BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

230 related articles for article (PubMed ID: 29402081)

  • 21. Zwitterions for impedance spectroscopy: The new buffers in town.
    Anand S; Swami P; Goel G; Gupta S
    Anal Chim Acta; 2021 Jun; 1166():338547. PubMed ID: 34022999
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Monitoring Single S. cerevisiae Cells with Multifrequency Electrical Impedance Spectroscopy in an Electrode-Integrated Microfluidic Device.
    Zhu Z; Geng Y; Wang Y
    Methods Mol Biol; 2021; 2189():105-118. PubMed ID: 33180297
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparative study of separation between ex vivo prostatic malignant and benign tissue using electrical impedance spectroscopy and electrical impedance tomography.
    Murphy EK; Mahara A; Khan S; Hyams ES; Schned AR; Pettus J; Halter RJ
    Physiol Meas; 2017 Jun; 38(6):1242-1261. PubMed ID: 28282026
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A review of impedance measurements of whole cells.
    Xu Y; Xie X; Duan Y; Wang L; Cheng Z; Cheng J
    Biosens Bioelectron; 2016 Mar; 77():824-36. PubMed ID: 26513290
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Single cell studies of mouse embryonic stem cell (mESC) differentiation by electrical impedance measurements in a microfluidic device.
    Zhou Y; Basu S; Laue E; Seshia AA
    Biosens Bioelectron; 2016 Jul; 81():249-258. PubMed ID: 26963790
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Impedance spectroscopy with field-effect transistor arrays for the analysis of anti-cancer drug action on individual cells.
    Susloparova A; Koppenhöfer D; Vu XT; Weil M; Ingebrandt S
    Biosens Bioelectron; 2013 Feb; 40(1):50-6. PubMed ID: 22795530
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Effects of lead exposure on blood electrical impedance spectroscopy of mice.
    Yang B; Xu J; Hu S; You B; Ma Q
    Biomed Eng Online; 2021 Oct; 20(1):99. PubMed ID: 34620171
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A Multimodality Electrochemical and Impedance Spectroscopy System-on-a-Chip With Temperature Sensing and Impedance-Boosting Techniques.
    Lin YJ; Liu WC; Huang YC; Huang YJ; Yeh YH; Chang MH; Lin SP; Liao YC; Liao YT
    IEEE Trans Biomed Circuits Syst; 2023 Aug; 17(4):857-871. PubMed ID: 37339024
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Recent Advances in Electrical Impedance Sensing Technology for Single-Cell Analysis.
    Zhang Z; Huang X; Liu K; Lan T; Wang Z; Zhu Z
    Biosensors (Basel); 2021 Nov; 11(11):. PubMed ID: 34821686
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A Novel Approach to Monitor the Concentration of Phosphate Buffers in the Range of 1 M to 0.1 M Using a Silicon-Based Impedance Sensor.
    Bhat VJ; Blaschke D; Müller E; Ehricht R; Schmidt H
    Biosensors (Basel); 2023 Aug; 13(9):. PubMed ID: 37754075
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Toxicity assessment of biological suspensions using the dielectric impedance spectroscopy technique.
    Muñoz S; Sebastián JL; Antoranz P; García-Cambero JP; Sanchis-Otero A
    Int J Radiat Biol; 2018 Oct; 94(10):944-950. PubMed ID: 29431558
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Electrical impedance spectroscopy for prostate cancer diagnosis.
    Mishra V; Bouayad H; Schned A; Heaney J; Halter RJ
    Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():3258-61. PubMed ID: 23366621
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Dielectric characterization of costal cartilage chondrocytes.
    Stacey MW; Sabuncu AC; Beskok A
    Biochim Biophys Acta; 2014 Jan; 1840(1):146-52. PubMed ID: 24016606
    [TBL] [Abstract][Full Text] [Related]  

  • 34. On-Chip Impedance for Quantifying Parasitic Voltages During AC Electrokinetic Trapping.
    Farmehini V; Varhue W; Salahi A; Hyler AR; Cemazar J; V Davalos R; Swami NS
    IEEE Trans Biomed Eng; 2020 Jun; 67(6):1664-1671. PubMed ID: 31545705
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Dielectric spectroscopy of red blood cells in sickle cell disease.
    Liu J; Qiang Y; Du E
    Electrophoresis; 2021 Mar; 42(5):667-675. PubMed ID: 33314275
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Interpulse multifrequency electrical impedance measurements during electroporation of adherent differentiated myotubes.
    García-Sánchez T; Azan A; Leray I; Rosell-Ferrer J; Bragós R; Mir LM
    Bioelectrochemistry; 2015 Oct; 105():123-35. PubMed ID: 26123676
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Dielectric spectroscopy in a micromachined flow cytometer: theoretical and practical considerations.
    Gawad S; Cheung K; Seger U; Bertsch A; Renaud P
    Lab Chip; 2004 Jun; 4(3):241-51. PubMed ID: 15159786
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Dielectrophoretic and Electrical Impedance Differentiation of Cancerous Cells Based on Biophysical Phenotype.
    Turcan I; Caras I; Schreiner TG; Tucureanu C; Salageanu A; Vasile V; Avram M; Tincu B; Olariu MA
    Biosensors (Basel); 2021 Oct; 11(10):. PubMed ID: 34677357
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Biophysical phenotyping of single cells using a differential multiconstriction microfluidic device with self-aligned 3D electrodes.
    Yang D; Zhou Y; Zhou Y; Han J; Ai Y
    Biosens Bioelectron; 2019 May; 133():16-23. PubMed ID: 30903937
    [TBL] [Abstract][Full Text] [Related]  

  • 40. All electronic approach for high-throughput cell trapping and lysis with electrical impedance monitoring.
    Ameri SK; Singh PK; Dokmeci MR; Khademhosseini A; Xu Q; Sonkusale SR
    Biosens Bioelectron; 2014 Apr; 54():462-7. PubMed ID: 24315878
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.