These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 29435017)

  • 1. A novel ARMS-based assay for the quantification of
    Zhu Y; Guo Z; Liu Y; Zheng X; Yang G; Zheng G
    Oncol Lett; 2018 Mar; 15(3):2905-2912. PubMed ID: 29435017
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantification of plasma EGFR mutations in patients with lung cancers: Comparison of the performance of ARMS-Plus and droplet digital PCR.
    Wang L; Guo Q; Yu W; Qiao L; Zhao M; Zhang C; Hu X; Yang G; Xiong L; Lou J
    Lung Cancer; 2017 Dec; 114():31-37. PubMed ID: 29173762
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comprehensive analysis of EGFR T790M detection by ddPCR and ARMS-PCR and the effect of mutant abundance on the efficacy of osimertinib in NSCLC patients.
    Li Y; Xu Y; Wu X; He C; Liu Q; Wang F
    J Thorac Dis; 2019 Jul; 11(7):3004-3014. PubMed ID: 31463130
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Multiplex picoliter-droplet digital PCR for quantitative assessment of EGFR mutations in circulating cell-free DNA derived from advanced non-small cell lung cancer patients.
    Yu Q; Huang F; Zhang M; Ji H; Wu S; Zhao Y; Zhang C; Wu J; Wang B; Pan B; Zhang X; Guo W
    Mol Med Rep; 2017 Aug; 16(2):1157-1166. PubMed ID: 29067441
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Clinical value of droplet digital polymerase chain reaction method in detecting plasma circulating tumor deoxyribonucleic acid epidermal growth factor receptor mutations in advanced pulmonary adenocarcinoma patients].
    Ma L; Lü JL; Li K; Wang JH; Yang XJ; Li X; Zhang H; Zhang Q; Qin N; Zhang SC
    Zhonghua Yi Xue Za Zhi; 2018 Aug; 98(29):2336-2340. PubMed ID: 30107692
    [No Abstract]   [Full Text] [Related]  

  • 6. [Comparison of epidermal growth factor receptor (EGFR) gene T790M mutation by droplet digital PCR and Super-ARMS PCR in plasma ctDNA samples of non-small cell lung cancer patients with the resistance to EGFR-tyrosine kinase inhibitor].
    Cao ZY; Wu W; Hou LK; Zhang W; Gao CX; Wu CY; Zhang LP
    Zhonghua Bing Li Xue Za Zhi; 2018 Dec; 47(12):910-914. PubMed ID: 30522170
    [No Abstract]   [Full Text] [Related]  

  • 7. Picoliter-Droplet Digital Polymerase Chain Reaction-Based Analysis of Cell-Free Plasma DNA to Assess EGFR Mutations in Lung Adenocarcinoma That Confer Resistance to Tyrosine-Kinase Inhibitors.
    Seki Y; Fujiwara Y; Kohno T; Takai E; Sunami K; Goto Y; Horinouchi H; Kanda S; Nokihara H; Watanabe S; Ichikawa H; Yamamoto N; Kuwano K; Ohe Y
    Oncologist; 2016 Feb; 21(2):156-64. PubMed ID: 26768482
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A comparison of ARMS-Plus and droplet digital PCR for detecting EGFR activating mutations in plasma.
    Zhang X; Chang N; Yang G; Zhang Y; Ye M; Cao J; Xiong J; Han Z; Wu S; Shang L; Zhang J
    Oncotarget; 2017 Dec; 8(67):112014-112023. PubMed ID: 29340107
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Clinical Value of Droplet Digital PCR and Super-ARMS Detection of Epidermal Growth Factor Receptor Gene Mutation in Plasma Circulating Tumor DNA of Patients with Advanced Lung Adenocarcinoma].
    Cao Z; Wang J; Qin N; Li K; Lv J; Wang J; Yang X; Li X; Zhang H; Zhang Q; Long H; Shu C; Ma L; Zhang S
    Zhongguo Fei Ai Za Zhi; 2020 Feb; 23(2):84-90. PubMed ID: 32093452
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Establishment and validation of a novel droplet digital PCR assay for ultrasensitive detection and dynamic monitoring of EGFR mutations in peripheral blood samples of non-small-cell lung cancer patients.
    Tang C; Zhu L; Zhang L; Tan C; Peng Z; Liu B; Liu W; Hu H; Bai Y; Wang B; Lin L; Liang J; Li X; Guo Y; Liu Y
    Clin Chim Acta; 2020 Nov; 510():88-96. PubMed ID: 32645388
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of the Amplification Refractory Mutation System, Super Amplification Refractory Mutation System, and Droplet Digital PCR for T790 M Mutation Detection in Non-small Cell Lung Cancer after Failure of Tyrosine Kinase Inhibitor Treatment.
    Zhu L; Zhang S; Xun Y; Jiang Y; Xia B; Chen X; Wang L; Jiang H; Ma S
    Pathol Oncol Res; 2018 Oct; 24(4):843-851. PubMed ID: 28868565
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Detection of epidermal growth factor receptor gene mutations in different types of non-small cell lung cancer by droplet digital PCR and amplification refractory mutation system].
    Li R; Ye SB; He Y; Wang X; Wu N; Xia QY; Shen Q; Shi SS
    Zhonghua Bing Li Xue Za Zhi; 2017 Nov; 46(11):764-768. PubMed ID: 29136689
    [No Abstract]   [Full Text] [Related]  

  • 13. A Comparison of ddPCR and ARMS for detecting EGFR T790M status in ctDNA from advanced NSCLC patients with acquired EGFR-TKI resistance.
    Wang W; Song Z; Zhang Y
    Cancer Med; 2017 Jan; 6(1):154-162. PubMed ID: 28000387
    [TBL] [Abstract][Full Text] [Related]  

  • 14. EGFR Mutations in Cell-free Plasma DNA from Patients with Advanced Lung Adenocarcinoma: Improved Detection by Droplet Digital PCR.
    Buder A; Setinek U; Hochmair MJ; Schwab S; Kirchbacher K; Keck A; Burghuber OC; Pirker R; Filipits M
    Target Oncol; 2019 Apr; 14(2):197-203. PubMed ID: 30810887
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Association of mutant EGFR L858R and exon 19 concentration in circulating cell-free DNA using droplet digital PCR with response to EGFR-TKIs in NSCLC.
    Zhu YJ; Zhang HB; Liu YH; Zhu YZ; Chen J; Li Y; Bai JP; Liu LR; Qu YC; Qu X; Chen X; Zheng GJ
    Oncol Lett; 2017 Aug; 14(2):2573-2579. PubMed ID: 28789464
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Detection of epidermal growth factor receptor mutation in lung cancer by droplet digital polymerase chain reaction.
    Xu Q; Zhu Y; Bai Y; Wei X; Zheng X; Mao M; Zheng G
    Onco Targets Ther; 2015; 8():1533-41. PubMed ID: 26124670
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The detection of primary and secondary EGFR mutations using droplet digital PCR in patients with nonsmall cell lung cancer.
    Suryavanshi M; Mehta A; Panigrahi MK; Jaipuria J; Saifi M; Jain K; Kumar D; Verma H; Sharma SK; Batra U; Dutta K; Talwar V; Doval DC
    Lung India; 2018; 35(5):384-389. PubMed ID: 30168456
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of EGFR mutations in NSCLC with highly sensitive droplet digital PCR assays.
    Jiang XW; Liu W; Zhu XY; Xu XX
    Mol Med Rep; 2019 Jul; 20(1):593-603. PubMed ID: 31115577
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of droplet digital PCR and conventional quantitative PCR for measuring
    Zhang BO; Xu CW; Shao Y; Wang HT; Wu YF; Song YY; Li XB; Zhang Z; Wang WJ; Li LQ; Cai CL
    Exp Ther Med; 2015 Apr; 9(4):1383-1388. PubMed ID: 25780439
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Detection of Plasma EGFR Mutations in NSCLC Patients with a Validated ddPCR Lung cfDNA Assay.
    Guo QM; Wang L; Yu WJ; Qiao LH; Zhao MN; Hu XM; Sun YM; Ni S; Xu YH; Lou JT
    J Cancer; 2019; 10(18):4341-4349. PubMed ID: 31413754
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.