137 related articles for article (PubMed ID: 29479737)
1. Single-scan z-shim method for reducing susceptibility artifacts in gradient echo myelin water imaging.
Lee D; Lee J; Lee J; Nam Y
Magn Reson Med; 2018 Sep; 80(3):1101-1109. PubMed ID: 29479737
[No Abstract] [Full Text] [Related]
2. Wave-CAIPI ViSTa: highly accelerated whole-brain direct myelin water imaging with zero-padding reconstruction.
Wu Z; Bilgic B; He H; Tong Q; Sun Y; Du Y; Setsompop K; Zhong J
Magn Reson Med; 2018 Sep; 80(3):1061-1073. PubMed ID: 29388254
[No Abstract] [Full Text] [Related]
3. Field inhomogeneity correction for gradient echo myelin water fraction imaging.
Alonso-Ortiz E; Levesque IR; Paquin R; Pike GB
Magn Reson Med; 2017 Jul; 78(1):49-57. PubMed ID: 27416957
[TBL] [Abstract][Full Text] [Related]
4. Real-time feedback optimization of z-shim gradient for automatic compensation of susceptibility-induced signal loss in EPI.
Tang YW; Huang TY
Neuroimage; 2011 Apr; 55(4):1587-92. PubMed ID: 21256230
[TBL] [Abstract][Full Text] [Related]
5. Improved three-dimensional multi-echo gradient echo based myelin water fraction mapping with phase related artifact correction.
Lee H; Nam Y; Lee HJ; Hsu JJ; Henry RG; Kim DH
Neuroimage; 2018 Apr; 169():1-10. PubMed ID: 29191477
[TBL] [Abstract][Full Text] [Related]
6. Single-shot interleaved z-shim EPI with optimized compensation for signal losses due to susceptibility-induced field inhomogeneity at 3 T.
Gu H; Feng H; Zhan W; Xu S; Silbersweig DA; Stern E; Yang Y
Neuroimage; 2002 Nov; 17(3):1358-64. PubMed ID: 12414275
[TBL] [Abstract][Full Text] [Related]
7. Echo time-range effects on gradient-echo based myelin water fraction mapping at 3T.
Lee H; Nam Y; Kim DH
Magn Reson Med; 2019 Apr; 81(4):2799-2807. PubMed ID: 30346049
[TBL] [Abstract][Full Text] [Related]
8. Inversion recovery UTE based volumetric myelin imaging in human brain using interleaved hybrid encoding.
Jang H; Ma Y; Searleman AC; Carl M; Corey-Bloom J; Chang EY; Du J
Magn Reson Med; 2020 Mar; 83(3):950-961. PubMed ID: 31532032
[TBL] [Abstract][Full Text] [Related]
9. Diffusion-weighted echo planar MR imaging of the neck at 3 T using integrated shimming: comparison of MR sequence techniques for reducing artifacts caused by magnetic-field inhomogeneities.
Gatidis S; Graf H; Weiß J; Stemmer A; Kiefer B; Nikolaou K; Notohamiprodjo M; Martirosian P
MAGMA; 2017 Feb; 30(1):57-63. PubMed ID: 27503308
[TBL] [Abstract][Full Text] [Related]
10. Simultaneous z-shim method for reducing susceptibility artifacts with multiple transmitters.
Deng W; Yang C; Alagappan V; Wald LL; Boada FE; Stenger VA
Magn Reson Med; 2009 Feb; 61(2):255-9. PubMed ID: 19165881
[TBL] [Abstract][Full Text] [Related]
11. Autofocusing-based phase correction.
Loktyushin A; Ehses P; Schölkopf B; Scheffler K
Magn Reson Med; 2018 Sep; 80(3):958-968. PubMed ID: 29352498
[No Abstract] [Full Text] [Related]
12. Multi-Exponential Relaxometry Using l
Zimmermann M; Oros-Peusquens AM; Iordanishvili E; Shin S; Yun SD; Abbas Z; Shah NJ
IEEE Trans Med Imaging; 2019 Nov; 38(11):2676-2686. PubMed ID: 30990178
[TBL] [Abstract][Full Text] [Related]
13. Variable flip angle echo planar time-resolved imaging (vFA-EPTI) for fast high-resolution gradient echo myelin water imaging.
Dong Z; Wang F; Chan KS; Reese TG; Bilgic B; Marques JP; Setsompop K
Neuroimage; 2021 May; 232():117897. PubMed ID: 33621694
[TBL] [Abstract][Full Text] [Related]
14. Reduction of magnetic field inhomogeneity artifacts in echo planar imaging with SENSE and GESEPI at high field.
Yang QX; Wang J; Smith MB; Meadowcroft M; Sun X; Eslinger PJ; Golay X
Magn Reson Med; 2004 Dec; 52(6):1418-23. PubMed ID: 15562468
[TBL] [Abstract][Full Text] [Related]
15. Simultaneous acquisition of gradient-echo and asymmetric spin-echo for single-shot z-shim: Z-SAGA.
Heberlein KA; Hu X
Magn Reson Med; 2004 Jan; 51(1):212-6. PubMed ID: 14705064
[TBL] [Abstract][Full Text] [Related]
16. Rapid whole cerebrum myelin water imaging using a 3D GRASE sequence.
Prasloski T; Rauscher A; MacKay AL; Hodgson M; Vavasour IM; Laule C; Mädler B
Neuroimage; 2012 Oct; 63(1):533-9. PubMed ID: 22776448
[TBL] [Abstract][Full Text] [Related]
17. Rapid whole-brain quantitative magnetization transfer imaging using 3D selective inversion recovery sequences.
Cronin MJ; Xu J; Bagnato F; Gochberg DF; Gore JC; Dortch RD
Magn Reson Imaging; 2020 May; 68():66-74. PubMed ID: 32004710
[TBL] [Abstract][Full Text] [Related]
18. Volumetric R2 * mapping using z-shim multi-echo gradient echo imaging.
Han D; Nam Y; Gho SM; Kim DH
Magn Reson Med; 2015 Mar; 73(3):1164-70. PubMed ID: 24664576
[TBL] [Abstract][Full Text] [Related]
19. Parallel imaging with asymmetric acceleration to reduce Gibbs artifacts and to increase signal-to-noise ratio of the gradient echo echo-planar imaging sequence for functional MRI.
Jung KJ; Zhao T
Magn Reson Med; 2012 Feb; 67(2):419-27. PubMed ID: 21713976
[TBL] [Abstract][Full Text] [Related]
20. Multi-gradient-echo myelin water fraction imaging: Comparison to the multi-echo-spin-echo technique.
Alonso-Ortiz E; Levesque IR; Pike GB
Magn Reson Med; 2018 Mar; 79(3):1439-1446. PubMed ID: 28656649
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]