These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

209 related articles for article (PubMed ID: 29433516)

  • 41. Current status and critical reflections on implantable hearing aids.
    Hüttenbrink KB
    Am J Otol; 1999 Jul; 20(4):409-15. PubMed ID: 10431878
    [TBL] [Abstract][Full Text] [Related]  

  • 42. [Principles of energy sources of totally implantable hearing aids for inner ear hearing loss].
    Baumann JW; Leysieffer H
    HNO; 1998 Feb; 46(2):121-8. PubMed ID: 9556710
    [TBL] [Abstract][Full Text] [Related]  

  • 43. A new floating piezoelectric microphone for the implantable middle ear microphone in experimental studies.
    Jia XH; Gao N; Xu XD; Wu YZ; Kang HY; Chi FL
    Acta Otolaryngol; 2016 Dec; 136(12):1248-1254. PubMed ID: 27388506
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Measurement method for the assessment of transmission properties of implantable hearing aids.
    Winter M; Weber BP; Lenarz T
    Biomed Tech (Berl); 2002; 47 Suppl 1 Pt 2():726-7. PubMed ID: 12465286
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Microphone directionality, pre-emphasis filter, and wind noise in cochlear implants.
    Chung K; McKibben N
    J Am Acad Audiol; 2011 Oct; 22(9):586-600. PubMed ID: 22192604
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Speech quality evaluation of subcutaneously implanted microphone using in vivo experiment.
    Woo ST; Lee G; Jung ES; Lim HG; Seong KW; Lee JH; Kim MN; Cho JH
    Biomed Mater Eng; 2014; 24(6):3685-91. PubMed ID: 25227083
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Improving Cochlear Implant Performance in the Wind Through Spectral Masking Release: A Multi-microphone and Multichannel Strategy.
    Chung K
    Ear Hear; 2020; 41(2):420-432. PubMed ID: 31425361
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Speech perception comparisons using an implanted and an external microphone in existing cochlear implant users.
    Jenkins HA; Uhler K
    Otol Neurotol; 2012 Jan; 33(1):13-9. PubMed ID: 22158017
    [TBL] [Abstract][Full Text] [Related]  

  • 49. The Esteem System: a totally implantable hearing device.
    Maurer J; Savvas E
    Adv Otorhinolaryngol; 2010; 69():59-71. PubMed ID: 20610915
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Bioelectronic options for a totally implantable hearing device for partial and total hearing loss.
    Maniglia AJ; Murray G; Arnold JE; Ko WH
    Otolaryngol Clin North Am; 2001 Apr; 34(2):469-83. PubMed ID: 11382582
    [TBL] [Abstract][Full Text] [Related]  

  • 51. [Principle requirements for an electromechanical transducer for implantable hearing aids in inner ear hearing loss. I: Technical and audiologic aspects].
    Leysieffer H
    HNO; 1997 Oct; 45(10):775-86. PubMed ID: 9445850
    [TBL] [Abstract][Full Text] [Related]  

  • 52. The middle ear bioelectronic microphone for a totally implantable cochlear hearing device for profound and total hearing loss.
    Maniglia AJ; Abbass H; Azar T; Kane M; Amantia P; Garverick S; Ko WH; Frenz W; Falk T
    Am J Otol; 1999 Sep; 20(5):602-11. PubMed ID: 10503582
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Otologics active middle ear implants.
    Jenkins HA; Uhler K
    Otolaryngol Clin North Am; 2014 Dec; 47(6):967-78. PubMed ID: 25301507
    [TBL] [Abstract][Full Text] [Related]  

  • 54. State of the art on the development of the implantable hearing device for partial hearing loss.
    Maniglia AJ
    Otolaryngol Clin North Am; 1996 Apr; 29(2):225-43. PubMed ID: 8860922
    [TBL] [Abstract][Full Text] [Related]  

  • 55. [An implantable piezoelectric hearing aid transducer for inner ear hearing loss. I: Development of a prototype].
    Leysieffer H; Baumann JW; Müller G; Zenner HP
    HNO; 1997 Oct; 45(10):792-800. PubMed ID: 9445852
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Experimental study of an implantable fiber-optic microphone on human cadavers.
    Djinović Z; Pavelka R; Tomić M; Sprinzl G; Müller JG; Traxler H
    Hear Res; 2021 Oct; 410():108351. PubMed ID: 34551371
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Verification of improved patient outcomes with a partially implantable hearing aid, The SOUNDTEC direct hearing system.
    Roland PS; Shoup AG; Shea MC; Richey HS; Jones DB
    Laryngoscope; 2001 Oct; 111(10):1682-6. PubMed ID: 11801925
    [TBL] [Abstract][Full Text] [Related]  

  • 58. An Intracochlear Pressure Sensor as a Microphone for a Fully Implantable Cochlear Implant.
    Creighton FP; Guan X; Park S; Kymissis IJ; Nakajima HH; Olson ES
    Otol Neurotol; 2016 Dec; 37(10):1596-1600. PubMed ID: 27631834
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Totally Implantable Active Middle Ear Implants.
    Seidman MD; Janz TA; Shohet JA
    Otolaryngol Clin North Am; 2019 Apr; 52(2):297-309. PubMed ID: 30770176
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Restoration of hearing by hearing aids: conventional hearing aids - implantable hearing aids - cochlear implants - auditory brainstem implants.
    Leuwer R; Müller J
    GMS Curr Top Otorhinolaryngol Head Neck Surg; 2005; 4():Doc03. PubMed ID: 22073051
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.