611 related articles for article (PubMed ID: 29437281)
1. Free-breathing dynamic contrast-enhanced MRI for assessment of pulmonary lesions using golden-angle radial sparse parallel imaging.
Chen L; Liu D; Zhang J; Xie B; Zhou X; Grimm R; Huang X; Wang J; Feng L
J Magn Reson Imaging; 2018 Aug; 48(2):459-468. PubMed ID: 29437281
[TBL] [Abstract][Full Text] [Related]
2. Improving dynamic contrast-enhanced MRI of the lung using motion-weighted sparse reconstruction: Initial experiences in patients.
Chen L; Zeng X; Ji B; Liu D; Wang J; Zhang J; Feng L
Magn Reson Imaging; 2020 May; 68():36-44. PubMed ID: 32001328
[TBL] [Abstract][Full Text] [Related]
3. High-resolution free-breathing hepatobiliary phase MRI of the liver using XD-GRASP.
Chen L; Xu J; Liu D; Ji B; Wang J; Zeng X; Zhang J; Feng L
Magn Reson Imaging; 2024 Jun; 109():42-48. PubMed ID: 38447629
[TBL] [Abstract][Full Text] [Related]
4. Free-breathing contrast-enhanced multiphase MRI of the liver using a combination of compressed sensing, parallel imaging, and golden-angle radial sampling.
Chandarana H; Feng L; Block TK; Rosenkrantz AB; Lim RP; Babb JS; Sodickson DK; Otazo R
Invest Radiol; 2013 Jan; 48(1):10-6. PubMed ID: 23192165
[TBL] [Abstract][Full Text] [Related]
5. Free-breathing radial 3D fat-suppressed T1-weighted gradient echo sequence: a viable alternative for contrast-enhanced liver imaging in patients unable to suspend respiration.
Chandarana H; Block TK; Rosenkrantz AB; Lim RP; Kim D; Mossa DJ; Babb JS; Kiefer B; Lee VS
Invest Radiol; 2011 Oct; 46(10):648-53. PubMed ID: 21577119
[TBL] [Abstract][Full Text] [Related]
6. Image Quality of High-Resolution 3-Dimensional Neck MRI Using CAIPIRINHA-VIBE and GRASP-VIBE: An Intraindividual Comparative Study.
Seo M; Yoon J; Choi Y; Nickel D; Jang J; Shin NY; Ahn KJ; Kim BS
Invest Radiol; 2022 Nov; 57(11):711-719. PubMed ID: 35703461
[TBL] [Abstract][Full Text] [Related]
7. Respiratory motion compensation using data binning in dynamic contrast enhanced golden-angle radial MRI.
Shahzadi I; Siddiqui MF; Aslam I; Omer H
Magn Reson Imaging; 2020 Jul; 70():115-125. PubMed ID: 32360531
[TBL] [Abstract][Full Text] [Related]
8. GRASP-Pro: imProving GRASP DCE-MRI through self-calibrating subspace-modeling and contrast phase automation.
Feng L; Wen Q; Huang C; Tong A; Liu F; Chandarana H
Magn Reson Med; 2020 Jan; 83(1):94-108. PubMed ID: 31400028
[TBL] [Abstract][Full Text] [Related]
9. Comparison of image quality of subtracted and nonsubtracted breath hold VIBE and free breathing GRASP in the evaluation of renal masses.
Huber S; Balcacer De la Cruz P; Mahan M; Spektor M; Lo R; Block KT; Israel G
Clin Imaging; 2021 Jun; 74():15-18. PubMed ID: 33421698
[TBL] [Abstract][Full Text] [Related]
10. Intraindividual Comparison of Compressed Sensing-Accelerated Cartesian and Radial Arterial Phase Imaging of the Liver in an Experimental Tumor Model.
Harder FN; Budjan J; Nickel MD; Grimm R; Pietsch H; Schoenberg SO; Jost G; Attenberger UI
Invest Radiol; 2021 Jul; 56(7):433-441. PubMed ID: 33813577
[TBL] [Abstract][Full Text] [Related]
11. Free-breathing contrast-enhanced multiphase MRI of the liver in patients with a high risk of breath-holding failure: comparison of compressed sensing-accelerated radial and Cartesian acquisition techniques.
Choi ES; Kim JS; Nickel MD; Sung JK; Lee JK
Acta Radiol; 2022 Nov; 63(11):1453-1462. PubMed ID: 34839679
[TBL] [Abstract][Full Text] [Related]
12. Free-breathing radial stack-of-stars three-dimensional Dixon gradient echo sequence in abdominal magnetic resonance imaging in sedated pediatric patients.
Duffy PB; Stemmer A; Callahan MJ; Cravero JP; Johnston PR; Warfield SK; Bixby SD
Pediatr Radiol; 2021 Aug; 51(9):1645-1653. PubMed ID: 33830291
[TBL] [Abstract][Full Text] [Related]
13. Achieving high spatial and temporal resolution with perfusion MRI in the head and neck region using golden-angle radial sampling.
Tomppert A; Wuest W; Wiesmueller M; Heiss R; Kopp M; Nagel AM; Tomita H; Meixner C; Uder M; May MS
Eur Radiol; 2021 Apr; 31(4):2263-2271. PubMed ID: 32970184
[TBL] [Abstract][Full Text] [Related]
14. Image quality optimization: dynamic contrast-enhanced MRI of the abdomen at 3T using a continuously acquired radial golden-angle compressed sensing acquisition.
Pan J; Shao X; Liu H; Li Y; Wang Q
Abdom Radiol (NY); 2024 Feb; 49(2):399-405. PubMed ID: 37792056
[TBL] [Abstract][Full Text] [Related]
15. 4D Golden-Angle Radial MRI at Subsecond Temporal Resolution.
Feng L
NMR Biomed; 2023 Feb; 36(2):e4844. PubMed ID: 36259951
[TBL] [Abstract][Full Text] [Related]
16. Dynamic contrast-enhanced MRI parametric mapping using high spatiotemporal resolution Golden-angle RAdial Sparse Parallel MRI and iterative joint estimation of the arterial input function and pharmacokinetic parameters.
Mazaheri Y; Kim N; Lakhman Y; Jafari R; Vargas A; Otazo R
NMR Biomed; 2022 Jul; 35(7):e4718. PubMed ID: 35226774
[TBL] [Abstract][Full Text] [Related]
17. Free-breathing dynamic contrast-enhanced MRI of the abdomen and chest using a radial gradient echo sequence with K-space weighted image contrast (KWIC).
Kim KW; Lee JM; Jeon YS; Kang SE; Baek JH; Han JK; Choi BI; Bang YJ; Kiefer B; Block KT; Ji H; Bauer S; Kim C
Eur Radiol; 2013 May; 23(5):1352-60. PubMed ID: 23187728
[TBL] [Abstract][Full Text] [Related]
18. Dynamic contrast-enhanced MRI of the prostate with high spatiotemporal resolution using compressed sensing, parallel imaging, and continuous golden-angle radial sampling: preliminary experience.
Rosenkrantz AB; Geppert C; Grimm R; Block TK; Glielmi C; Feng L; Otazo R; Ream JM; Romolo MM; Taneja SS; Sodickson DK; Chandarana H
J Magn Reson Imaging; 2015 May; 41(5):1365-73. PubMed ID: 24833417
[TBL] [Abstract][Full Text] [Related]
19. Dynamic contrast-enhanced MR imaging of rectal cancer using a golden-angle radial stack-of-stars VIBE sequence: comparison with conventional contrast-enhanced 3D VIBE sequence.
Li Y; Xia C; Peng W; Gao Y; Hu S; Zhang K; Zhao F; Benkert T; Zhou X; Zhang H; Li Z
Abdom Radiol (NY); 2020 Feb; 45(2):322-331. PubMed ID: 31552465
[TBL] [Abstract][Full Text] [Related]
20. Impact of temporal resolution and motion correction for dynamic contrast-enhanced MRI of the liver using an accelerated golden-angle radial sequence.
Mansour R; Thibodeau Antonacci A; Bilodeau L; Vazquez Romaguera L; Cerny M; Huet C; Gilbert G; Tang A; Kadoury S
Phys Med Biol; 2020 Apr; 65(8):085004. PubMed ID: 32084661
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]