These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

491 related articles for article (PubMed ID: 29454767)

  • 1. Diagnostic Performance of Fully Automated Pixel-Wise Quantitative Myocardial Perfusion Imaging by Cardiovascular Magnetic Resonance.
    Hsu LY; Jacobs M; Benovoy M; Ta AD; Conn HM; Winkler S; Greve AM; Chen MY; Shanbhag SM; Bandettini WP; Arai AE
    JACC Cardiovasc Imaging; 2018 May; 11(5):697-707. PubMed ID: 29454767
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fully automated pixel-wise quantitative CMR-myocardial perfusion with CMR-coronary angiography to detect hemodynamically significant coronary artery disease.
    Zhao SH; Guo WF; Yao ZF; Yang S; Yun H; Chen YY; Han TT; Zhou XY; Fu CX; Zeng MS; Li CG; Pan CZ; Jin H
    Eur Radiol; 2023 Oct; 33(10):7238-7249. PubMed ID: 37145148
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Automated Pixel-Wise Quantitative Myocardial Perfusion Mapping by CMR to Detect Obstructive Coronary Artery Disease and Coronary Microvascular Dysfunction: Validation Against Invasive Coronary Physiology.
    Kotecha T; Martinez-Naharro A; Boldrini M; Knight D; Hawkins P; Kalra S; Patel D; Coghlan G; Moon J; Plein S; Lockie T; Rakhit R; Patel N; Xue H; Kellman P; Fontana M
    JACC Cardiovasc Imaging; 2019 Oct; 12(10):1958-1969. PubMed ID: 30772231
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fully quantitative pixel-wise analysis of cardiovascular magnetic resonance perfusion improves discrimination of dark rim artifact from perfusion defects associated with epicardial coronary stenosis.
    Ta AD; Hsu LY; Conn HM; Winkler S; Greve AM; Shanbhag SM; Chen MY; Patricia Bandettini W; Arai AE
    J Cardiovasc Magn Reson; 2018 Mar; 20(1):16. PubMed ID: 29514708
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantitative three-dimensional cardiovascular magnetic resonance myocardial perfusion imaging in systole and diastole.
    Motwani M; Kidambi A; Sourbron S; Fairbairn TA; Uddin A; Kozerke S; Greenwood JP; Plein S
    J Cardiovasc Magn Reson; 2014 Feb; 16(1):19. PubMed ID: 24565078
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Diagnostic value of global myocardial perfusion reserve assessment based on coronary sinus flow measurements using cardiovascular magnetic resonance in addition to myocardial stress perfusion imaging.
    Shomanova Z; Florian A; Bietenbeck M; Waltenberger J; Sechtem U; Yilmaz A
    Eur Heart J Cardiovasc Imaging; 2017 May; 18(8):851-859. PubMed ID: 28369259
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A comparison of cardiovascular magnetic resonance and single photon emission computed tomography (SPECT) perfusion imaging in left main stem or equivalent coronary artery disease: a CE-MARC substudy.
    Foley JRJ; Kidambi A; Biglands JD; Maredia N; Dickinson CJ; Plein S; Greenwood JP
    J Cardiovasc Magn Reson; 2017 Nov; 19(1):84. PubMed ID: 29110669
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fully automated, inline quantification of myocardial blood flow with cardiovascular magnetic resonance: repeatability of measurements in healthy subjects.
    Brown LAE; Onciul SC; Broadbent DA; Johnson K; Fent GJ; Foley JRJ; Garg P; Chew PG; Knott K; Dall'Armellina E; Swoboda PP; Xue H; Greenwood JP; Moon JC; Kellman P; Plein S
    J Cardiovasc Magn Reson; 2018 Jul; 20(1):48. PubMed ID: 29983119
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A quantitative pixel-wise measurement of myocardial blood flow by contrast-enhanced first-pass CMR perfusion imaging: microsphere validation in dogs and feasibility study in humans.
    Hsu LY; Groves DW; Aletras AH; Kellman P; Arai AE
    JACC Cardiovasc Imaging; 2012 Feb; 5(2):154-66. PubMed ID: 22340821
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Underestimation of myocardial blood flow by dynamic perfusion CT: Explanations by two-compartment model analysis and limited temporal sampling of dynamic CT.
    Ishida M; Kitagawa K; Ichihara T; Natsume T; Nakayama R; Nagasawa N; Kubooka M; Ito T; Uno M; Goto Y; Nagata M; Sakuma H
    J Cardiovasc Comput Tomogr; 2016; 10(3):207-14. PubMed ID: 26851149
    [TBL] [Abstract][Full Text] [Related]  

  • 11. High-resolution free-breathing automated quantitative myocardial perfusion by cardiovascular magnetic resonance for the detection of functionally significant coronary artery disease.
    Crawley R; Kunze KP; Milidonis X; Highton J; McElroy S; Frey SM; Hoefler D; Karamanli C; Wong NCK; Backhaus SJ; Alskaf E; Neji R; Scannell CM; Plein S; Chiribiri A
    Eur Heart J Cardiovasc Imaging; 2024 Jun; 25(7):914-925. PubMed ID: 38525948
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Quantitative myocardial perfusion in coronary artery disease: A perfusion mapping study.
    Knott KD; Camaioni C; Ramasamy A; Augusto JA; Bhuva AN; Xue H; Manisty C; Hughes RK; Brown LAE; Amersey R; Bourantas C; Kellman P; Plein S; Moon JC
    J Magn Reson Imaging; 2019 Sep; 50(3):756-762. PubMed ID: 30684288
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Influence of the arterial input sampling location on the diagnostic accuracy of cardiovascular magnetic resonance stress myocardial perfusion quantification.
    Milidonis X; Franks R; Schneider T; Sánchez-González J; Sammut EC; Plein S; Chiribiri A
    J Cardiovasc Magn Reson; 2021 Mar; 23(1):35. PubMed ID: 33775247
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Coronary artery stenosis-related perfusion ratio using dynamic computed tomography myocardial perfusion imaging: a pilot for identification of hemodynamically significant coronary artery disease.
    Kuwahara N; Tanabe Y; Kido T; Kurata A; Uetani T; Ochi H; Kawaguchi N; Kido T; Ikeda S; Yamaguchi O; Asano M; Mochizuki T
    Cardiovasc Interv Ther; 2020 Oct; 35(4):327-335. PubMed ID: 31630340
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quantitative assessment of myocardial blood flow in coronary artery disease by cardiovascular magnetic resonance: comparison of Fermi and distributed parameter modeling against invasive methods.
    Papanastasiou G; Williams MC; Dweck MR; Alam S; Cooper A; Mirsadraee S; Newby DE; Semple SI
    J Cardiovasc Magn Reson; 2016 Sep; 18(1):57. PubMed ID: 27624746
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantitative pixel-wise measurement of myocardial blood flow: the impact of surface coil-related field inhomogeneity and a comparison of methods for its correction.
    Miller CA; Hsu LY; Ta A; Conn H; Winkler S; Arai AE
    J Cardiovasc Magn Reson; 2015 Feb; 17(1):11. PubMed ID: 25827156
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Sex- and age-specific normal values for automated quantitative pixel-wise myocardial perfusion cardiovascular magnetic resonance.
    Brown LAE; Gulsin GS; Onciul SC; Broadbent DA; Yeo JL; Wood AL; Saunderson CED; Das A; Jex N; Chowdhary A; Thirunavukarasu S; Sharrack N; Knott KD; Levelt E; Swoboda PP; Xue H; Greenwood JP; Moon JC; Adlam D; McCann GP; Kellman P; Plein S
    Eur Heart J Cardiovasc Imaging; 2023 Mar; 24(4):426-434. PubMed ID: 36458882
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Voxel-wise quantification of myocardial blood flow with cardiovascular magnetic resonance: effect of variations in methodology and validation with positron emission tomography.
    Miller CA; Naish JH; Ainslie MP; Tonge C; Tout D; Arumugam P; Banerji A; Egdell RM; Clark D; Weale P; Steadman CD; McCann GP; Ray SG; Parker GJ; Schmitt M
    J Cardiovasc Magn Reson; 2014 Jan; 16(1):11. PubMed ID: 24460930
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Integrated Myocardial Perfusion Imaging Diagnostics Improve Detection of Functionally Significant Coronary Artery Stenosis by 13N-ammonia Positron Emission Tomography.
    Lee JM; Kim CH; Koo BK; Hwang D; Park J; Zhang J; Tong Y; Jeon KH; Bang JI; Suh M; Paeng JC; Cheon GJ; Na SH; Ahn JM; Park SJ; Kim HS
    Circ Cardiovasc Imaging; 2016 Sep; 9(9):. PubMed ID: 27609817
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Combined Assessment of Stress Myocardial Perfusion Cardiovascular Magnetic Resonance and Flow Measurement in the Coronary Sinus Improves Prediction of Functionally Significant Coronary Stenosis Determined by Fractional Flow Reserve in Multivessel Disease.
    Nakamori S; Sakuma H; Dohi K; Ishida M; Tanigawa T; Yamada A; Takase S; Nakajima H; Sawai T; Masuda J; Nagata M; Ichikawa Y; Kitagawa K; Fujii E; Yamada N; Ito M
    J Am Heart Assoc; 2018 Jan; 7(3):. PubMed ID: 29432130
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 25.