BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

225 related articles for article (PubMed ID: 29406327)

  • 1. Validation of the iHealth ambulatory blood pressure monitor in adults according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization standard.
    Kollias A; Ntineri A; Kyriakoulis KG; Stambolliu E; Stergiou GS
    Blood Press Monit; 2018 Apr; 23(2):115-116. PubMed ID: 29406327
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Validation of the professional device for blood pressure measurement Microlife WatchBP Office in adults and children according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization standard.
    Kollias A; Ntineri A; Kyriakoulis KG; Stambolliu E; Lagou S; Boubouchairopoulou N; Stergiou GS
    Blood Press Monit; 2018 Apr; 23(2):112-114. PubMed ID: 29239866
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validation of the YuWell YE680B upper-arm blood pressure monitor in adults according to the ANSI/AAMI/ISO 81060-2: 2013 standard.
    Huang JF; Zhang W; Li Y; Wang JG
    Blood Press Monit; 2019 Dec; 24(6):315-318. PubMed ID: 31577550
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Validation of the Raycome model M2 ambulatory blood pressure monitor in the general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard (ISO 81060-2:2018).
    Yang S; Zhou Z; Miao H; Zhang H; Zhou Q; Zhai M; Zhang Y
    Blood Press Monit; 2024 Jun; 29(3):161-165. PubMed ID: 38390625
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Validation of the InBody BP170 oscillometric home blood pressure monitor in general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard.
    Kollias A; Anagnostopoulos I; Gravvani A; Stambolliu E; Bountzona I; Menti A; Stergiou GS
    Blood Press Monit; 2020 Feb; 25(1):50-52. PubMed ID: 31633518
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Validation of the RBP-9801 oscillometric blood pressure monitor in the general population according to the association for the Advancement of Medical Instrumentation/European Society of Hypertension/ International Organization for Standardization Universal Standard.
    Yang S; Zhou Z; Miao H; Zhou Q; Zhai M; Zhang Y
    J Clin Hypertens (Greenwich); 2024 Jun; 26(6):703-707. PubMed ID: 38650108
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Validation of Omron HEM-7600T, a wearable device for monitoring blood pressure, according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization 81060-2:2013 protocol in the general population without arrhythmias.
    Takahashi H; Saito K; Hishiki Y
    Blood Press Monit; 2021 Apr; 26(2):156-159. PubMed ID: 33577185
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Validation of the InBody BPBIO250 oscillometric blood pressure monitor for professional office use in general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard.
    Kollias A; Gravvani A; Anagnostopoulos I; Kyriakoulis KG; Bountzona I; Menti A; Stergiou GS
    Blood Press Monit; 2020 Apr; 25(2):115-117. PubMed ID: 31913149
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Validation of the YuWell YE660D oscillometric upper-arm blood pressure monitor for clinic and home in general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard (International Organization for Standardization 81060-2:2018) and the International Organization for Standardization Amendment 1. 2020.
    Zhang HJ; Peng Y; Zhang J; Zhang J; Teng LN; Zhang SJ; Zhou DJ; Long MZ
    Blood Press Monit; 2023 Oct; 28(5):276-279. PubMed ID: 37382148
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Validation of Omron HEM-9200T, a home blood pressure monitoring device for the upper arm, according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization 81060-2:2013 protocol.
    Takahashi H; Saito K; Yakura N
    J Hum Hypertens; 2022 Apr; 36(4):416-419. PubMed ID: 33837291
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Validation of the automated oscillometric upper-arm cuff home blood pressure monitor AVITA BPM82 in a general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard.
    Menti A; Ntousopoulos V; Theodosiadi A; Stathopoulou P; Kollias A; Stergiou GS
    Blood Press Monit; 2024 Apr; 29(2):89-92. PubMed ID: 37937605
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Validation of the QMon-20 oscillometric blood pressure monitor for professional office use in the general population according to the ANSI/ESH/ISO 81060-2:2018 protocol.
    Rico-Martín S; Sánchez-Bacaicoa M; Calderón-García JF; Labrador-Gómez PJ; De Nicolás Jiménez JM; Villa-Rincón J; Robles NR; Guijarro C; Iammarino C; Rodilla-Salas E; Sánchez Muñoz-Torrero JF
    Blood Press Monit; 2021 Oct; 26(5):393-395. PubMed ID: 34001760
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Validation of the oscillometric home blood pressure monitor Braun BUA4000 with wide-range cuff in a general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard.
    Ntousopoulos V; Ntineri A; Theodosiadi A; Stathopoulou P; Menti A; Kyriakoulis KG; Kollias A; Stergiou GS
    Blood Press Monit; 2024 Apr; 29(2):99-102. PubMed ID: 37997431
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Validation of the single-cuff oscillometric blood pressure monitor InBody BPBIO750 for public spaces according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard.
    Ntineri A; Prapa S; Bountzona I; Menti A; Stergiou GS
    Blood Press Monit; 2021 Apr; 26(2):146-148. PubMed ID: 33323723
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Validation of the AViTA BPM636 upper arm blood pressure monitor in adults and pregnant women according to the ANSI/AAMI/ISO 81060-2:2013.
    Lee CN; Wu CK; Huang IC
    Blood Press Monit; 2023 Aug; 28(4):215-220. PubMed ID: 37074406
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Validation of the EDAN SA-10 ambulatory blood pressure monitor in general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard.
    Wang B; Liu K; Li L; Yin S; Ren J
    Blood Press Monit; 2022 Aug; 27(4):276-279. PubMed ID: 35438083
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Validation of the ABPMpro ambulatory blood pressure monitor in the general population according to AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018).
    Roth B; Bothe TL; Patzak A; Pilz N
    Blood Press Monit; 2023 Jun; 28(3):158-162. PubMed ID: 37016982
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of Meditech ABPM-06 ambulatory blood pressure measuring device, according to the European Society of Hypertension, the British Hypertension Society and the International Organization for Standardization Protocol.
    Hermányi Z; Pokoly B; Visolyi G; Barna I
    Blood Press Monit; 2019 Aug; 24(4):208-211. PubMed ID: 31162148
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Validation of the RisingSun RS-651 Blood Pressure Monitor Based on Auscultation in Adults According to the ANSI/AAMI/ISO 81060-2:2013 Standard.
    She J; Guan X; Liu Y; Xiang H
    J Clin Hypertens (Greenwich); 2016 Dec; 18(12):1279-1283. PubMed ID: 27271472
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accuracy of the Withings BPM Connect Device for Self-Blood Pressure Measurements in General Population - Validation According to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard.
    Topouchian J; Zelveian P; Hakobyan Z; Gharibyan H; Asmar R
    Vasc Health Risk Manag; 2022; 18():191-200. PubMed ID: 35386428
    [TBL] [Abstract][Full Text] [Related]  