BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

167 related articles for article (PubMed ID: 29472089)

  • 1. Investigation of the XCAT phantom as a validation tool in cardiac MRI tracking algorithms.
    Lowther N; Ipsen S; Marsh S; Blanck O; Keall P
    Phys Med; 2018 Jan; 45():44-51. PubMed ID: 29472089
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Towards real-time MRI-guided 3D localization of deforming targets for non-invasive cardiac radiosurgery.
    Ipsen S; Blanck O; Lowther NJ; Liney GP; Rai R; Bode F; Dunst J; Schweikard A; Keall PJ
    Phys Med Biol; 2016 Nov; 61(22):7848-7863. PubMed ID: 27779127
    [TBL] [Abstract][Full Text] [Related]  

  • 3. End-to-end validation of fiducial tracking accuracy in robotic radiosurgery using MRI-only simulation imaging.
    Singhrao K; Zubair M; Nano T; Scholey JE; Descovich M
    Med Phys; 2024 Jan; 51(1):31-41. PubMed ID: 38055419
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Radiotherapy beyond cancer: target localization in real-time MRI and treatment planning for cardiac radiosurgery.
    Ipsen S; Blanck O; Oborn B; Bode F; Liney G; Hunold P; Rades D; Schweikard A; Keall PJ
    Med Phys; 2014 Dec; 41(12):120702. PubMed ID: 25471947
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of an active magnetic resonance tracking system for interstitial brachytherapy.
    Wang W; Viswanathan AN; Damato AL; Chen Y; Tse Z; Pan L; Tokuda J; Seethamraju RT; Dumoulin CL; Schmidt EJ; Cormack RA
    Med Phys; 2015 Dec; 42(12):7114-21. PubMed ID: 26632065
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Geometric validation of self-gating k-space-sorted 4D-MRI vs 4D-CT using a respiratory motion phantom.
    Yue Y; Fan Z; Yang W; Pang J; Deng Z; McKenzie E; Tuli R; Wallace R; Li D; Fraass B
    Med Phys; 2015 Oct; 42(10):5787-97. PubMed ID: 26429253
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Development of system using beam's eye view images to measure respiratory motion tracking errors in image-guided robotic radiosurgery system.
    Inoue M; Shiomi H; Iwata H; Taguchi J; Okawa K; Kikuchi C; Inada K; Iwabuchi M; Murai T; Koike I; Tatewaki K; Ohta S; Inoue T
    J Appl Clin Med Phys; 2015 Jan; 16(1):5049. PubMed ID: 25679160
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Four dimensional magnetic resonance imaging with retrospective k-space reordering: a feasibility study.
    Liu Y; Yin FF; Chen NK; Chu ML; Cai J
    Med Phys; 2015 Feb; 42(2):534-41. PubMed ID: 25652474
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Image-based retrospective 4D MRI in external beam radiotherapy: A comparative study with a digital phantom.
    Paganelli C; Kipritidis J; Lee D; Baroni G; Keall P; Riboldi M
    Med Phys; 2018 Jul; 45(7):3161-3172. PubMed ID: 29757471
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Feasibility of real-time motion tracking using cine MRI during MR-guided radiation therapy for abdominal targets.
    Keiper TD; Tai A; Chen X; Paulson E; Lathuilière F; Bériault S; Hébert F; Cooper DT; Lachaine M; Li XA
    Med Phys; 2020 Aug; 47(8):3554-3566. PubMed ID: 32402111
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Tracking tumor boundary in MV-EPID images without implanted markers: A feasibility study.
    Zhang X; Homma N; Ichiji K; Takai Y; Yoshizawa M
    Med Phys; 2015 May; 42(5):2510-23. PubMed ID: 25979044
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Characterizing spatiotemporal information loss in sparse-sampling-based dynamic MRI for monitoring respiration-induced tumor motion in radiotherapy.
    Arai TJ; Nofiele J; Madhuranthakam AJ; Yuan Q; Pedrosa I; Chopra R; Sawant A
    Med Phys; 2016 Jun; 43(6):2807-2820. PubMed ID: 27277029
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A generative adversarial network (GAN)-based technique for synthesizing realistic respiratory motion in the extended cardiac-torso (XCAT) phantoms.
    Chang Y; Jiang Z; Segars WP; Zhang Z; Lafata K; Cai J; Yin FF; Ren L
    Phys Med Biol; 2021 May; 66(11):. PubMed ID: 34061044
    [No Abstract]   [Full Text] [Related]  

  • 14. The potential of positron emission tomography for intratreatment dynamic lung tumor tracking: a phantom study.
    Yang J; Yamamoto T; Mazin SR; Graves EE; Keall PJ
    Med Phys; 2014 Feb; 41(2):021718. PubMed ID: 24506609
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Cardiac motion correction based on partial angle reconstructed images in x-ray CT.
    Kim S; Chang Y; Ra JB
    Med Phys; 2015 May; 42(5):2560-71. PubMed ID: 25979048
    [TBL] [Abstract][Full Text] [Related]  

  • 16. 3D delivered dose assessment using a 4DCT-based motion model.
    Cai W; Hurwitz MH; Williams CL; Dhou S; Berbeco RI; Seco J; Mishra P; Lewis JH
    Med Phys; 2015 Jun; 42(6):2897-907. PubMed ID: 26127043
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of image guided motion management methods in lung cancer radiotherapy.
    Zhuang L; Yan D; Liang J; Ionascu D; Mangona V; Yang K; Zhou J
    Med Phys; 2014 Mar; 41(3):031911. PubMed ID: 24593729
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Time-resolved volumetric MRI in MRI-guided radiotherapy: an in silico comparative analysis.
    Paganelli C; Portoso S; Garau N; Meschini G; Via R; Buizza G; Keall P; Riboldi M; Baroni G
    Phys Med Biol; 2019 Sep; 64(18):185013. PubMed ID: 31323645
    [TBL] [Abstract][Full Text] [Related]  

  • 19. SU-E-J-145: Implementing 4D XCAT Phantom for 4D Radiotherapy Research.
    Panta R; Segars W; Yin F; Cai J
    Med Phys; 2012 Jun; 39(6Part8):3686. PubMed ID: 28518892
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Three-dimensional liver motion tracking using real-time two-dimensional MRI.
    Brix L; Ringgaard S; Sørensen TS; Poulsen PR
    Med Phys; 2014 Apr; 41(4):042302. PubMed ID: 24694152
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.