166 related articles for article (PubMed ID: 29406817)
1. Evaluation of Surgical Devices Using an Artificial Pediatric Thoracic Model: A Comparison Between Robot-Assisted Thoracoscopic Suturing Versus Conventional Video-Assisted Thoracoscopic Suturing.
Takazawa S; Ishimaru T; Harada K; Deie K; Hinoki A; Uchida H; Sugita N; Mitsuishi M; Iwanaka T; Fujishiro J
J Laparoendosc Adv Surg Tech A; 2018 May; 28(5):622-627. PubMed ID: 29406817
[TBL] [Abstract][Full Text] [Related]
2. Robot-assisted endoscopic airway reconstruction in rabbits, with the aim to perform robot-assisted thoracoscopic bronchoplasty in human subjects.
Waseda R; Ishikawa N; Oda M; Matsumoto I; Ohta Y; Inaki N; Hirano Y; Watanabe G
J Thorac Cardiovasc Surg; 2007 Oct; 134(4):989-95. PubMed ID: 17903519
[TBL] [Abstract][Full Text] [Related]
3. [A comparative study of Da Vinci robot system with video-assisted thoracoscopy in the surgical treatment of mediastinal lesions].
Ding R; Tong X; Xu S; Zhang D; Gao X; Teng H; Qu J; Wang S
Zhongguo Fei Ai Za Zhi; 2014 Jul; 17(7):557-62. PubMed ID: 25034587
[TBL] [Abstract][Full Text] [Related]
4. Video-based skill assessment of endoscopic suturing in a pediatric chest model and a box trainer.
Takazawa S; Ishimaru T; Harada K; Tsukuda Y; Sugita N; Mitsuishi M; Iwanaka T
J Laparoendosc Adv Surg Tech A; 2015 May; 25(5):445-53. PubMed ID: 25423170
[TBL] [Abstract][Full Text] [Related]
5. Pediatric Thoracoscopic Surgical Simulation Using a Rapid-Prototyped Chest Model and Motion Sensors Can Better Identify Skilled Surgeons Than a Conventional Box Trainer.
Takazawa S; Ishimaru T; Harada K; Deie K; Fujishiro J; Sugita N; Mitsuishi M; Iwanaka T
J Laparoendosc Adv Surg Tech A; 2016 Sep; 26(9):740-7. PubMed ID: 27599013
[TBL] [Abstract][Full Text] [Related]
6. Transferability of Virtual Reality, Simulation-Based, Robotic Suturing Skills to a Live Porcine Model in Novice Surgeons: A Single-Blind Randomized Controlled Trial.
Vargas MV; Moawad G; Denny K; Happ L; Misa NY; Margulies S; Opoku-Anane J; Abi Khalil E; Marfori C
J Minim Invasive Gynecol; 2017; 24(3):420-425. PubMed ID: 28027975
[TBL] [Abstract][Full Text] [Related]
7. Da Vinci robot-assisted system for thymectomy: experience of 55 patients in China.
Jun Y; Hao L; Demin L; Guohua D; Hua J; Yi S
Int J Med Robot; 2014 Sep; 10(3):294-9. PubMed ID: 24573969
[TBL] [Abstract][Full Text] [Related]
8. Evaluation of a robot-assisted video-assisted thoracoscopic surgery programme.
He Y; Coonar A; Gelvez-Zapata S; Sastry P; Page A
Exp Ther Med; 2014 Apr; 7(4):873-876. PubMed ID: 24669243
[TBL] [Abstract][Full Text] [Related]
9. Laparoscopic suturing and knot tying: a comparison of standard techniques to a mechanical assist device.
Bermas H; Fenoglio M; Haun W; Moore JT
JSLS; 2004; 8(2):187-9. PubMed ID: 15119668
[TBL] [Abstract][Full Text] [Related]
10. Initial experience of robot-assisted thoracoscopic surgery in China.
Huang J; Luo Q; Tan Q; Lin H; Qian L; Lin X
Int J Med Robot; 2014 Dec; 10(4):404-9. PubMed ID: 24782317
[TBL] [Abstract][Full Text] [Related]
11. Preliminary Study of Video-Based Pediatric Endoscopic Surgical Skill Assessment Using a Neonatal Esophageal Atresia/Tracheoesophageal Fistula Model.
Deie K; Ishimaru T; Takazawa S; Harada K; Sugita N; Mitsuishi M; Fujishiro J; Iwanaka T
J Laparoendosc Adv Surg Tech A; 2017 Jan; 27(1):76-81. PubMed ID: 27858521
[TBL] [Abstract][Full Text] [Related]
12. Effects of visual force feedback on robot-assisted surgical task performance.
Reiley CE; Akinbiyi T; Burschka D; Chang DC; Okamura AM; Yuh DD
J Thorac Cardiovasc Surg; 2008 Jan; 135(1):196-202. PubMed ID: 18179942
[TBL] [Abstract][Full Text] [Related]
13. Comparing robot-assisted thoracic surgical lobectomy with conventional video-assisted thoracic surgical lobectomy and wedge resection: results from a multihospital database (Premier).
Swanson SJ; Miller DL; McKenna RJ; Howington J; Marshall MB; Yoo AC; Moore M; Gunnarsson CL; Meyers BF
J Thorac Cardiovasc Surg; 2014 Mar; 147(3):929-37. PubMed ID: 24210834
[TBL] [Abstract][Full Text] [Related]
14. Comparison of robotic and laparoendoscopic single-site surgery systems in a suturing and knot tying task.
Eisenberg D; Vidovszky TJ; Lau J; Guiroy B; Rivas H
Surg Endosc; 2013 Sep; 27(9):3182-6. PubMed ID: 23443484
[TBL] [Abstract][Full Text] [Related]
15. Is a robotic system really better than the three-dimensional laparoscopic system in terms of suturing performance?: comparison among operators with different levels of experience.
Park YS; Oo AM; Son SY; Shin DJ; Jung DH; Ahn SH; Park DJ; Kim HH
Surg Endosc; 2016 Apr; 30(4):1485-90. PubMed ID: 26139502
[TBL] [Abstract][Full Text] [Related]
16. Does transition from the da Vinci Si to Xi robotic platform impact single-docking technique for robot-assisted laparoscopic nephroureterectomy?
Patel MN; Aboumohamed A; Hemal A
BJU Int; 2015 Dec; 116(6):990-4. PubMed ID: 26123244
[TBL] [Abstract][Full Text] [Related]
17. Comparing the da Vinci si single console and dual console in teaching novice surgeons suturing techniques.
Crusco S; Jackson T; Advincula A
JSLS; 2014; 18(3):. PubMed ID: 25392618
[TBL] [Abstract][Full Text] [Related]
18. Minimally invasive thoracic surgery: robot-assisted versus video-assisted thoracoscopic surgery.
Zeng L; He T; Hu J
Wideochir Inne Tech Maloinwazyjne; 2023 Sep; 18(3):436-444. PubMed ID: 37868280
[TBL] [Abstract][Full Text] [Related]
19. Laparoscopic suturing evaluation among surgical residents.
Nguyen NT; Mayer KL; Bold RJ; Larson M; Foster S; Ho HS; Wolfe BM
J Surg Res; 2000 Sep; 93(1):133-6. PubMed ID: 10945954
[TBL] [Abstract][Full Text] [Related]
20. [Robotically and video-assisted thoracoscopic interruption of patent ductus arteriosus].
Miyaji K
Kyobu Geka; 2006 Jul; 59(8 Suppl):661-5. PubMed ID: 16910511
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]