351 related articles for article (PubMed ID: 29435589)
1. Three-Dimensional Cataract Crystalline Lens Imaging With Swept-Source Optical Coherence Tomography.
de Castro A; Benito A; Manzanera S; Mompeán J; Cañizares B; Martínez D; Marín JM; Grulkowski I; Artal P
Invest Ophthalmol Vis Sci; 2018 Feb; 59(2):897-903. PubMed ID: 29435589
[TBL] [Abstract][Full Text] [Related]
2. Lens nuclear opacity quantitation with long-range swept-source optical coherence tomography: correlation to LOCS III and a Scheimpflug imaging-based grading system.
Chen D; Li Z; Huang J; Yu L; Liu S; Zhao YE
Br J Ophthalmol; 2019 Aug; 103(8):1048-1053. PubMed ID: 30315132
[TBL] [Abstract][Full Text] [Related]
3. Cataract quantification using swept-source optical coherence tomography.
Brás JEG; Sickenberger W; Hirnschall N; Findl O
J Cataract Refract Surg; 2018 Dec; 44(12):1478-1481. PubMed ID: 30392762
[TBL] [Abstract][Full Text] [Related]
4. Optical Coherence Tomography Based Estimates of Crystalline Lens Volume, Equatorial Diameter, and Plane Position.
Martinez-Enriquez E; Sun M; Velasco-Ocana M; Birkenfeld J; Pérez-Merino P; Marcos S
Invest Ophthalmol Vis Sci; 2016 Jul; 57(9):OCT600-10. PubMed ID: 27627188
[TBL] [Abstract][Full Text] [Related]
5. Accuracy of Swept-Source Optical Coherence Tomography and Ultrasound Biomicroscopy for Evaluation of Posterior Lens Capsule in Traumatic Cataract.
Tabatabaei SA; Soleimani M; Etesali H; Naderan M
Am J Ophthalmol; 2020 Aug; 216():55-58. PubMed ID: 32247777
[TBL] [Abstract][Full Text] [Related]
6. Correlation Between Lens Density Measured by Swept-Source Optical Coherence Tomography and Phacodynamic Parameters of Centurion Phacoemulsification.
Wu X; Chen L; Li Z; Zhao YE
Curr Eye Res; 2023 Jul; 48(7):651-659. PubMed ID: 37009774
[TBL] [Abstract][Full Text] [Related]
7. Volumetric macro- and micro-scale assessment of crystalline lens opacities in cataract patients using long-depth-range swept source optical coherence tomography.
Grulkowski I; Manzanera S; Cwiklinski L; Mompeán J; de Castro A; Marin JM; Artal P
Biomed Opt Express; 2018 Aug; 9(8):3821-3833. PubMed ID: 30338158
[TBL] [Abstract][Full Text] [Related]
8. Average lens density quantification with swept-source optical coherence tomography: optimized, automated cataract grading technique.
Panthier C; de Wazieres A; Rouger H; Moran S; Saad A; Gatinel D
J Cataract Refract Surg; 2019 Dec; 45(12):1746-1752. PubMed ID: 31856985
[TBL] [Abstract][Full Text] [Related]
9. In-vivo anterior segment OCT imaging provides unique insight into cerulean blue-dot opacities and cataracts in Down syndrome.
Little JA; Mahil AS; Richardson P; Woodhouse JM; Vinuela-Navarro V; Saunders KJ
Sci Rep; 2020 Jun; 10(1):10031. PubMed ID: 32572106
[TBL] [Abstract][Full Text] [Related]
10. Effect of Cataract Grade according to Wide-Field Fundus Images on Measurement of Macular Thickness in Cataract Patients.
Kim M; Eom Y; Song JS; Kim HM
Korean J Ophthalmol; 2018 Jun; 32(3):172-181. PubMed ID: 29770639
[TBL] [Abstract][Full Text] [Related]
11. Relationship between Crystalline Lens Thickness and Shape and the Identification of Anterior Ocular Segment Parameters for Predicting the Intraocular Lens Position after Cataract Surgery.
Satou T; Shimizu K; Tsunehiro S; Igarashi A; Kato S; Koshimizu M; Niida T
Biomed Res Int; 2019; 2019():3458548. PubMed ID: 31360711
[TBL] [Abstract][Full Text] [Related]
12. Spectral domain - Optical coherence tomography (SD-OCT) as a monitoring tool for alterations in mouse lenses.
Pawliczek D; Dalke C; Fuchs H; Gailus-Durner V; Hrabě de Angelis M; Graw J; Amarie OV
Exp Eye Res; 2020 Jan; 190():107871. PubMed ID: 31751552
[TBL] [Abstract][Full Text] [Related]
13. Vaulting of myopic and toric Implantable Collamer Lenses during accommodation measured with Visante optical coherence tomography.
Lindland A; Heger H; Kugelberg M; Zetterström C
Ophthalmology; 2010 Jun; 117(6):1245-50. PubMed ID: 20163862
[TBL] [Abstract][Full Text] [Related]
14. Comparison of anterior segment and lens biometric measurements in patients with cataract.
Fukuda S; Ueno Y; Fujita A; Mori H; Tasaki K; Murakami T; Beheregaray S; Oshika T
Graefes Arch Clin Exp Ophthalmol; 2020 Jan; 258(1):137-146. PubMed ID: 31631237
[TBL] [Abstract][Full Text] [Related]
15. Traumatic cataract and other adverse events with the implantable contact lens.
Sarikkola AU; Sen HN; Uusitalo RJ; Laatikainen L
J Cataract Refract Surg; 2005 Mar; 31(3):511-24. PubMed ID: 15811739
[TBL] [Abstract][Full Text] [Related]
16. A Novel Congenital Cataract Category System Based on Lens Opacity Locations and Relevant Anterior Segment Characteristics.
Lin H; Lin D; Liu Z; Long E; Wu X; Cao Q; Chen J; Lin Z; Li X; Zhang L; Chen H; Zhang X; Li J; Chen W; Liu Y
Invest Ophthalmol Vis Sci; 2016 Nov; 57(14):6389-6395. PubMed ID: 27898985
[TBL] [Abstract][Full Text] [Related]
17. Optical coherence tomography assessment of angle anatomy changes after cataract surgery.
Memarzadeh F; Tang M; Li Y; Chopra V; Francis BA; Huang D
Am J Ophthalmol; 2007 Sep; 144(3):464-5. PubMed ID: 17765435
[TBL] [Abstract][Full Text] [Related]
18. Three-Dimensional Reconstruction and Swept-Source Optical Coherence Tomography for Crystalline Lens Tilt and Decentration Relative to the Corneal Vertex.
Dong J; Wang XL; Deng M; Wang XG
Transl Vis Sci Technol; 2021 Aug; 10(9):13. PubMed ID: 34388238
[TBL] [Abstract][Full Text] [Related]
19. Efficacy of Swept-source Optical Coherence Tomography in Axial Length Measurement for Advanced Cataract Patients.
Chirapapaisan C; Srivannaboon S; Chonpimai P
Optom Vis Sci; 2020 Mar; 97(3):186-191. PubMed ID: 32168241
[TBL] [Abstract][Full Text] [Related]
20. Comparison of lens thickness measurements using the anterior segment optical coherence tomography and A-scan ultrasonography.
Zeng Y; Liu Y; Liu X; Chen C; Xia Y; Lu M; He M
Invest Ophthalmol Vis Sci; 2009 Jan; 50(1):290-4. PubMed ID: 18775858
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]