomy stabilized with a new spacer plate (Position HTO plate) without bone substitute.
Schröter S; Gonser CE; Konstantinidis L; Helwig P; Albrecht D
Arthroscopy; 2011 May; 27(5):644-52. PubMed ID: 21663721
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]