BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

254 related articles for article (PubMed ID: 29488887)

  • 1. Novel predictors of mild paravalvular aortic regurgitation in SAPIEN 3 transcatheter aortic valve implantation.
    Tang GHL; Zaid S; Schnittman SR; Ahmad H; Kaple R; Undemir C; Dutta T; Poniros A; Bennett J; Feng C; Cohen M; Lansman SL
    EuroIntervention; 2018 May; 14(1):58-68. PubMed ID: 29488887
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Paravalvular leak after transcatheter aortic valve implantation: is it anatomically predictable or procedurally determined? MDCT study.
    Sakrana AA; Nasr MM; Ashamallah GA; Abuelatta RA; Naeim HA; Tahlawi ME
    Clin Radiol; 2016 Nov; 71(11):1095-103. PubMed ID: 27612848
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Impact of Aortic Root Anatomy and Geometry on Paravalvular Leak in Transcatheter Aortic Valve Replacement With Extremely Large Annuli Using the Edwards SAPIEN 3 Valve.
    Tang GHL; Zaid S; George I; Khalique OK; Abramowitz Y; Maeno Y; Makkar RR; Jilaihawi H; Kamioka N; Thourani VH; Babaliaros V; Webb JG; Htun NM; Attinger-Toller A; Ahmad H; Kaple R; Sharma K; Kozina JA; Kaneko T; Shah P; Hirji SA; Desai ND; Anwaruddin S; Jagasia D; Herrmann HC; Basra SS; Szerlip MA; Mack MJ; Mathur M; Tan CW; Don CW; Sharma R; Gafoor S; Zhang M; Kapadia SR; Mick SL; Krishnaswamy A; Amoroso N; Salemi A; Wong SC; Kini AS; Rodés-Cabau J; Leon MB; Kodali SK
    JACC Cardiovasc Interv; 2018 Jul; 11(14):1377-1387. PubMed ID: 29960755
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Predictors of Paravalvular Regurgitation After Implantation of the Fully Repositionable and Retrievable Lotus Transcatheter Aortic Valve (from the REPRISE II Trial Extended Cohort).
    Blackman DJ; Meredith IT; Dumonteil N; Tchétché D; Hildick-Smith D; Spence MS; Walters DL; Harnek J; Worthley SG; Rioufol G; Lefèvre T; Houle VM; Allocco DJ; Dawkins KD
    Am J Cardiol; 2017 Jul; 120(2):292-299. PubMed ID: 28535962
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Optimal sizing for SAPIEN 3 transcatheter aortic valve replacement in patients with or without left ventricular outflow tract calcification.
    Maeno Y; Abramowitz Y; Jilaihawi H; Israr S; Yoon S; Sharma RP; Kazuno Y; Kawamori H; Miyasaka M; Rami T; Mangat G; Takahashi N; Okuyama K; Kashif M; Chakravarty T; Nakamura M; Cheng W; Makkar RR
    EuroIntervention; 2017 Apr; 12(18):e2177-e2185. PubMed ID: 28117281
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A revised methodology for aortic-valvar complex calcium quantification for transcatheter aortic valve implantation.
    Jilaihawi H; Makkar RR; Kashif M; Okuyama K; Chakravarty T; Shiota T; Friede G; Nakamura M; Doctor N; Rafique A; Shibayama K; Mihara H; Trento A; Cheng W; Friedman J; Berman D; Fontana GP
    Eur Heart J Cardiovasc Imaging; 2014 Dec; 15(12):1324-32. PubMed ID: 25187618
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Impact of Valve Over-Sizing After Transcatheter Aortic Valve Implantation With a Self-Expanding Valve: A Multislice Computed Tomography Study.
    Drakopoulou M; Toutouzas K; Stathogiannis K; Latsios G; Sideris S; Xanthopoulou M; Penesopoulou V; Trantalis G; Synetos A; Papanikolaou A; Aggeli C; Vavuranakis M; Tousoulis D
    J Invasive Cardiol; 2019 May; 31(5):E76-E82. PubMed ID: 31034438
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Paravalvular leak after transcatheter aortic valve implantation (TAVI): Short-term results. Data from Polish national POL-TAVI registry.
    Kleczyński P; Zasada W; Bagieński M; Rzeszutko Ł; Sorysz D; Sobczyński R; Trębacz J; Kapelak B; Zembala M; Dudek D
    Cardiol J; 2016; 23(2):163-8. PubMed ID: 26503080
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The extent of aortic annulus calcification is a predictor of postprocedural eccentricity and paravalvular regurgitation: a pre- and postinterventional cardiac computed tomography angiography study.
    Bekeredjian R; Bodingbauer D; Hofmann NP; Greiner S; Schuetz M; Geis NA; Kauczor HU; Bryant M; Chorianopoulos E; Pleger ST; Mereles D; Katus HA; Korosoglou G
    J Invasive Cardiol; 2015 Mar; 27(3):172-80. PubMed ID: 25740972
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Balloon Versus Computed Tomography Sizing of the Aortic Annulus for Transcatheter Aortic Valve Replacement and the Impact of Left Ventricular Outflow Tract Calcification and Morphology on Sizing.
    Condado JF; Lerakis S; Stewart J; Jensen H; Henry TS; Ko SM; Stillman A; Rajaei MH; Mavromatis K; Devireddy C; Sarin E; Leshnower B; Guyton R; Kaebnick B; Thourani VH; Block PC; Babaliaros V
    J Invasive Cardiol; 2016 Jul; 28(7):295-304. PubMed ID: 27101969
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Incidence, Predictors, and Outcome of Paravalvular Leak after Transcatheter Aortic Valve Implantation.
    Hagar A; Li Y; Wei X; Peng Y; Xu Y; Ou Y; Wang Z; Wang X; Shah JP; Sihag V; Chen M; Feng Y
    J Interv Cardiol; 2020; 2020():8249497. PubMed ID: 32523474
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Predictors of Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation for Aortic Stenosis Using New-Generation Balloon-Expandable SAPIEN 3.
    Kaneko H; Hoelschermann F; Tambor G; Yoon SH; Neuss M; Butter C
    Am J Cardiol; 2017 Feb; 119(4):618-622. PubMed ID: 28010874
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Risk factors for paravalvular leak after transcatheter aortic valve replacement.
    Pollari F; Dell'Aquila AM; Söhn C; Marianowicz J; Wiehofsky P; Schwab J; Pauschinger M; Hitzl W; Fischlein T; Pfeiffer S
    J Thorac Cardiovasc Surg; 2019 Apr; 157(4):1406-1415.e3. PubMed ID: 30482527
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Anatomical risk models for paravalvular leak and landing zone complications for balloon-expandable transcatheter aortic valve replacement.
    Condado JF; Corrigan FE; Lerakis S; Parastatidis I; Stillman AE; Binongo JN; Stewart J; Mavromatis K; Devireddy C; Leshnower B; Guyton R; Forcillo J; Patel A; Thourani VH; Block PC; Babaliaros V
    Catheter Cardiovasc Interv; 2017 Oct; 90(4):690-700. PubMed ID: 28471092
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Predictors of paravalvular leak following implantation of the ACURATE neo transcatheter heart valve: the PREDICT PVL study.
    Brinkert M; De Boeck B; Stämpfli SF; Wolfrum M; Moccetti F; Attinger-Toller A; Bossard M; Cuculi F; Kobza R; Toggweiler S
    Open Heart; 2020 Nov; 7(2):. PubMed ID: 33243930
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Can we predict postprocedural paravalvular leak after Edwards SAPIEN transcatheter aortic valve implantation?
    Watanabe Y; Lefèvre T; Arai T; Hayashida K; Bouvier E; Hovasse T; Romano M; Chevalier B; Garot P; Donzeau-Gouge P; Farge A; Cormier B; Morice MC
    Catheter Cardiovasc Interv; 2015 Jul; 86(1):144-51. PubMed ID: 25205469
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Does pre-existing aortic regurgitation protect from death in patients who develop paravalvular leak after TAVI?
    Colli A; Besola L; Salizzoni S; Gregori D; Tarantini G; Agrifoglio M; Chieffo A; Regesta T; Gabbieri D; Saia F; Tamburino C; Ribichini F; Valsecchi O; Loi B; Iadanza A; Stolcova M; Minati A; Martinelli G; Bedogni F; Petronio A; Dallago M; Cappai A; D'Onofrio A; Gerosa G; Rinaldi M
    Int J Cardiol; 2017 Apr; 233():52-60. PubMed ID: 28188002
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of Edwards SAPIEN 3 versus SAPIEN XT in transfemoral transcatheter aortic valve implantation: Difference of valve selection in the real world.
    Arai T; Lefèvre T; Hovasse T; Morice MC; Garot P; Benamer H; Unterseeh T; Hayashida K; Watanabe Y; Bouvier E; Cormier B; Chevalier B
    J Cardiol; 2017 Mar; 69(3):565-569. PubMed ID: 27288330
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Overexpansion of the 29 mm SAPIEN 3 transcatheter heart valve in patients with large aortic annuli (area > 683 mm
    Mathur M; McCabe JM; Aldea G; Pal J; Don CW
    Catheter Cardiovasc Interv; 2018 May; 91(6):1149-1156. PubMed ID: 28836337
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Quantitative Prediction of Paravalvular Leak in Transcatheter Aortic Valve Replacement Based on Tissue-Mimicking 3D Printing.
    Qian Z; Wang K; Liu S; Zhou X; Rajagopal V; Meduri C; Kauten JR; Chang YH; Wu C; Zhang C; Wang B; Vannan MA
    JACC Cardiovasc Imaging; 2017 Jul; 10(7):719-731. PubMed ID: 28683947
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.