These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 29463984)

  • 41. Image reconstruction by regularized nonlinear inversion--joint estimation of coil sensitivities and image content.
    Uecker M; Hohage T; Block KT; Frahm J
    Magn Reson Med; 2008 Sep; 60(3):674-82. PubMed ID: 18683237
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Phase-constrained parallel MR image reconstruction.
    Willig-Onwuachi JD; Yeh EN; Grant AK; Ohliger MA; McKenzie CA; Sodickson DK
    J Magn Reson; 2005 Oct; 176(2):187-98. PubMed ID: 16027017
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Improving GRAPPA reconstruction using joint nonlinear kernel mapped and phase conjugated virtual coils.
    Wang H; Jia S; Chang Y; Zhu Y; Zou C; Li Y; Liu X; Zheng H; Liang D
    Phys Med Biol; 2019 Jul; 64(14):14NT01. PubMed ID: 31167169
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Adaptive fixed-point iterative shrinkage/thresholding algorithm for MR imaging reconstruction using compressed sensing.
    Wu G; Luo S
    Magn Reson Imaging; 2014 May; 32(4):372-8. PubMed ID: 24512794
    [TBL] [Abstract][Full Text] [Related]  

  • 45. GPU-based iterative cone-beam CT reconstruction using tight frame regularization.
    Jia X; Dong B; Lou Y; Jiang SB
    Phys Med Biol; 2011 Jul; 56(13):3787-807. PubMed ID: 21628778
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Towards the clinical implementation of iterative low-dose cone-beam CT reconstruction in image-guided radiation therapy: cone/ring artifact correction and multiple GPU implementation.
    Yan H; Wang X; Shi F; Bai T; Folkerts M; Cervino L; Jiang SB; Jia X
    Med Phys; 2014 Nov; 41(11):111912. PubMed ID: 25370645
    [TBL] [Abstract][Full Text] [Related]  

  • 47. k-space inherited parallel acquisition (KIPA): application on dynamic magnetic resonance imaging thermometry.
    Guo JY; Kholmovski EG; Zhang L; Jeong EK; Parker DL
    Magn Reson Imaging; 2006 Sep; 24(7):903-15. PubMed ID: 16916708
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Spatio-temporal wavelet regularization for parallel MRI reconstruction: application to functional MRI.
    Chaari L; Ciuciu P; Mériaux S; Pesquet JC
    MAGMA; 2014 Dec; 27(6):509-29. PubMed ID: 24619431
    [TBL] [Abstract][Full Text] [Related]  

  • 49. GPU-accelerated Double-stage Delay-multiply-and-sum Algorithm for Fast Photoacoustic Tomography Using LED Excitation and Linear Arrays.
    Miri Rostami SR; Mozaffarzadeh M; Ghaffari-Miab M; Hariri A; Jokerst J
    Ultrason Imaging; 2019 Sep; 41(5):301-316. PubMed ID: 31322057
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Implementation and performance evaluation of reconstruction algorithms on graphics processors.
    Castaño Díez D; Mueller H; Frangakis AS
    J Struct Biol; 2007 Jan; 157(1):288-95. PubMed ID: 17029985
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Accelerated dynamic MRI using patch regularization for implicit motion compensation.
    Mohsin YQ; Lingala SG; DiBella E; Jacob M
    Magn Reson Med; 2017 Mar; 77(3):1238-1248. PubMed ID: 27091812
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Sparsity-constrained SENSE reconstruction: an efficient implementation using a fast composite splitting algorithm.
    Jiang M; Jin J; Liu F; Yu Y; Xia L; Wang Y; Crozier S
    Magn Reson Imaging; 2013 Sep; 31(7):1218-27. PubMed ID: 23684962
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Optimization and validation of accelerated golden-angle radial sparse MRI reconstruction with self-calibrating GRAPPA operator gridding.
    Benkert T; Tian Y; Huang C; DiBella EVR; Chandarana H; Feng L
    Magn Reson Med; 2018 Jul; 80(1):286-293. PubMed ID: 29193380
    [TBL] [Abstract][Full Text] [Related]  

  • 54. GPU accelerated FDTD solver and its application in MRI.
    Chi J; Liu F; Jin J; Mason DG; Crozier S
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():3305-8. PubMed ID: 21096818
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Real-time flow with fast GPU reconstruction for continuous assessment of cardiac output.
    Kowalik GT; Steeden JA; Pandya B; Odille F; Atkinson D; Taylor A; Muthurangu V
    J Magn Reson Imaging; 2012 Dec; 36(6):1477-82. PubMed ID: 22745017
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Super-resolved parallel MRI by spatiotemporal encoding.
    Schmidt R; Baishya B; Ben-Eliezer N; Seginer A; Frydman L
    Magn Reson Imaging; 2014 Jan; 32(1):60-70. PubMed ID: 24120293
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Velocity vector reconstruction for real-time phase-contrast MRI with radial Maxwell correction.
    Kollmeier JM; Kalentev O; Klosowski J; Voit D; Frahm J
    Magn Reson Med; 2022 Apr; 87(4):1863-1875. PubMed ID: 34850452
    [TBL] [Abstract][Full Text] [Related]  

  • 58. A review of GPU-based medical image reconstruction.
    Després P; Jia X
    Phys Med; 2017 Oct; 42():76-92. PubMed ID: 29173924
    [TBL] [Abstract][Full Text] [Related]  

  • 59. An iterative reduced field-of-view reconstruction for periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) MRI.
    Lin JM; Patterson AJ; Chang HC; Gillard JH; Graves MJ
    Med Phys; 2015 Oct; 42(10):5757-67. PubMed ID: 26429249
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Accelerated fast iterative shrinkage thresholding algorithms for sparsity-regularized cone-beam CT image reconstruction.
    Xu Q; Yang D; Tan J; Sawatzky A; Anastasio MA
    Med Phys; 2016 Apr; 43(4):1849. PubMed ID: 27036582
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.