These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 29459580)

  • 1. Research on the axial velocity change rule of desktop slot exhaust hood.
    Chen J
    Ind Health; 2018 Jul; 56(4):278-284. PubMed ID: 29459580
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Relationship between physical configuration of hood and velocity for local exhaust systems].
    Ishidao T; Ishimatsu S; Hori H
    J UOEH; 2011 Dec; 33(4):331-6. PubMed ID: 22259838
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Airflow equation of a slot hood by the least square method].
    Ojima J
    Sangyo Eiseigaku Zasshi; 2012; 54(3):108-13. PubMed ID: 22869202
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Design of a circular slot hood for a local exhaust system and its application to a mixing process for fine particles and organic solvents.
    Iwasaki T; Ojima J
    Ind Health; 1997; 35(1):135-42. PubMed ID: 9009512
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Center-Line Velocity Change Regime in a Parallel-Flow Square Exhaust Hood.
    Chen J; Jin L; Chen Z; Yang B; Sun Y; Zhou S
    Int J Environ Res Public Health; 2020 Jun; 17(12):. PubMed ID: 32580455
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effects of boundary-layer separation controllers on a desktop fume hood.
    Huang RF; Chen JK; Hsu CM; Hung SF
    J Occup Environ Hyg; 2016 Oct; 13(10):802-15. PubMed ID: 27104797
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Experimental validation of potential and turbulent flow models for a two-dimensional jet enhanced exhaust hood.
    Kulmala I
    AIHAJ; 2000; 61(2):183-91. PubMed ID: 10782190
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Flow and containment characteristics of a sash-less, variable-height inclined air-curtain fume hood.
    Huang RF; Chen JK; Hung WL
    Ann Occup Hyg; 2013 Aug; 57(7):934-52. PubMed ID: 23519947
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Research on the relationship between the centerline velocity, aspect ratio and exhaust airflow rate for a slot and a rectangular capture hood in an local exhaust ventilation system.
    Tian B; Kubota Y; Murata M
    Ind Health; 2023 Jun; 61(3):222-231. PubMed ID: 35675990
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An analytical, numerical, and experimental comparison of the fluid velocity in the vicinity of an open tank with one and two lateral exhaust slot hoods and a uniform crossdraft.
    Conroy LM; Trevelyan PM; Ingham DB
    Ann Occup Hyg; 2000 Sep; 44(6):407-19. PubMed ID: 10963705
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Simulations of dust dynamics around a cone hood in updraft conditions.
    Logachev KI; Ziganshin AM; Averkova OA
    J Occup Environ Hyg; 2018 Oct; 15(10):715-731. PubMed ID: 30024838
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Development and characterization of an inclined air-curtain (IAC) fume hood.
    Huang RF; Chen JK; Tang KC
    Ann Occup Hyg; 2015 Jun; 59(5):655-67. PubMed ID: 25690760
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Effect of cross current due to worker's arm movement on local exhaust ventilation hood].
    Ojima J
    J UOEH; 2005 Sep; 27(3):273-8. PubMed ID: 16180514
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Orthogonal design on range hood with air curtain and its effects on kitchen environment.
    Liu X; Wang X; Xi G
    J Occup Environ Hyg; 2014; 11(3):186-99. PubMed ID: 24521068
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Research on a push-pull industrial trough-side exhaust hood based on CFD simulation and experiment.
    Song Y; Chen X; Zhang Z; Cao S; Du T; Guo H
    Sci Total Environ; 2022 Jun; 827():154265. PubMed ID: 35259371
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dynamic effects on containment of air-curtain fume hood operated with heat source.
    Chen JK; Huang RF; Hsin PY
    J Occup Environ Hyg; 2012; 9(11):640-52. PubMed ID: 23009207
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Flow characteristics of an inclined air-curtain range hood in a draft.
    Chen JK
    Ind Health; 2015; 53(4):346-53. PubMed ID: 25810445
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Development and characterization of an inclined quad-vortex range hood.
    Huang RF; Chen JK; Lee JH
    Ann Occup Hyg; 2013 Nov; 57(9):1189-99. PubMed ID: 23831934
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Changing Patterns of the Flow Ratio with the Distance of Exhaust and Supply Hood in a Parallel Square Push-Pull Ventilation.
    Chen J
    Int J Environ Res Public Health; 2022 Mar; 19(5):. PubMed ID: 35270650
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Flow characteristics and spillage mechanisms of an inclined quad-vortex range hood subject to influence from draft.
    Huang RF; Chen JK; Lin JH
    J Occup Environ Hyg; 2015; 12(4):235-44. PubMed ID: 25436893
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.