These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 29399011)

  • 21. [Objective and quantitative study on the effect of lossy JPEG2000 compression of nuclear medicine image].
    Zhou L; Su X; Kuang A; Li L; Chai L
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2007 Oct; 24(5):1027-30, 1044. PubMed ID: 18027689
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Prediction of perceptible artifacts in JPEG2000 compressed abdomen CT images using a perceptual image quality metric.
    Kim B; Lee KH; Kim KJ; Mantiuk R; Bajpai V; Kim TJ; Kim YH; Yoon CJ; Hahn S
    Acad Radiol; 2008 Mar; 15(3):314-25. PubMed ID: 18280929
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The effect of JPEG2000 compression on detection of skull fractures.
    McEntee MF; Nikolovski I; Bourne R; Pietrzyk MW; Evanoff MG; Brennan PC; Tay KL
    Acad Radiol; 2013 Jun; 20(6):712-20. PubMed ID: 23664399
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Subjective Assessment of Objective Image Quality Metrics Range Guaranteeing Visually Lossless Compression.
    Afnan ; Ullah F; Yaseen ; Lee J; Jamil S; Kwon OJ
    Sensors (Basel); 2023 Jan; 23(3):. PubMed ID: 36772337
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Quality of compressed medical images.
    Shiao YH; Chen TJ; Chuang KS; Lin CH; Chuang CC
    J Digit Imaging; 2007 Jun; 20(2):149-59. PubMed ID: 17318703
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Digital image compression in dermatology: format comparison.
    Guarneri F; Vaccaro M; Guarneri C
    Telemed J E Health; 2008 Sep; 14(7):666-70. PubMed ID: 18817495
    [TBL] [Abstract][Full Text] [Related]  

  • 27. JPEG2000 still image coding quality.
    Chen TJ; Lin SC; Lin YC; Cheng RG; Lin LH; Wu W
    J Digit Imaging; 2013 Oct; 26(5):866-74. PubMed ID: 23589187
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Impact of lossy image compression on accuracy of caries detection in digital images taken with a storage phosphor system.
    Wenzel A; Gotfredsen E; Borg E; Gröndahl HG
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 1996 Mar; 81(3):351-5. PubMed ID: 8653470
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Effect of image compression and scaling on automated scoring of immunohistochemical stainings and segmentation of tumor epithelium.
    Konsti J; Lundin M; Linder N; Haglund C; Blomqvist C; Nevanlinna H; Aaltonen K; Nordling S; Lundin J
    Diagn Pathol; 2012 Mar; 7():29. PubMed ID: 22436596
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Evaluation of compressed lung CT image quality using quantitative analysis.
    Yamamoto S; Johkoh T; Mihara N; Umeda T; Azuma M; Nakanishi S; Narumi Y; Naito H; Nakamura H
    Radiat Med; 2001; 19(6):321-9. PubMed ID: 11837585
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Application study of JPEG2000 image compression in nuclear medicine].
    Zhou L; Su X; Qin W; Li L; Kuang A; Mo T
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Feb; 23(1):52-5. PubMed ID: 16532809
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Optimized JPEG 2000 Compression for Efficient Storage of Histopathological Whole-Slide Images.
    Helin H; Tolonen T; Ylinen O; Tolonen P; Näpänkangas J; Isola J
    J Pathol Inform; 2018; 9():20. PubMed ID: 29910969
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A compression and transmission scheme of computer tomography images for telemedicine based on JPEG2000.
    Varela JR; Tahoces PG; Souto M; Vidal JJ
    Telemed J E Health; 2004; 10 Suppl 2():S-40-4. PubMed ID: 23570212
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A Block Adaptive Near-Lossless Compression Algorithm for Medical Image Sequences and Diagnostic Quality Assessment.
    Sharma U; Sood M; Puthooran E
    J Digit Imaging; 2020 Apr; 33(2):516-530. PubMed ID: 31659588
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Improving diagnostic quality of MR images through controlled lossy compression using SPIHT.
    Choong MK; Logeswaran R; Bister M
    J Med Syst; 2006 Jun; 30(3):139-43. PubMed ID: 16848126
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Near-lossless Compression of Tc-99 m DMSA Scan Images Using Discrete Cosine Transformation.
    Yadav P; Pandey AK; Chaudhary J; Sharma PD; Jaleel J; Baghel V; Patel C; Kumar R
    Indian J Nucl Med; 2023; 38(3):231-238. PubMed ID: 38046967
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Quality degradation in lossy wavelet image compression.
    Chen TJ; Chuang KS; Wu J; Chen SC; Hwang IM; Jan ML
    J Digit Imaging; 2003 Jun; 16(2):210-5. PubMed ID: 14517721
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Restoration of lossy compressed noisy images.
    Al-Shaykh OK; Mersereau RM
    IEEE Trans Image Process; 1999; 8(10):1348-60. PubMed ID: 18267407
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Lossy 3D JPEG2000 compression of abdominal CT images in patients with acute abdominal complaints: effect of compression ratio on diagnostic confidence and accuracy.
    Ringl H; Schernthaner R; Sala E; El-Rabadi K; Weber M; Schima W; Herold CJ; Dixon AK
    Radiology; 2008 Aug; 248(2):476-84. PubMed ID: 18641251
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Oncologic image compression using both wavelet and masking techniques.
    Yin FF; Gao Q
    Med Phys; 1997 Dec; 24(12):2038-42. PubMed ID: 9434988
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.