These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 29457342)

  • 1. Soft tissue balancing in total knee arthroplasty using sensor-guided assessment: is there a learning curve?
    Gharaibeh MA; Chen DB; MacDessi SJ
    ANZ J Surg; 2018 May; 88(5):497-501. PubMed ID: 29457342
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Are Patients More Satisfied With a Balanced Total Knee Arthroplasty?
    Golladay GJ; Bradbury TL; Gordon AC; Fernandez-Madrid IJ; Krebs VE; Patel PD; Suarez JC; Higuera Rueda CA; Barsoum WK
    J Arthroplasty; 2019 Jul; 34(7S):S195-S200. PubMed ID: 31079993
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Randomized Controlled Trial of Sensor-Guided Knee Balancing Compared to Standard Balancing Technique in Total Knee Arthroplasty.
    Wood TJ; Winemaker MJ; Williams DS; Petruccelli DT; Tushinski DM; de Beer JV
    J Arthroplasty; 2021 Mar; 36(3):953-957. PubMed ID: 33041172
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Soft tissue balance measurement in minimal incision surgery compared to conventional total knee arthroplasty.
    Matsumoto T; Muratsu H; Kubo S; Mizuno K; Kinoshita K; Ishida K; Matsushita T; Sasaki K; Tei K; Takayama K; Sasaki H; Oka S; Kurosaka M; Kuroda R
    Knee Surg Sports Traumatol Arthrosc; 2011 Jun; 19(6):880-6. PubMed ID: 20680244
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Restoring the constitutional alignment with a restrictive kinematic protocol improves quantitative soft-tissue balance in total knee arthroplasty: a randomized controlled trial.
    MacDessi SJ; Griffiths-Jones W; Chen DB; Griffiths-Jones S; Wood JA; Diwan AD; Harris IA
    Bone Joint J; 2020 Jan; 102-B(1):117-124. PubMed ID: 31888372
    [TBL] [Abstract][Full Text] [Related]  

  • 6. No Benefit to Sensor-guided Balancing Compared With Freehand Balancing in TKA: A Randomized Controlled Trial.
    Sarpong NO; Held MB; Grosso MJ; Herndon CL; Santos W; Lakra A; Shah RP; Cooper HJ; Geller JA
    Clin Orthop Relat Res; 2022 Aug; 480(8):1535-1544. PubMed ID: 35394462
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Objective quantification of ligament balancing using VERASENSE in measured resection and modified gap balance total knee arthroplasty.
    Cho KJ; Seon JK; Jang WY; Park CG; Song EK
    BMC Musculoskelet Disord; 2018 Jul; 19(1):266. PubMed ID: 30053812
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Functional alignment achieves soft-tissue balance in total knee arthroplasty as measured with quantitative sensor-guided technology.
    Chang JS; Kayani B; Wallace C; Haddad FS
    Bone Joint J; 2021 Mar; 103-B(3):507-514. PubMed ID: 33467917
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Kinetic Sensors for Ligament Balance and Kinematic Evaluation in Anatomic Bi-Cruciate Stabilized Total Knee Arthroplasty.
    Sabatini L; Bosco F; Barberis L; Camazzola D; Bistolfi A; Risitano S; Massè A; Indelli PF
    Sensors (Basel); 2021 Aug; 21(16):. PubMed ID: 34450869
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of Intraoperative Soft Tissue Balance Between Cruciate-Retaining and Posterior-Stabilized Total Knee Arthroplasty Performed by a Newly Developed Medial Preserving Gap Technique.
    Tsubosaka M; Muratsu H; Takayama K; Miya H; Kuroda R; Matsumoto T
    J Arthroplasty; 2018 Mar; 33(3):729-734. PubMed ID: 29103777
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accuracy of soft tissue balancing in total knee arthroplasty using surgeon-defined assessment versus a gap-balancer or electronic sensor.
    Zhao R; Liu Y; Tian H
    J Orthop Surg Res; 2021 May; 16(1):305. PubMed ID: 33964958
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A load-measuring device can achieve fine-tuning of mediolateral load at knee arthroplasty but may lead to a more lax knee state.
    Manning WA; Blain A; Longstaff L; Deehan DJ
    Knee Surg Sports Traumatol Arthrosc; 2019 Jul; 27(7):2238-2250. PubMed ID: 30288569
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Is patella eversion during total knee arthroplasty crucial for gap adjustment and soft-tissue balancing?
    Kamei G; Murakami Y; Kazusa H; Hachisuka S; Inoue H; Nobutou H; Nishida K; Mochizuki Y; Ochi M
    Orthop Traumatol Surg Res; 2011 May; 97(3):287-91. PubMed ID: 21458400
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Relatively Loose Flexion Gap Improves Patient-Reported Clinical Scores in Cruciate-Retaining Total Knee Arthroplasty.
    Matsumoto T; Takayama K; Muratsu H; Ishida K; Hashimoto S; Hayashi S; Kuroda R
    J Knee Surg; 2018 Jul; 31(6):573-579. PubMed ID: 28756614
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Second-Generation Electronic Ligament Balancing for Knee Arthroplasty: A Cadaver Study.
    Nielsen ES; Hsu A; Patil S; Colwell CW; D'Lima DD
    J Arthroplasty; 2018 Jul; 33(7):2293-2300. PubMed ID: 29555494
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Intraoperative pressure sensors improve soft-tissue balance but not clinical outcomes in total knee arthroplasty: a multicentre randomized controlled trial.
    MacDessi SJ; Wood JA; Diwan A; Harris IA;
    Bone Joint J; 2022 May; 104-B(5):604-612. PubMed ID: 35491577
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Does soft tissue balancing using intraoperative pressure sensors improve clinical outcomes in total knee arthroplasty? A protocol of a multicentre randomised controlled trial.
    MacDessi SJ; Bhimani A; Burns AWR; Chen DB; Leong AKL; Molnar RB; Mulford JS; Walker RM; Harris IA; Diwan A; Wood JA
    BMJ Open; 2019 May; 9(5):e027812. PubMed ID: 31079087
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Influence of patellar subluxation on ligament balancing in total knee arthroplasty through a subvastus approach. An in vivo study.
    De Keyser W; Beckers L
    Acta Orthop Belg; 2010 Dec; 76(6):799-805. PubMed ID: 21302579
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Patellofemoral arthroplasty versus total knee arthroplasty for patients with patellofemoral osteoarthritis: equal function and satisfaction but higher revision rate for partial arthroplasty at a minimum eight years’ follow-up.
    Clement ND; Howard TA; Immelman RJ; MacDonald D; Patton JT; Lawson GM; Burnett R
    Bone Joint J; 2019 Jan; 101-B(1):41-46. PubMed ID: 30601045
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Distinctions of introarticular force distribution between genesis-II posterior stabilized and cruciate retaining total knee arthroplasty: An intraoperative comparative study of 45 patients.
    Tang H; Chen H; Yang D; Jiang Y; Zhang C; Zhou Y
    Clin Biomech (Bristol, Avon); 2017 Feb; 42():1-8. PubMed ID: 28042976
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.