These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 29414982)

  • 21. Ductility improvement due to martensite α' decomposition in porous Ti-6Al-4V parts produced by selective laser melting for orthopedic implants.
    Sallica-Leva E; Caram R; Jardini AL; Fogagnolo JB
    J Mech Behav Biomed Mater; 2016 Feb; 54():149-58. PubMed ID: 26458113
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Influence of cell shape on mechanical properties of Ti-6Al-4V meshes fabricated by electron beam melting method.
    Li SJ; Xu QS; Wang Z; Hou WT; Hao YL; Yang R; Murr LE
    Acta Biomater; 2014 Oct; 10(10):4537-47. PubMed ID: 24969664
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Tribological behavior of Ti6Al4V cellular structures produced by Selective Laser Melting.
    Bartolomeu F; Sampaio M; Carvalho O; Pinto E; Alves N; Gomes JR; Silva FS; Miranda G
    J Mech Behav Biomed Mater; 2017 May; 69():128-134. PubMed ID: 28068622
    [TBL] [Abstract][Full Text] [Related]  

  • 24. In vitro fibroblast and pre-osteoblastic cellular responses on laser surface modified Ti-6Al-4V.
    Chikarakara E; Fitzpatrick P; Moore E; Levingstone T; Grehan L; Higginbotham C; Vázquez M; Bagga K; Naher S; Brabazon D
    Biomed Mater; 2014 Dec; 10(1):015007. PubMed ID: 25546881
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Structural, mechanical and in vitro characterization of individually structured Ti-6Al-4V produced by direct laser forming.
    Hollander DA; von Walter M; Wirtz T; Sellei R; Schmidt-Rohlfing B; Paar O; Erli HJ
    Biomaterials; 2006 Mar; 27(7):955-63. PubMed ID: 16115681
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Osseointegration of three-dimensional designed titanium implants manufactured by selective laser melting.
    Shaoki A; Xu JY; Sun H; Chen XS; Ouyang J; Zhuang XM; Deng FL
    Biofabrication; 2016 Oct; 8(4):045014. PubMed ID: 27788123
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Effect of pore size on bone ingrowth into porous titanium implants fabricated by additive manufacturing: An in vivo experiment.
    Taniguchi N; Fujibayashi S; Takemoto M; Sasaki K; Otsuki B; Nakamura T; Matsushita T; Kokubo T; Matsuda S
    Mater Sci Eng C Mater Biol Appl; 2016 Feb; 59():690-701. PubMed ID: 26652423
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Compression deformation behavior of Ti-6Al-4V alloy with cellular structures fabricated by electron beam melting.
    Cheng XY; Li SJ; Murr LE; Zhang ZB; Hao YL; Yang R; Medina F; Wicker RB
    J Mech Behav Biomed Mater; 2012 Dec; 16():153-62. PubMed ID: 23182384
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [A preliminary study on the mechanical characteristics of the titanium scaffolds with three-dimensional mesh structure fabricated by electron beam melting].
    Yan RZ; Li YF; Wang C; Li RX; Liu ZW; Hu M
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2016 Nov; 51(11):656-660. PubMed ID: 27806757
    [No Abstract]   [Full Text] [Related]  

  • 30. Nanostructured severe plastic deformation processed titanium for orthodontic mini-implants.
    Serra G; Morais L; Elias CN; Semenova IP; Valiev R; Salimgareeva G; Pithon M; Lacerda R
    Mater Sci Eng C Mater Biol Appl; 2013 Oct; 33(7):4197-202. PubMed ID: 23910333
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Functionally graded Co-Cr-Mo coating on Ti-6Al-4V alloy structures.
    Vamsi Krishna B; Xue W; Bose S; Bandyopadhyay A
    Acta Biomater; 2008 May; 4(3):697-706. PubMed ID: 18054298
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Evaluation of biocompatibility of Ti-6Al-4V scaffolds fabricated by electron beam melting].
    Wang H; Zhao BJ; Yan RZ; Wang C; Luo CC; Hu M
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2016 Nov; 51(11):667-672. PubMed ID: 27806759
    [No Abstract]   [Full Text] [Related]  

  • 33. Microstructure and compression properties of 3D powder printed Ti-6Al-4V scaffolds with designed porosity: Experimental and computational analysis.
    Barui S; Chatterjee S; Mandal S; Kumar A; Basu B
    Mater Sci Eng C Mater Biol Appl; 2017 Jan; 70(Pt 1):812-823. PubMed ID: 27770959
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Revival of pure titanium for dynamically loaded porous implants using additive manufacturing.
    Wauthle R; Ahmadi SM; Amin Yavari S; Mulier M; Zadpoor AA; Weinans H; Van Humbeeck J; Kruth JP; Schrooten J
    Mater Sci Eng C Mater Biol Appl; 2015 Sep; 54():94-100. PubMed ID: 26046272
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A Study of the Structural Characteristics of Titanium Alloy Products Manufactured Using Additive Technologies by Combining the Selective Laser Melting and Direct Metal Deposition Methods.
    Samodurova M; Logachev I; Shaburova N; Samoilova O; Radionova L; Zakirov R; Pashkeev K; Myasoedov V; Trofimov E
    Materials (Basel); 2019 Oct; 12(19):. PubMed ID: 31597287
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Microstructure and mechanical behavior of Ti-6Al-4V produced by rapid-layer manufacturing, for biomedical applications.
    Murr LE; Quinones SA; Gaytan SM; Lopez MI; Rodela A; Martinez EY; Hernandez DH; Martinez E; Medina F; Wicker RB
    J Mech Behav Biomed Mater; 2009 Jan; 2(1):20-32. PubMed ID: 19627804
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Indirect Fabrication of Lattice Metals with Thin Sections Using Centrifugal Casting.
    Mun J; Ju J; Thurman J
    J Vis Exp; 2016 May; (111):. PubMed ID: 27214495
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Manufacturing of individual biodegradable bone substitute implants using selective laser melting technique.
    Lindner M; Hoeges S; Meiners W; Wissenbach K; Smeets R; Telle R; Poprawe R; Fischer H
    J Biomed Mater Res A; 2011 Jun; 97(4):466-71. PubMed ID: 21495168
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Improving the fatigue performance of porous metallic biomaterials produced by Selective Laser Melting.
    Van Hooreweder B; Apers Y; Lietaert K; Kruth JP
    Acta Biomater; 2017 Jan; 47():193-202. PubMed ID: 27717912
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Custom-made titanium devices as membranes for bone augmentation in implant treatment: Modeling accuracy of titanium products constructed with selective laser melting.
    Otawa N; Sumida T; Kitagaki H; Sasaki K; Fujibayashi S; Takemoto M; Nakamura T; Yamada T; Mori Y; Matsushita T
    J Craniomaxillofac Surg; 2015 Sep; 43(7):1289-95. PubMed ID: 26183658
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.