These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 29393928)

  • 1. Erratum: Preclinical evaluation of the effect of the combined use of the Ethicon Securestrap
    Med Devices (Auckl); 2018; 11():37. PubMed ID: 29393928
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Preclinical evaluation of the effect of the combined use of the Ethicon Securestrap
    Sutton N; MacDonald MH; Lombard J; Ilie B; Hinoul P; Granger DA
    Med Devices (Auckl); 2018; 11():1-9. PubMed ID: 29296101
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical and Patient-Reported Outcomes after Absorbable Strap Fixation for Ventral Hernia Repair.
    Bougard H; Bringman S; Hope WW; Redan JA; Doerhoff C; Chudy M; Romanowski C; Jones PC
    Surg Technol Int; 2017 Dec; 31():83-92. PubMed ID: 29315451
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Time Savings and Surgery Task Load Reduction in Open Intraperitoneal Onlay Mesh Fixation Procedure.
    Roy S; Hammond J; Panish J; Shnoda P; Savidge S; Wilson M
    ScientificWorldJournal; 2015; 2015():340246. PubMed ID: 26240834
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of Mesh Fixation Techniques in Elective Laparoscopic Repair of Incisional Hernia-ReliaTack™ v ProTack™ (TACKoMesh) - A double-blind randomised controlled trial.
    Sheen AJ; Pilkington JJ; Baltatzis M; Tyurkylmaz A; Stathakis P; Jamdar S; Siriwardena AK
    BMC Surg; 2018 Jul; 18(1):46. PubMed ID: 29996841
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biomechanical and histological evaluation of abdominal wall compliance with intraperitoneal onlay mesh implants in rabbits: a comparison of six different state-of-the-art meshes.
    Konerding MA; Chantereau P; Delventhal V; Holste JL; Ackermann M
    Med Eng Phys; 2012 Sep; 34(7):806-16. PubMed ID: 21992970
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Repair of primary and incisional hernias using composite mesh fixed with absorbable tackers: preliminary experience of a laparoscopic approach with a newly designed mesh in 29 cases.
    Agresta F; Marzetti A; Vigna S; Prando D; Porfidia R; Di Saverio S
    Updates Surg; 2017 Dec; 69(4):493-497. PubMed ID: 28409440
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of Recurrence Rates in Obese and Non-Obese Patients Undergoing Ventral Hernia Repair with Lighter-Weight, Partially Absorbable Mesh.
    Tollens T; Speybrouck S; Devroe K; Terry C; Alevoet C; Divilio LT; Patel B; Vanrykel JP
    Surg Technol Int; 2011 Dec; 21():140-3. PubMed ID: 22504983
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of mesh fixation devices for laparoscopic ventral hernia repair: an experimental study on human anatomic specimens.
    Chan YW; Sow Z; Lukic D; Monschein M; Calek E; Pretterklieber M; Hollinsky C
    Surg Endosc; 2018 Jul; 32(7):3158-3163. PubMed ID: 29340814
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Lightweight polypropylene mesh fixation in laparoscopic incisional hernia repair.
    Cavallaro G; Campanile FC; Rizzello M; Greco F; Iorio O; Iossa A; Silecchia G
    Minim Invasive Ther Allied Technol; 2013 Sep; 22(5):283-7. PubMed ID: 23808370
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of fixation devices on postoperative pain after laparoscopic ventral hernia repair: a randomized clinical trial of permanent tacks, absorbable tacks, and synthetic glue.
    Harsløf S; Krum-Møller P; Sommer T; Zinther N; Wara P; Friis-Andersen H
    Langenbecks Arch Surg; 2018 Jun; 403(4):529-537. PubMed ID: 29799075
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Initial Experience with a New Macroporous Partially Absorbable Mesh: Introducing Ultrapro® Advanced™.
    Handojo K; Meylemans D; Devroe K; Vermeiren K; Aelvoet C; Tollens T
    Surg Technol Int; 2016 Apr; 28():125-30. PubMed ID: 27042785
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Titanium versus absorbable tacks comparative study (TACS): a multicenter, non-inferiority prospective evaluation during laparoscopic repair of ventral and incisional hernia: study protocol for randomized controlled trial.
    Silecchia G; Cavallaro G; Raparelli L; Olmi S; Baldazzi G; Campanile FC
    Trials; 2015 Jun; 16():249. PubMed ID: 26037907
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Laparoscopic transabdominal preperitoneal (TAPP) groin hernia repair using n-butyl-2-cyanoacrylate (Liquiband®Fix8™) for mesh fixation and peritoneal closure: learning experience during introduction into clinical practice.
    Wilson P; Hickey L
    Hernia; 2019 Jun; 23(3):601-613. PubMed ID: 30506242
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The use of cyanoacrylate sealant as simple mesh fixation in laparoscopic ventral hernia repair: a large animal evaluation.
    Reynvoet E; Van Cleven S; Van Overbeke I; Chiers K; De Baets P; Troisi R; Berrevoet F
    Hernia; 2015 Aug; 19(4):661-70. PubMed ID: 25644486
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Laparoscopic ventral hernia repair with composite mesh: Analysis of risk factors for recurrence in 185 patients with 5 years follow-up.
    Nardi M; Millo P; Brachet Contul R; Lorusso R; Usai A; Grivon M; Persico F; Ponte E; Bocchia P; Razzi S
    Int J Surg; 2017 Apr; 40():38-44. PubMed ID: 28219819
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Assessing the GRIP of Ventral Hernia Repair: How to Securely Fasten DIS Classified Meshes.
    Kallinowski F; Harder F; Gutjahr D; Raschidi R; Silva TG; Vollmer M; Nessel R
    Front Surg; 2017; 4():78. PubMed ID: 29404336
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Introducing the Proceed Ventral Patch as a new device in surgical management of umbilical and small ventral hernias: preliminary results.
    Tollens T; Struyve D; Aelvoet C; Vanrijkel JP
    Surg Technol Int; 2010 Apr; 19():99-103. PubMed ID: 20437352
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Recurrence rate after absorbable tack fixation of mesh in laparoscopic incisional hernia repair.
    Christoffersen MW; Brandt E; Helgstrand F; Westen M; Rosenberg J; Kehlet H; Strandfelt P; Bisgaard T
    Br J Surg; 2015 Apr; 102(5):541-7. PubMed ID: 25703637
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Polypropelene-mesh properties and type of anchoring do not influence strength of parietal ingrowth.
    Harsløf S; Zinther N; Harsløf T; Danielsen C; Wara P; Friis-Andersen H
    Langenbecks Arch Surg; 2017 Nov; 402(7):1047-1054. PubMed ID: 28733925
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.