These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
467 related articles for article (PubMed ID: 29444961)
1. No inferiority of Tonbridge thrombectomy device for acute thrombus retrial compared with Solitaire device: an experimental evaluation with a canine distal external carotid-maxillary artery occlusion model. Zhou G; Li MH; Lu HT; Deng JS; Zhao YW; Wang YXJ; Zhu YQ J Neurointerv Surg; 2018 Nov; 10(11):1085-1091. PubMed ID: 29444961 [TBL] [Abstract][Full Text] [Related]
2. Thrombus density predicts successful recanalization with Solitaire stent retriever thrombectomy in acute ischemic stroke. Mokin M; Morr S; Natarajan SK; Lin N; Snyder KV; Hopkins LN; Siddiqui AH; Levy EI J Neurointerv Surg; 2015 Feb; 7(2):104-7. PubMed ID: 24510378 [TBL] [Abstract][Full Text] [Related]
3. Efficacy and Safety of a Novel Thrombectomy Device in Patients With Acute Ischemic Stroke: A Randomized Controlled Trial. Zhang Y; Hua W; Li Z; Peng Y; Han Z; Li T; Yin C; Wang S; Nan G; Zhao Z; Yang H; Zhou B; Li T; Cai Y; Zhang J; Li G; Peng X; Guan S; Zhou J; Ye M; Wang L; Zhang L; Hong B; Zhang Y; Wan J; Wang Y; Zhu Q; Liu J; Yang P Front Neurol; 2021; 12():686253. PubMed ID: 34456847 [No Abstract] [Full Text] [Related]
4. Patterns and Clinical Impact of Angiographically Visible Distal Emboli During Thrombectomy With Solitaire for Acute Ischemic Stroke. Mazur MD; Kilburg C; Park MS; Taussky P Neurosurgery; 2016 Feb; 78(2):242-50. PubMed ID: 26600280 [TBL] [Abstract][Full Text] [Related]
5. SOLITAIRE™ with the intention for thrombectomy (SWIFT) trial: design of a randomized, controlled, multicenter study comparing the SOLITAIRE™ Flow Restoration device and the MERCI Retriever in acute ischaemic stroke. Saver JL; Jahan R; Levy EI; Jovin TG; Baxter B; Nogueira R; Clark W; Budzik R; Zaidat OO; Int J Stroke; 2014 Jul; 9(5):658-68. PubMed ID: 23130938 [TBL] [Abstract][Full Text] [Related]
6. Endovascular treatment of acute intracerebral artery occlusions with the solitaire stent: single-centre experience with 108 recanalization procedures. Dorn F; Stehle S; Lockau H; Zimmer C; Liebig T Cerebrovasc Dis; 2012; 34(1):70-7. PubMed ID: 22759754 [TBL] [Abstract][Full Text] [Related]
7. Mechanical thrombectomy injury to the arterial wall: A comparison between catheter aspiration and stent retriever. He G; Deng J; Zhang Y; Lu H; Zhao Y; Yan L; Zhu Y Eur J Radiol; 2021 Jun; 139():109723. PubMed ID: 33905977 [TBL] [Abstract][Full Text] [Related]
8. Mechanical thrombectomy using a Solitaire stent retriever in the treatment of pediatric acute ischemic stroke. Zhou B; Wang XC; Xiang JY; Zhang MZ; Li B; Jiang HB; Lu XD J Neurosurg Pediatr; 2019 Mar; 23(3):363-368. PubMed ID: 30611154 [TBL] [Abstract][Full Text] [Related]
9. Mechanical thrombectomy by Solitaire stent for treating acute ischemic stroke: A prospective cohort study. Jiang SW; Wang HR; Peng Y; Sun H; Chen M; Fei AH; Pan SM Int J Surg; 2016 Apr; 28():2-7. PubMed ID: 26892715 [TBL] [Abstract][Full Text] [Related]
11. Primary Results of the Multicenter ARISE II Study (Analysis of Revascularization in Ischemic Stroke With EmboTrap). Zaidat OO; Bozorgchami H; Ribó M; Saver JL; Mattle HP; Chapot R; Narata AP; Francois O; Jadhav AP; Grossberg JA; Riedel CH; Tomasello A; Clark WM; Nordmeyer H; Lin E; Nogueira RG; Yoo AJ; Jovin TG; Siddiqui AH; Bernard T; Claffey M; Andersson T Stroke; 2018 May; 49(5):1107-1115. PubMed ID: 29643261 [TBL] [Abstract][Full Text] [Related]
12. Mechanical thrombectomy with the Solitaire AB stent for treatment of acute basilar artery occlusion: A single-center experience. Du S; Mao G; Li D; Qiu M; Nie Q; Zhu H; Yang Y; Zhang Y; Li Y; Wu Z J Clin Neurosci; 2016 Oct; 32():67-71. PubMed ID: 27312281 [TBL] [Abstract][Full Text] [Related]
13. Early experience with stent retrievers and comparison with previous-generation mechanical thrombectomy devices for acute ischemic stroke. Deshaies EM; Singla A; Villwock MR; Padalino DJ; Sharma S; Swarnkar A J Neurosurg; 2014 Jul; 121(1):12-7. PubMed ID: 24605837 [TBL] [Abstract][Full Text] [Related]
14. Comparison of Solitaire thrombectomy and Penumbra suction thrombectomy in patients with acute ischemic stroke caused by basilar artery occlusion. Son S; Choi DS; Oh MK; Hong J; Kim SK; Kang H; Park KJ; Choi NC; Kwon OY; Lim BH J Neurointerv Surg; 2016 Jan; 8(1):13-8. PubMed ID: 25411420 [TBL] [Abstract][Full Text] [Related]
15. Management of acute ischemic stroke due to tandem occlusion: should endovascular recanalization of the extracranial or intracranial occlusive lesion be done first? Rangel-Castilla L; Rajah GB; Shakir HJ; Shallwani H; Gandhi S; Davies JM; Snyder KV; Levy EI; Siddiqui AH Neurosurg Focus; 2017 Apr; 42(4):E16. PubMed ID: 28366065 [TBL] [Abstract][Full Text] [Related]
16. A comparison of 2 stroke devices: the new Aperio clot-removal device and the solitaire AB/FR. Roth C; Junk D; Papanagiotou P; Keuler A; Körner H; Schumacher M; Reith W AJNR Am J Neuroradiol; 2012 Aug; 33(7):1317-20. PubMed ID: 22300938 [TBL] [Abstract][Full Text] [Related]
17. Solitaire flow restoration device versus the Merci Retriever in patients with acute ischaemic stroke (SWIFT): a randomised, parallel-group, non-inferiority trial. Saver JL; Jahan R; Levy EI; Jovin TG; Baxter B; Nogueira RG; Clark W; Budzik R; Zaidat OO; Lancet; 2012 Oct; 380(9849):1241-9. PubMed ID: 22932715 [TBL] [Abstract][Full Text] [Related]
18. Association of clot burden score with radiographic and clinical outcomes following Solitaire stent retriever thrombectomy: analysis of the SWIFT PRIME trial. Mokin M; Levy EI; Siddiqui AH; Goyal M; Nogueira RG; Yavagal DR; M Pereira V; Saver JL J Neurointerv Surg; 2017 Oct; 9(10):929-932. PubMed ID: 27634952 [TBL] [Abstract][Full Text] [Related]
19. Solitaire FR revascularization device 4×40: safety study and effectiveness in preclinical models. Wainwright JM; Jahan R J Neurointerv Surg; 2016 Jul; 8(7):710-3. PubMed ID: 26101268 [TBL] [Abstract][Full Text] [Related]