428 related articles for article (PubMed ID: 29424767)
1. Extracellular Vesicles from Human Liver Stem Cells Reduce Injury in an Ex Vivo Normothermic Hypoxic Rat Liver Perfusion Model.
Rigo F; De Stefano N; Navarro-Tableros V; David E; Rizza G; Catalano G; Gilbo N; Maione F; Gonella F; Roggio D; Martini S; Patrono D; Salizzoni M; Camussi G; Romagnoli R
Transplantation; 2018 May; 102(5):e205-e210. PubMed ID: 29424767
[TBL] [Abstract][Full Text] [Related]
2. Metabolic shift in liver: correlation between perfusion temperature and hypoxia inducible factor-1α.
Ferrigno A; Di Pasqua LG; Bianchi A; Richelmi P; Vairetti M
World J Gastroenterol; 2015 Jan; 21(4):1108-16. PubMed ID: 25632183
[TBL] [Abstract][Full Text] [Related]
3. Ex Vivo Normothermic Hypoxic Rat Liver Perfusion Model: An Experimental Setting for Organ Recondition and Pharmacological Intervention.
Rigo F; Navarro-Tableros V; De Stefano N; Calleri A; Romagnoli R
Methods Mol Biol; 2021; 2269():139-150. PubMed ID: 33687677
[TBL] [Abstract][Full Text] [Related]
4. Human liver stem cell-derived extracellular vesicles reduce injury in a model of normothermic machine perfusion of rat livers previously exposed to a prolonged warm ischemia.
De Stefano N; Navarro-Tableros V; Roggio D; Calleri A; Rigo F; David E; Gambella A; Bassino D; Amoroso A; Patrono D; Camussi G; Romagnoli R
Transpl Int; 2021 Sep; 34(9):1607-1617. PubMed ID: 34448268
[TBL] [Abstract][Full Text] [Related]
5. Normothermic machine perfusion reduces bile duct injury and improves biliary epithelial function in rat donor livers.
Op den Dries S; Karimian N; Westerkamp AC; Sutton ME; Kuipers M; Wiersema-Buist J; Ottens PJ; Kuipers J; Giepmans BN; Leuvenink HG; Lisman T; Porte RJ
Liver Transpl; 2016 Jul; 22(7):994-1005. PubMed ID: 26946466
[TBL] [Abstract][Full Text] [Related]
6. Combined liver-kidney perfusion enhances protective effects of normothermic perfusion on liver grafts from donation after cardiac death.
He X; Ji F; Zhang Z; Tang Y; Yang L; Huang S; Li W; Su Q; Xiong W; Zhu Z; Wang L; Lv L; Yao J; Zhang L; Zhang L; Guo Z
Liver Transpl; 2018 Jan; 24(1):67-79. PubMed ID: 29024427
[TBL] [Abstract][Full Text] [Related]
7. Hypothermic machine perfusion with metformin-University of Wisconsin solution for
Chai YC; Dang GX; He HQ; Shi JH; Zhang HK; Zhang RT; Wang B; Hu LS; Lv Y
World J Gastroenterol; 2017 Oct; 23(40):7221-7231. PubMed ID: 29142469
[TBL] [Abstract][Full Text] [Related]
8. Machine Perfusion at 20°C Prevents Ischemic Injury and Reduces Hypoxia-Inducible Factor-1α Expression During Rat Liver Preservation.
Berardo C; Di Pasqua LG; Siciliano V; Rizzo V; Richelmi P; Ferrigno A; Vairetti M
Ann Transplant; 2017 Sep; 22():581-589. PubMed ID: 28959005
[TBL] [Abstract][Full Text] [Related]
9. Protective role of normothermic machine perfusion during reduced-size liver transplantation in pigs.
Zhang ZB; Gao W; Shi Y; Liu L; Ma N; Chen J; Zhu ZJ
Liver Transpl; 2016 Jul; 22(7):968-78. PubMed ID: 27037634
[TBL] [Abstract][Full Text] [Related]
10. Activation of Fibrinolysis, But Not Coagulation, During End-Ischemic Ex Situ Normothermic Machine Perfusion of Human Donor Livers.
Karangwa SA; Burlage LC; Adelmeijer J; Karimian N; Westerkamp AC; Matton AP; van Rijn R; Wiersema-Buist J; Sutton ME; Op den Dries S; Lisman T; Porte RJ
Transplantation; 2017 Feb; 101(2):e42-e48. PubMed ID: 27941437
[TBL] [Abstract][Full Text] [Related]
11. Customized normothermic machine perfusion decreases ischemia-reperfusion injury compared with static cold storage in a porcine model of liver transplantation.
Riveros S; Marino C; Ochoa G; Soto D; Alegría L; Zenteno MJ; San Martín S; Brañes A; Achurra P; Rebolledo R
Artif Organs; 2023 Jan; 47(1):148-159. PubMed ID: 36007920
[TBL] [Abstract][Full Text] [Related]
12. Relationship between ischemia/reperfusion injury and the stimulus of fibrogenesis in an experimental model: comparison among different preservation solutions.
Camacho VR; de Fraga RS; Cerski CT; de Oliveira JR; Álvares-da-Silva MR
Transplant Proc; 2011 Dec; 43(10):3634-7. PubMed ID: 22172818
[TBL] [Abstract][Full Text] [Related]
13. Rewarming preservation by organ perfusion system for donation after cardiac death liver grafts in pigs.
Matsuno N; Obara H; Watanabe R; Iwata S; Kono S; Fujiyama M; Hirano T; Kanazawa H; Enosawa S
Transplant Proc; 2014 May; 46(4):1095-8. PubMed ID: 24815137
[TBL] [Abstract][Full Text] [Related]
14. End-ischemic machine perfusion reduces bile duct injury in donation after circulatory death rat donor livers independent of the machine perfusion temperature.
Westerkamp AC; Mahboub P; Meyer SL; Hottenrott M; Ottens PJ; Wiersema-Buist J; Gouw AS; Lisman T; Leuvenink HG; Porte RJ
Liver Transpl; 2015 Oct; 21(10):1300-11. PubMed ID: 26097213
[TBL] [Abstract][Full Text] [Related]
15. Pilot, Open, Randomized, Prospective Trial for Normothermic Machine Perfusion Evaluation in Liver Transplantation From Older Donors.
Ghinolfi D; Rreka E; De Tata V; Franzini M; Pezzati D; Fierabracci V; Masini M; Cacciatoinsilla A; Bindi ML; Marselli L; Mazzotti V; Morganti R; Marchetti P; Biancofiore G; Campani D; Paolicchi A; De Simone P
Liver Transpl; 2019 Mar; 25(3):436-449. PubMed ID: 30362649
[TBL] [Abstract][Full Text] [Related]
16. Novel strategy to decrease reperfusion injuries and improve function of cold-preserved livers using normothermic ex vivo liver perfusion machine.
Banan B; Xiao Z; Watson R; Xu M; Jia J; Upadhya GA; Mohanakumar T; Lin Y; Chapman W
Liver Transpl; 2016 Mar; 22(3):333-43. PubMed ID: 26439190
[TBL] [Abstract][Full Text] [Related]
17. Normothermic Machine Perfusion Protects Against Liver Ischemia-Reperfusion Injury During Reduced-Size Liver Transplantation in Pigs.
Zhang ZB; Gao W; Liu L; Shi Y; Ma N; Huai MS; Shen ZY
Ann Transplant; 2019 Jan; 24():9-17. PubMed ID: 30607000
[TBL] [Abstract][Full Text] [Related]
18. Bone marrow mesenchymal stem cells combine with normothermic machine perfusion to improve rat donor liver quality-the important role of hepatic microcirculation in donation after circulatory death.
Yang L; Cao H; Sun D; Hou B; Lin L; Shen ZY; Song HL
Cell Tissue Res; 2020 Aug; 381(2):239-254. PubMed ID: 32347385
[TBL] [Abstract][Full Text] [Related]
19. Oxygenated Hypothermic Machine Perfusion After Static Cold Storage Improves Hepatobiliary Function of Extended Criteria Donor Livers.
Westerkamp AC; Karimian N; Matton AP; Mahboub P; van Rijn R; Wiersema-Buist J; de Boer MT; Leuvenink HG; Gouw AS; Lisman T; Porte RJ
Transplantation; 2016 Apr; 100(4):825-35. PubMed ID: 26863473
[TBL] [Abstract][Full Text] [Related]
20. A Back-to-Base Experience of Human Normothermic Ex Situ Liver Perfusion: Does the Chill Kill?
Bral M; Dajani K; Leon Izquierdo D; Bigam D; Kneteman N; Ceresa CDL; Friend PJ; Shapiro AMJ
Liver Transpl; 2019 Jun; 25(6):848-858. PubMed ID: 30938039
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]