144 related articles for article (PubMed ID: 29496321)
1. Stability of Cefazolin in Polyisoprene Elastomeric Infusion Devices.
Patel RP; Jacob J; Sedeeq M; Ming LC; Wanandy T; Zaidi STR; Peterson GM
Clin Ther; 2018 Apr; 40(4):664-667. PubMed ID: 29496321
[TBL] [Abstract][Full Text] [Related]
2. Assessment of the stability of citrate-buffered flucloxacillin for injection when stored in two commercially available ambulatory elastomeric devices: INfusor LV (Baxter) and Accufuser (Woo Young Medical): a study compliant with the NHS Yellow Cover Document (YCD) requirements.
Allwood MC; Stonkute D; Wallace A; Wilkinson AS; Hills T; Jamieson C;
Eur J Hosp Pharm; 2020 Mar; 27(2):90-94. PubMed ID: 32153771
[TBL] [Abstract][Full Text] [Related]
3. Stability of vincristine sulfate, doxorubicin hydrochloride and etoposide phosphate admixtures in polyisoprene elastomeric pump supporting transition of the EPOCH regimen to outpatient care.
Svirskis D; Behera S; Naidoo N; Beachman J; Raina T; Zhou Y; Berkahn L; Costello I; Gu Y
J Oncol Pharm Pract; 2019 Jun; 25(4):831-840. PubMed ID: 29540104
[TBL] [Abstract][Full Text] [Related]
4. An investigation of the stability of meropenem in elastomeric infusion devices.
Foy F; Luna G; Martinez J; Nizich Z; Seet J; Lie K; Sunderland B; Czarniak P
Drug Des Devel Ther; 2019; 13():2655-2665. PubMed ID: 31447546
[TBL] [Abstract][Full Text] [Related]
5. Stability of meropenem in portable elastomeric infusion devices: which protocol should be implemented in clinical practice?
Esteban-Cartelle B; Serrano DR; Pérez Menéndez-Conde C; Vicente-Oliveros N; Álvarez-Díaz A; Abete JF; Martín-Dávila P
Microbiol Spectr; 2024 Feb; 12(2):e0206323. PubMed ID: 38230930
[TBL] [Abstract][Full Text] [Related]
6. Physical and chemical stability of ceftaroline in an elastomeric infusion device.
Al Madfai F; Zaidi STR; Ming LC; Wanandy T; Patel RP
Eur J Hosp Pharm; 2018 Oct; 25(e2):e115-e119. PubMed ID: 31157080
[TBL] [Abstract][Full Text] [Related]
7. Ceftolozane-tazobactam in an elastomeric infusion device for ambulatory care: an in vitro stability study.
Raby E; Naicker S; Sime FB; Manning L; Wallis SC; Pandey S; Roberts JA
Eur J Hosp Pharm; 2020 Mar; 27(e1):e84-e86. PubMed ID: 32296512
[TBL] [Abstract][Full Text] [Related]
8. Antibiotic stability related to temperature variations in elastomeric pumps used for outpatient parenteral antimicrobial therapy (OPAT).
Voumard R; Van Neyghem N; Cochet C; Gardiol C; Decosterd L; Buclin T; de Valliere S
J Antimicrob Chemother; 2017 May; 72(5):1462-1465. PubMed ID: 28158637
[TBL] [Abstract][Full Text] [Related]
9. Elastomeric pump reliability in postoperative regional anesthesia: a survey of 430 consecutive devices.
Remerand F; Vuitton AS; Palud M; Buchet S; Pourrat X; Baud A; Laffon M; Fusciardi J
Anesth Analg; 2008 Dec; 107(6):2079-84. PubMed ID: 19020162
[TBL] [Abstract][Full Text] [Related]
10. Stability of the combination of ceftazidime and cephazolin in icodextrin or pH neutral peritoneal dialysis solution.
Patel RP; Shastri MD; Bakkari M; Wanandy T; Jose MD
Perit Dial Int; 2014; 34(2):212-8. PubMed ID: 24385326
[TBL] [Abstract][Full Text] [Related]
11. Stability of dobutamine in continuous ambulatory delivery devices.
Al Madfai F; Valah B; Zaidi STR; Wanandy T; Ming LC; Peterson GM; Patel RP
J Clin Pharm Ther; 2018 Aug; 43(4):530-535. PubMed ID: 29500838
[TBL] [Abstract][Full Text] [Related]
12. Physicochemical stability of voriconazole in elastomeric devices.
Harmanjeet H; Zaidi STR; Ming LC; Wanandy T; Patel RP
Eur J Hosp Pharm; 2018 Oct; 25(e2):e88-e92. PubMed ID: 31157075
[TBL] [Abstract][Full Text] [Related]
13. Stability of cefazolin sodium and metronidazole at 8 degrees C for use as an i.v. admixture.
Rivers TE; McBride HA; Trang JM
J Parenter Sci Technol; 1993; 47(3):135-7. PubMed ID: 8360806
[TBL] [Abstract][Full Text] [Related]
14. Stability of benzylpenicillin potassium and ampicillin in an elastomeric infusion pump.
Nakamura T; Enoki Y; Uno S; Uwamino Y; Iketani O; Hasegawa N; Matsumoto K
J Infect Chemother; 2018 Oct; 24(10):856-859. PubMed ID: 29705391
[TBL] [Abstract][Full Text] [Related]
15. Stability of antimicrobial agents in an elastomeric infusion pump used for outpatient parenteral antimicrobial therapy.
Akahane M; Enoki Y; Saiki R; Hayashi Y; Hiraoka K; Honma K; Itagaki M; Gotoda M; Shinoda K; Hanyu S; Hamamura Y; Miyajima T; Ito C; Taguchi K; Uno S; Uwamino Y; Iketani O; Hasegawa N; Matsumoto K
Int J Infect Dis; 2021 Feb; 103():464-468. PubMed ID: 33246042
[TBL] [Abstract][Full Text] [Related]
16. Stability of colistimethate sodium in a disposable elastomeric infusion device.
Abdulla A; van Leeuwen RW; de Vries Schultink AH; Koch BC
Int J Pharm; 2015; 486(1-2):367-9. PubMed ID: 25863116
[TBL] [Abstract][Full Text] [Related]
17. [In vitro study of the flow duration of antibiotics solutions prepared in elastomeric infusion devices: effect of cold storage for 3 to 7days].
Grangeon-Chapon C; Robein-Dobremez MJ; Pin I; Trouiller P; Allenet B; Foroni L
Ann Pharm Fr; 2015 Sep; 73(5):378-90. PubMed ID: 25721763
[TBL] [Abstract][Full Text] [Related]
18. Protocol for a randomised crossover trial to evaluate patient and nurse satisfaction with electronic and elastomeric portable infusion pumps for the continuous administration of antibiotic therapy in the home: the Comparing Home Infusion Devices (CHID) study.
Hobbs JG; Ryan MK; Ritchie B; Sluggett JK; Sluggett AJ; Ralton L; Reynolds KJ
BMJ Open; 2017 Jul; 7(7):e016763. PubMed ID: 28760798
[TBL] [Abstract][Full Text] [Related]
19. Stability of cefazolin sodium in peritoneal dialysis solutions.
Nahata MC; Ahalt PA
Am J Hosp Pharm; 1991 Feb; 48(2):291-2. PubMed ID: 2003503
[TBL] [Abstract][Full Text] [Related]
20. Compatibility and stability of linezolid injection admixed with three cephalosporin antibiotics.
Xu QA; Trissel LA; Williams KY
J Am Pharm Assoc (Wash); 2000; 40(4):509-14. PubMed ID: 10932460
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]