These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

86 related articles for article (PubMed ID: 2943946)

  • 1. Hydrogen bubble visualization of the flow past aortic prosthetic valves.
    Lichtenstein O; Martínez-Val R; Méndez J; Castillo-Olivares JL
    Life Support Syst; 1986; 4(2):141-9. PubMed ID: 2943946
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vitro pulsatile flow measurements in the vicinity of mechanical heart valves in the mitral flow chamber.
    Woo YR; Yoganathan AP
    Life Support Syst; 1986; 4(2):115-39. PubMed ID: 2943945
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro velocity and turbulence measurements in the vicinity of three new mechanical aortic heart valve prostheses: Björk-Shiley Monostrut, Omni-Carbon, and Duromedics.
    Yoganathan AP; Sung HW; Woo YR; Jones M
    J Thorac Cardiovasc Surg; 1988 May; 95(5):929-39. PubMed ID: 3361941
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vitro pulsatile flow velocity and turbulent shear stress measurements in the vicinity of mechanical aortic heart valve prostheses.
    Woo YR; Yoganathan AP
    Life Support Syst; 1985; 3(4):283-312. PubMed ID: 4068753
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An instrument for the measurement of in vitro velocity and turbulent shear stress in the immediate vicinity of prosthetic heart valves.
    Woo YR; Yoganathan AP
    Life Support Syst; 1986; 4(1):47-62. PubMed ID: 2937981
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Instantaneous blood flow velocity profiles before and after aortic valve replacement (author's transl)].
    Meisner H; Hagl S; Heimisch W; Gams E; Erben R; Struck E; Schmidt-Habelmann P; Sebening F
    Thoraxchir Vask Chir; 1975 Jun; 23(3):282-90. PubMed ID: 1080605
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Bubble formation on St. Jude Medical mechanical heart valves: an in-vitro study.
    Milo S; Gutfinger C; Chu GY; Gharib M
    J Heart Valve Dis; 2003 May; 12(3):406-10. PubMed ID: 12803343
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In vitro evaluation of the long-body On-X bileaflet heart valve.
    Hwang NH; Reul H; Reinhard P
    J Heart Valve Dis; 1998 Sep; 7(5):561-8. PubMed ID: 9793857
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of valve orientation on flow development past aortic valve prostheses in a model human aorta.
    Chandran KB; Khalighi B; Chen CJ; Falsetti HL; Yearwood TL; Hiratzka LF
    J Thorac Cardiovasc Surg; 1983 Jun; 85(6):893-901. PubMed ID: 6855259
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Principal stress analysis in LDA measurement of the flow field downstream of 19-mm Sorin Bicarbon heart valve.
    Barbaro V; Grigioni M; Daniele C; D'Avenio G
    Technol Health Care; 1998 Nov; 6(4):259-70. PubMed ID: 9924953
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An in vitro investigation of the retrograde flow fields of two bileaflet mechanical heart valves.
    Ellis JT; Healy TM; Fontaine AA; Weston MW; Jarret CA; Saxena R; Yoganathan AP
    J Heart Valve Dis; 1996 Nov; 5(6):600-6. PubMed ID: 8953437
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Noninvasive determination of the orifice area of aortic valve prostheses using Doppler echocardiography].
    Dennig K; Rudolph W
    Herz; 1986 Dec; 11(6):341-5. PubMed ID: 3817727
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Two-component laser Doppler anemometer for measurement of velocity and turbulent shear stress near prosthetic heart valves.
    Woo YR; Yoganathan AP
    Med Instrum; 1985; 19(5):224-31. PubMed ID: 2932625
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In vitro heart valve testing: steady versus pulsatile flow.
    Black MM; Hose DR; Lamb CJ; Lawford PV; Ralph SJ
    J Heart Valve Dis; 1994 Mar; 3(2):212-5. PubMed ID: 8012641
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High-resolution assessment of velocity fields and shear stresses distal to prosthetic heart valves using high-field magnetic resonance imaging.
    Ringgaard S; Botnar RM; Djurhuus C; Stodkilde-Jorgensen H; Hasenkam JM; Boesiger P; Pedersen EM
    J Heart Valve Dis; 1999 Jan; 8(1):96-103. PubMed ID: 10096490
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An integrated macro/micro approach to evaluating pivot flow within the Medtronic ADVANTAGE bileaflet mechanical heart valve.
    Shu MC; Gross JM; O'Rourke KK; Yoganathan AP
    J Heart Valve Dis; 2003 Jul; 12(4):503-12. PubMed ID: 12918854
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Medtronic Hall versus St. Jude Medical mechanical aortic valve: downstream turbulences with respect to rotation in pigs.
    Kleine P; Perthel M; Nygaard H; Hansen SB; Paulsen PK; Riis C; Laas J
    J Heart Valve Dis; 1998 Sep; 7(5):548-55. PubMed ID: 9793855
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In-vitro wall shear measurements at aortic valve prostheses.
    Tillmann W; Reul H; Herold M; Bruss KH; van Gilse J
    J Biomech; 1984; 17(4):263-79. PubMed ID: 6736063
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In-vitro hemodynamics of stented bioprosthetic heart valves in the tilted implantation position.
    Babin-Ebell J; Sievers HH; Misfeld M; Runge M; Vogt PR; Scharfschwerdt M
    J Heart Valve Dis; 2008 Sep; 17(5):566-70. PubMed ID: 18980091
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Usefulness of magnetic resonance imaging for managing patients with prosthetic carbon valve in the mitral position].
    Koito H; Imai Y; Suzuki J; Ohkubo N; Nakamura C; Takahashi H; Iwasaka T; Inada M
    J Cardiol; 1997 Nov; 30(5):251-63. PubMed ID: 9395956
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.