These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 29404891)

  • 1. Assessment of changes in blood glucose concentration with intravascular microdialysis.
    Fischer MO; Gouëzel C; Fradin S; Saplacan V; Gérard JL; Fellahi JL; Hanouz JL
    J Clin Monit Comput; 2018 Dec; 32(6):1135-1142. PubMed ID: 29404891
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Assessment of changes in lactate concentration with intravascular microdialysis during high-risk cardiac surgery using the trend interchangeability method.
    Gouëzel C; Lorne E; Bonnet V; Fradin S; Saplacan V; Gérard JL; Hanouz JL; Fellahi JL; Fischer MO;
    Br J Anaesth; 2017 Dec; 119(6):1110-1117. PubMed ID: 29028910
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of a continuous blood glucose monitoring system using a central venous catheter with an integrated microdialysis function.
    Schierenbeck F; Öwall A; Franco-Cereceda A; Liska J
    Diabetes Technol Ther; 2013 Jan; 15(1):26-31. PubMed ID: 23137021
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of a continuous blood glucose monitoring system using central venous microdialysis.
    Schierenbeck F; Franco-Cereceda A; Liska J
    J Diabetes Sci Technol; 2012 Nov; 6(6):1365-71. PubMed ID: 23294781
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Continuous Monitoring of Lactate Using Intravascular Microdialysis in High-Risk Cardiac Surgery: A Prospective Observational Study.
    Lenkin PI; Smetkin AA; Hussain A; Lenkin AI; Paromov KV; Ushakov AA; Krygina MM; Kuzkov VV; Kirov MY
    J Cardiothorac Vasc Anesth; 2017 Feb; 31(1):37-44. PubMed ID: 27554234
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Introducing intravascular microdialysis for continuous lactate monitoring in patients undergoing cardiac surgery: a prospective observational study.
    Schierenbeck F; Nijsten MW; Franco-Cereceda A; Liska J
    Crit Care; 2014 Mar; 18(2):R56. PubMed ID: 24684807
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Continuous on-line glucose measurement by microdialysis in a central vein. A pilot study.
    Blixt C; Rooyackers O; Isaksson B; Wernerman J
    Crit Care; 2013 May; 17(3):R87. PubMed ID: 23663747
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of intravascular microdialysis for continuous blood glucose monitoring in hypoglycemia: an animal model.
    Schierenbeck F; Wallin M; Franco-Cereceda A; Liska J
    J Diabetes Sci Technol; 2014 Jul; 8(4):839-44. PubMed ID: 24876424
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accuracy of 2 Different Continuous Glucose Monitoring Systems in Patients Undergoing Cardiac Surgery.
    Schierenbeck F; Franco-Cereceda A; Liska J
    J Diabetes Sci Technol; 2017 Jan; 11(1):108-116. PubMed ID: 27257168
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Serial lactate measurements using microdialysis of interstitial fluid do not correlate with plasma lactate in children after cardiac surgery.
    van den Heuvel I; Vlasselaers D; Wouters PJ; Milants I; Ellger B; Vanhorebeek I; Van den Berghe G
    Pediatr Crit Care Med; 2009 Jan; 10(1):66-70. PubMed ID: 19057429
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Intravascular microdialysis as a method for measuring glucose and lactate during and after cardiac surgery.
    Möller F; Liska J; Eidhagen F; Franco-Cereceda A
    J Diabetes Sci Technol; 2011 Sep; 5(5):1099-107. PubMed ID: 22027302
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of the accuracy of a microdialysis-based glucose sensor during insulin-induced hypoglycemia, its recovery, and post-hypoglycemic hyperglycemia in humans.
    Rossetti P; Porcellati F; Fanelli CG; Bolli GB
    Diabetes Technol Ther; 2006 Jun; 8(3):326-37. PubMed ID: 16800754
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intraoperative muscle and fat metabolism in diabetic patients during coronary artery bypass grafting surgery: a parallel microdialysis and organ balance study.
    Szabó Z; Andersson RG; Arnqvist HJ
    Br J Anaesth; 2009 Aug; 103(2):166-72. PubMed ID: 19454546
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Feasibility and precision of subcutaneous continuous glucose monitoring in patients undergoing CABG surgery.
    Aust H; Dinges G; Nardi-Hiebl S; Koch T; Lattermann R; Schricker T; Eberhart LH
    J Cardiothorac Vasc Anesth; 2014 Oct; 28(5):1264-72. PubMed ID: 25037649
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Inaccuracy of Venous Point-of-Care Glucose Measurements in Critically Ill Patients: A Cross-Sectional Study.
    Pereira AJ; Corrêa TD; de Almeida FP; Deliberato RO; Lobato Mdos S; Akamine N; Silva E; Cavalcanti AB
    PLoS One; 2015; 10(6):e0129568. PubMed ID: 26067093
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Point and trend accuracy of a continuous intravenous microdialysis-based glucose-monitoring device in critically ill patients: a prospective study.
    Leopold JH; van Hooijdonk RTM; Boshuizen M; Winters T; Bos LD; Abu-Hanna A; Hoek AMT; Fischer JC; van Dongen-Lases EC; Schultz MJ
    Ann Intensive Care; 2016 Dec; 6(1):68. PubMed ID: 27436191
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The Ability of esCCO and ECOM Monitors to Measure Trends in Cardiac Output During Alveolar Recruitment Maneuver After Cardiac Surgery: A Comparison with the Pulmonary Thermodilution Method.
    Thonnerieux M; Alexander B; Binet C; Obadia JF; Bastien O; Desebbe O
    Anesth Analg; 2015 Aug; 121(2):383-91. PubMed ID: 25902321
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Continuous glucose monitoring by intravenous microdialysis: influence of membrane length and dialysis flow rate.
    Rooyackers O; Blixt C; Mattsson P; Wernerman J
    Acta Anaesthesiol Scand; 2013 Feb; 57(2):214-9. PubMed ID: 23075419
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Accuracy of blood glucose measurements using the NOVA StatStrip® glucometer during cardiac surgery: a prospective observational study.
    Nakadate Y; Sato H; Roque P; Sato T; Matsukawa T; Wykes L; Kawakami A; Schricker T
    Can J Anaesth; 2019 Aug; 66(8):943-952. PubMed ID: 30895515
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Continuous noninvasive hemoglobin monitoring during complex spine surgery.
    Berkow L; Rotolo S; Mirski E
    Anesth Analg; 2011 Dec; 113(6):1396-402. PubMed ID: 21965372
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.