BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 29504248)

  • 1. ANSYS-MATLAB co-simulation of mucus flow distribution and clearance effectiveness of a new simulated cough device.
    Ren S; Shi Y; Cai M; Zhao H; Zhang Z; Zhang XD
    Int J Numer Method Biomed Eng; 2018 Jun; 34(6):e2978. PubMed ID: 29504248
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Numerical Analysis of Airway Mucus Clearance Effectiveness Using Assisted Coughing Techniques.
    Ren S; Li W; Wang L; Shi Y; Cai M; Hao L; Luo Z; Niu J; Xu W; Luo Z
    Sci Rep; 2020 Feb; 10(1):2030. PubMed ID: 32029825
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Glottis effects on the cough clearance process simulated with a CFD dynamic mesh and Eulerian wall film model.
    Paz C; Suárez E; Parga O; Vence J
    Comput Methods Biomech Biomed Engin; 2017 Sep; 20(12):1326-1338. PubMed ID: 28782386
    [TBL] [Abstract][Full Text] [Related]  

  • 4. CFD transient simulation of the cough clearance process using an Eulerian wall film model.
    Paz C; Suárez E; Vence J
    Comput Methods Biomech Biomed Engin; 2017 Feb; 20(2):142-152. PubMed ID: 27380322
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Analysis of the volume of fluid (VOF) method for the simulation of the mucus clearance process with CFD.
    Paz C; Suárez E; Vence J; Cabarcos A
    Comput Methods Biomech Biomed Engin; 2019 Apr; 22(5):547-566. PubMed ID: 30773045
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Relationship between peak cough flow and spirometry in Duchenne muscular dystrophy.
    Gauld LM; Boynton A
    Pediatr Pulmonol; 2005 May; 39(5):457-60. PubMed ID: 15765540
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Airway Clearance With an Optimized Mechanical Insufflation-Exsufflation Maneuver.
    Volpe MS; Naves JM; Ribeiro GG; Ruas G; Amato MBP
    Respir Care; 2018 Oct; 63(10):1214-1222. PubMed ID: 30018177
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Could reflex cough induced through nebulized capsaicin achieve airway clearance in patients with acute retention of lung secretions?
    Kulnik ST
    Med Hypotheses; 2018 Oct; 119():104-109. PubMed ID: 30122479
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The mechanism of mucus clearance in cough.
    Basser PJ; McMahon TA; Griffith P
    J Biomech Eng; 1989 Nov; 111(4):288-97. PubMed ID: 2486367
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Role of simulated repetitive coughing in mucus clearance.
    Zahm JM; King M; Duvivier C; Pierrot D; Girod S; Puchelle E
    Eur Respir J; 1991 Mar; 4(3):311-5. PubMed ID: 1864345
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cough Effectiveness and Pulmonary Hygiene Practices in Patients with Pompe Disease.
    Pitts T; Bordelon R; Huff A; Byrne BJ; Smith BK
    Lung; 2019 Feb; 197(1):1-8. PubMed ID: 30361764
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of airway wall flexibility on clearance by simulated cough.
    Soland V; Brock G; King M
    J Appl Physiol (1985); 1987 Aug; 63(2):707-12. PubMed ID: 3654431
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The role of mucus gel viscosity, spinnability, and adhesive properties in clearance by simulated cough.
    King M; Zahm JM; Pierrot D; Vaquez-Girod S; Puchelle E
    Biorheology; 1989; 26(4):737-45. PubMed ID: 2611367
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Computational Modelling of Cough Function and Airway Penetrant Behavior in Patients with Disorders of Laryngeal Function.
    Hoffman Ruddy B; Nadun Kuruppumullage D; Carnaby G; Crary M; Lehman J; Ilegbusi OJ
    Laryngoscope Investig Otolaryngol; 2017 Feb; 2(1):23-29. PubMed ID: 28894819
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Interactions of airflow oscillation, tracheal inclination, and mucus elasticity significantly improve simulated cough clearance.
    Ragavan AJ; Evrensel CA; Krumpe P
    Chest; 2010 Feb; 137(2):355-61. PubMed ID: 19762551
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Rôle of mucus viscoelasticity in clearance by cough.
    King M
    Eur J Respir Dis Suppl; 1987; 153():165-72. PubMed ID: 3480813
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of enhanced supramaximal flows on cough clearance.
    Bennett WD; Zeman KL
    J Appl Physiol (1985); 1994 Oct; 77(4):1577-83. PubMed ID: 7836171
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The role of mucus viscoelasticity in cough clearance.
    King M
    Biorheology; 1987; 24(6):589-97. PubMed ID: 3502760
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The role of mucus sol phase in clearance by simulated cough.
    Zahm JM; Pierrot D; Vaquez-Girod S; Duvivier C; King M; Puchelle E
    Biorheology; 1989; 26(4):747-52. PubMed ID: 2611368
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The effect of unproductive coughing/FET on regional mucus movement in the human lungs.
    Hasani A; Pavia D; Agnew JE; Clarke SW
    Respir Med; 1991 Jan; 85 Suppl A():23-6. PubMed ID: 2034831
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.