These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

178 related articles for article (PubMed ID: 29443350)

  • 1. Coronary stent restenosis and the association with allergy to metal content of 316L stainless steel.
    Slodownik D; Danenberg C; Merkin D; Swaid F; Moshe S; Ingber A; Lotan H; Durst R
    Cardiovasc J Afr; 2018 Jan/Feb 23; 29(1):43-45. PubMed ID: 29443350
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis.
    Köster R; Vieluf D; Kiehn M; Sommerauer M; Kähler J; Baldus S; Meinertz T; Hamm CW
    Lancet; 2000 Dec; 356(9245):1895-7. PubMed ID: 11130387
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Metal allergic reaction in chronic refractory in-stent restenosis.
    Saito T; Hokimoto S; Oshima S; Noda K; Kojyo Y; Matsunaga K
    Cardiovasc Revasc Med; 2009; 10(1):17-22. PubMed ID: 19159850
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Is there a link between nickel allergy and coronary stent restenosis?
    Norgaz T; Hobikoglu G; Serdar ZA; Aksu H; Alper AT; Ozer O; Narin A
    Tohoku J Exp Med; 2005 Jul; 206(3):243-6. PubMed ID: 15942152
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Does nickel allergy play a role in the development of in-stent restenosis?
    El-Mawardy R; Fuad H; Abdel-Salam Z; Ghazy M; Nammas W
    Eur Rev Med Pharmacol Sci; 2011 Nov; 15(11):1235-40. PubMed ID: 22195354
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Metal allergy to everolimus-eluting cobalt chromium stents confirmed by positive skin testing as a cause of recurrent multivessel in-stent restenosis.
    Nakajima Y; Itoh T; Morino Y
    Catheter Cardiovasc Interv; 2016 Mar; 87(4):E137-42. PubMed ID: 26011018
    [TBL] [Abstract][Full Text] [Related]  

  • 7. In-stent restenosis because of nickel hypersensitivity: a bioresorbable solution?
    Granata F; Moscarella E; Varricchio A
    Coron Artery Dis; 2015 Aug; 26(5):461-2. PubMed ID: 25816019
    [No Abstract]   [Full Text] [Related]  

  • 8. A correlation found between contact allergy to stent material and restenosis of the coronary arteries.
    Svedman C; Ekqvist S; Möller H; Björk J; Pripp CM; Gruvberger B; Holmström E; Gustavsson CG; Bruze M
    Contact Dermatitis; 2009 Mar; 60(3):158-64. PubMed ID: 19260914
    [TBL] [Abstract][Full Text] [Related]  

  • 9. High frequency of contact allergy to gold in patients with endovascular coronary stents.
    Ekqvist S; Svedman C; Möller H; Kehler M; Pripp CM; Björk J; Gruvberger B; Holmström E; Gustavsson CG; Bruze M
    Br J Dermatol; 2007 Oct; 157(4):730-8. PubMed ID: 17711524
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of metal allergies in patients with coronary stents.
    Hillen U; Haude M; Erbel R; Goos M
    Contact Dermatitis; 2002 Dec; 47(6):353-6. PubMed ID: 12581282
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison between catheter-based delivery of paclitaxel after bare-metal stenting and drug-eluting stents in coronary artery disease patients at high risk for in-stent restenosis.
    El-Mokadem M; El-Ramly M; Hassan A; Boshra H; AbdelWahab A
    Cardiovasc Revasc Med; 2017 Dec; 18(8):596-600. PubMed ID: 28625402
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The impact of metallic allergy on stent implantation: metal allergy and recurrence of in-stent restenosis.
    Iijima R; Ikari Y; Amiya E; Tanimoto S; Nakazawa G; Kyono H; Hatori M; Miyazawa A; Nakayama T; Aoki J; Nakajima H; Hara K
    Int J Cardiol; 2005 Oct; 104(3):319-25. PubMed ID: 16186063
    [TBL] [Abstract][Full Text] [Related]  

  • 13. No association between metal allergy and cardiac in-stent restenosis in patients with dermatitis-results from a linkage study.
    Thyssen JP; Engkilde K; Menné T; Johansen JD; Hansen PR; Gislason GH
    Contact Dermatitis; 2011 Mar; 64(3):138-41. PubMed ID: 21226719
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect on Clinical Restenosis of an Ultra-Thin-Strut Bare Metal Cobalt-Chromium Stent Versus a Thin-Strut Stainless Steel Stent.
    Silenzi S; Grossi P; Mariani L; Fraccaro C; Vagnarelli F; Moretti L
    J Interv Cardiol; 2016 Jun; 29(3):300-10. PubMed ID: 27242170
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Coronary in-stent restenosis: predisposing clinical and stent-related factors, diagnostic performance and analyses of inaccuracies in 320-row computed tomography angiography.
    Wan YL; Tsay PK; Chen CC; Juan YH; Huang YC; Chan WH; Wen MS; Hsieh IC
    Int J Cardiovasc Imaging; 2016 Jun; 32 Suppl 1():105-15. PubMed ID: 27106698
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical and angiographic results of percutaneous coronary revascularization using a trilayer stainless steel-tantalum-stainless steel phosphorylcholine-coated stent: the TriMaxx trial.
    Abizaid A; Popma JJ; Tanajura LF; Hattori K; Solberg B; Larracas C; Feres F; Costa Jde R; Schwartz LB
    Catheter Cardiovasc Interv; 2007 Dec; 70(7):914-9. PubMed ID: 18044791
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Everolimus-Eluting Stents in Patients With Bare-Metal and Drug-Eluting In-Stent Restenosis: Results From a Patient-Level Pooled Analysis of the RIBS IV and V Trials.
    Alfonso F; Pérez-Vizcayno MJ; García Del Blanco B; García-Touchard A; López-Mínguez JR; Masotti M; Zueco J; Melgares R; Mainar V; Moreno R; Domínguez A; Sanchís J; Bethencourt A; Moreu J; Cequier A; Martí V; Otaegui I; Bastante T; Gonzalo N; Jiménez-Quevedo P; Cárdenas A; Fernández C;
    Circ Cardiovasc Interv; 2016 Jul; 9(7):. PubMed ID: 27412868
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Stent implantation in patients with metal allergy: a systemic review and meta-analysis.
    Gong Z; Li M; Guo X; Ma Z; Shi J
    Coron Artery Dis; 2013 Dec; 24(8):684-9. PubMed ID: 24135817
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Systemic hypersensitivity reaction to endovascular stainless steel stent.
    Univers J; Long C; Tonks SA; Freeman MB
    J Vasc Surg; 2018 Feb; 67(2):615-617. PubMed ID: 29248243
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Impact of stent diameter and length on in-stent restenosis after DES vs BMS implantation in patients needing large coronary stents-A clinical and health-economic evaluation.
    Zbinden R; von Felten S; Wein B; Tueller D; Kurz DJ; Reho I; Galatius S; Alber H; Conen D; Pfisterer M; Kaiser C; Eberli FR
    Cardiovasc Ther; 2017 Feb; 35(1):19-25. PubMed ID: 27662632
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.