1. tcPCO2 electrode design, calibration and temperature gradient problems.
Severinghaus JW; Stafford M; Bradley AF
Acta Anaesthesiol Scand Suppl; 1978; 68():118-22. PubMed ID: 29431
[TBL] [Abstract][Full Text] [Related]
2. Effect of electrode temperatures on monitoring of transcutaneous carbon dioxide (TcPCO2) in prematures.
Vesterager P
Biotelem Patient Monit; 1982; 9(1):18-27. PubMed ID: 6809069
[TBL] [Abstract][Full Text] [Related]
3. Problems of calibration and stabilization of tcPO2 electrodes.
Severinghaus JW; Thunstrom A
Acta Anaesthesiol Scand Suppl; 1978; 68():68-72. PubMed ID: 279203
[TBL] [Abstract][Full Text] [Related]
4. Is continuous transcutaneous monitoring of PCO2 (TcPCO2) over 8 h reliable in adults?
Janssens JP; Perrin E; Bennani I; de Muralt B; Titelion V; Picaud C
Respir Med; 2001 May; 95(5):331-5. PubMed ID: 11392572
[TBL] [Abstract][Full Text] [Related]
5. Transcutaneous PCO2 electrode design with internal silver heat path.
Severinghaus JW; Bradley AF; Stafford MJ
Birth Defects Orig Artic Ser; 1979; 15(4):265-70. PubMed ID: 534705
[No Abstract] [Full Text] [Related]
6. Transcutaneous analysis of arterial PCO2.
Hazinski TA; Severinghaus JW
Med Instrum; 1982; 16(3):150-3. PubMed ID: 6810072
[TBL] [Abstract][Full Text] [Related]
7. The importance of an elevated skin temperature in transcutaneous oxygen tension measurement.
Al-Siaidy W; Hill DW
Birth Defects Orig Artic Ser; 1979; 15(4):149-65. PubMed ID: 534695
[TBL] [Abstract][Full Text] [Related]
8. Blood flow rate, temperature, oxygen tension and consumption in the skin of adults measured by a heated microcathode oxygen electrode.
Jaszczak P
Dan Med Bull; 1988 Aug; 35(4):322-34. PubMed ID: 3048920
[TBL] [Abstract][Full Text] [Related]
9. Calibration of a heated transcutaneous carbon dioxide electrode to reflect arterial carbon dioxide.
Monaco F; McQuitty JC; Nickerson BG
Am Rev Respir Dis; 1983 Mar; 127(3):322-4. PubMed ID: 6402964
[TBL] [Abstract][Full Text] [Related]
10. Transcutaneous pO2 electrode.
Vesterager P
Scand J Clin Lab Invest Suppl; 1977; 146():27-30. PubMed ID: 834956
[TBL] [Abstract][Full Text] [Related]
11. Comparison of the transcutaneous oxygen and carbon dioxide tension in different electrode locations during general anaesthesia.
Nishiyama T; Nakamura S; Yamashita K
Eur J Anaesthesiol; 2006 Dec; 23(12):1049-54. PubMed ID: 16824244
[TBL] [Abstract][Full Text] [Related]
12. Transcutaneous carbon dioxide and oxygen tension measured at different temperatures in healthy adults.
Wimberley PD; Grønlund Pedersen K; Olsson J; Siggaard-Andersen O
Clin Chem; 1985 Oct; 31(10):1611-5. PubMed ID: 3930089
[TBL] [Abstract][Full Text] [Related]
13. Use of transcutaneous oxygen and carbon dioxide tensions for assessing indices of gas exchange during exercise testing.
Carter R; Banham SW
Respir Med; 2000 Apr; 94(4):350-5. PubMed ID: 10845433
[TBL] [Abstract][Full Text] [Related]
14. Increasing arterial carbon dioxide tension: influence on transcutaneous carbon dioxide tension measurements.
Martin RJ; Beoglos A; Miller MJ; DiFiore JM; Robertson SS; Carlo WA
Pediatrics; 1988 May; 81(5):684-7. PubMed ID: 3128769
[TBL] [Abstract][Full Text] [Related]
15. International Federation of Clinical Chemistry (IFCC). Scientific Division. Committee on pH, Blood Gases and Electrolytes. Guidelines for transcutaneous PO2 and PCO2 measurement.
Winberley PD; Burnett RW; Covington AK; Maas AH; Mueller-Plathe O; Siggaard-Andersen O; Weisberg HF; Zijlstra WG
Ann Biol Clin (Paris); 1990; 48(1):39-43. PubMed ID: 2306025
[TBL] [Abstract][Full Text] [Related]
16. An improved sensor and a method for transcutaneous CO2 monitoring.
Beran AV; Shigezawa GY; Yeung HN; Huxtable RF
Acta Anaesthesiol Scand Suppl; 1978; 68():111-7. PubMed ID: 279192
[No Abstract] [Full Text] [Related]
17. Characteristics of non-aqueous electrolytes for transcutaneous oxygen electrodes.
Peabody JL; Willis MM; Severinghaus JW
Acta Anaesthesiol Scand Suppl; 1978; 68():49-54. PubMed ID: 279200
[TBL] [Abstract][Full Text] [Related]
18. Measurement of transcutaneous PCO2 in critically ill patients.
Rithalia SV; Ng YY; Tinker J
Resuscitation; 1982 Mar; 10(1):13-8. PubMed ID: 6291114
[TBL] [Abstract][Full Text] [Related]
19. Single electrochemical sensor for transcutaneous measurement of PO2 and PCO2.
Parker D; Delpy DT; Reynolds EO
Birth Defects Orig Artic Ser; 1979; 15(4):109-16. PubMed ID: 534689
[No Abstract] [Full Text] [Related]
20. Transcutaneous measurement of carbon dioxide tension: effect of sleep state in term infants.
Martin RJ; Herrell N; Pultusker M
Pediatrics; 1981 May; 67(5):622-5. PubMed ID: 6789297
[TBL] [Abstract][Full Text] [Related]