BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

278 related articles for article (PubMed ID: 29512092)

  • 1. Optical coherence tomography-guided versus angiography-guided implantation of everolimus-eluting bioresorbable vascular scaffolds: Comparison of coverage, apposition and clinical outcome. The ALSTER-OCT ABSORB registry.
    Heeger CH; Schedifka AS; Meincke F; Spangenberg T; Wienemann H; Kreidel F; Kuck KH; Ghanem A; Bergmann MW
    Cardiol J; 2018; 25(4):459-469. PubMed ID: 29512092
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Two-year clinical, angiographic, and serial optical coherence tomographic follow-up after implantation of an everolimus-eluting bioresorbable scaffold and an everolimus-eluting metallic stent: insights from the randomised ABSORB Japan trial.
    Onuma Y; Sotomi Y; Shiomi H; Ozaki Y; Namiki A; Yasuda S; Ueno T; Ando K; Furuya J; Igarashi K; Kozuma K; Tanabe K; Kusano H; Rapoza R; Popma JJ; Stone GW; Simonton C; Serruys PW; Kimura T
    EuroIntervention; 2016 Oct; 12(9):1090-1101. PubMed ID: 27597270
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fate of post-procedural malapposition of everolimus-eluting polymeric bioresorbable scaffold and everolimus-eluting cobalt chromium metallic stent in human coronary arteries: sequential assessment with optical coherence tomography in ABSORB Japan trial.
    Sotomi Y; Onuma Y; Dijkstra J; Miyazaki Y; Kozuma K; Tanabe K; Popma JJ; de Winter RJ; Serruys PW; Kimura T
    Eur Heart J Cardiovasc Imaging; 2018 Jan; 19(1):59-66. PubMed ID: 28158421
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Vascular response and healing profile of everolimus-eluting bioresorbable vascular scaffolds for percutaneous treatment of chronic total coronary occlusions: A one-year optical coherence tomography analysis from the GHOST-CTO registry.
    La Manna A; Miccichè E; D'Agosta G; Tensol Rodrigues Pereira G; Attizzani GF; Capranzano P; Capodanno D; Tamburino C
    Int J Cardiol; 2018 Feb; 253():45-49. PubMed ID: 29137819
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Bioresorbable vascular scaffolds in coronary chronic total occlusions revascularization: safety assessment related to struts coverage and apposition in 6-month OCT follow-up.
    Abellas-Sequeiros RA; Ocaranza-Sanchez R; Trillo-Nouche R; Gonzalez-Juanatey C; Gonzalez-Juanatey JR
    Heart Vessels; 2017 Sep; 32(9):1077-1084. PubMed ID: 28432385
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Incidence and imaging outcomes of acute scaffold disruption and late structural discontinuity after implantation of the absorb Everolimus-Eluting fully bioresorbable vascular scaffold: optical coherence tomography assessment in the ABSORB cohort B Trial (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions).
    Onuma Y; Serruys PW; Muramatsu T; Nakatani S; van Geuns RJ; de Bruyne B; Dudek D; Christiansen E; Smits PC; Chevalier B; McClean D; Koolen J; Windecker S; Whitbourn R; Meredith I; Garcia-Garcia HM; Veldhof S; Rapoza R; Ormiston JA
    JACC Cardiovasc Interv; 2014 Dec; 7(12):1400-11. PubMed ID: 25523532
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Vascular response to everolimus- and biolimus-eluting coronary stents versus everolimus-eluting bioresorbable scaffolds--an optical coherence tomography substudy of the EVERBIO II trial.
    Kallinikou Z; Arroyo D; Togni M; Lehman S; Corpataux N; Cook M; Müller O; Baeriswyl G; Stauffer JC; Goy JJ; Puricel SG; Cook S
    Swiss Med Wkly; 2016; 146():w14274. PubMed ID: 26766027
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Different vascular healing process between bioabsorbable polymer-coated everolimus-eluting stents versus bioresorbable vascular scaffolds via optical coherence tomography and coronary angioscopy (the ENHANCE study: ENdothelial Healing Assessment with Novel Coronary tEchnology).
    Wan Ahmad WA; Nakayoshi T; Mahmood Zuhdi AS; Ismail MD; Zainal Abidin I; Ino Y; Kubo T; Akasaka T; Fukumoto Y; Ueno T
    Heart Vessels; 2020 Apr; 35(4):463-473. PubMed ID: 31587103
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Head-to-head comparison of the neointimal response between metallic and bioresorbable everolimus-eluting scaffolds using optical coherence tomography.
    Gomez-Lara J; Brugaletta S; Farooq V; Onuma Y; Diletti R; Windecker S; Thuesen L; McClean D; Koolen J; Whitbourn R; Dudek D; Smits PC; Chevalier B; Regar E; Veldhof S; Rapoza R; Ormiston JA; Garcia-Garcia HM; Serruys PW
    JACC Cardiovasc Interv; 2011 Dec; 4(12):1271-80. PubMed ID: 22192368
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Real-World Bioresorbable Vascular Scaffold Experience Compared With Second-Generation Metallic Drug-Eluting Stents in Complex Coronary Lesions.
    Okamoto N; Ueda H; Yoshimura T; Chamaria S; Bhatheja S; Vengrenyuk Y; Rabiei S; Barrientos Y; Kapur V; Barman N; Sweeny J; Baber U; Mehran R; Sharma SK; Kini AS
    J Invasive Cardiol; 2018 Jul; 30(7):251-255. PubMed ID: 29656280
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Neointimal coverage and late apposition of everolimus-eluting bioresorbable scaffolds implanted in the acute phase of myocardial infarction: OCT data from the PRAGUE-19 study.
    Toušek P; Kočka V; Malý M; Lisa L; Buděšínský T; Widimský P
    Heart Vessels; 2016 Jun; 31(6):841-5. PubMed ID: 25896128
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Post-dilatation after implantation of bioresorbable everolimus- and novolimus-eluting scaffolds: an observational optical coherence tomography study of acute mechanical effects.
    Blachutzik F; Boeder N; Wiebe J; Mattesini A; Dörr O; Most A; Bauer T; Röther J; Tröbs M; Schlundt C; Achenbach S; Hamm CW; Nef HM
    Clin Res Cardiol; 2017 Apr; 106(4):271-279. PubMed ID: 27757522
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Angiographic and optical coherence tomography insights into bioresorbable scaffold thrombosis: single-center experience.
    Karanasos A; Van Mieghem N; van Ditzhuijzen N; Felix C; Daemen J; Autar A; Onuma Y; Kurata M; Diletti R; Valgimigli M; Kauer F; van Beusekom H; de Jaegere P; Zijlstra F; van Geuns RJ; Regar E
    Circ Cardiovasc Interv; 2015 May; 8(5):. PubMed ID: 25969547
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Early and late optical coherence tomography findings following everolimus-eluting bioresorbable vascular scaffold implantation in myocardial infarction: a preliminary report.
    Karanasos A; Muramatsu T; Diletti R; Nauta S; Onuma Y; Lenzen M; Nakatani S; Van Mieghem NM; Schultz C; De Jaegere PP; Serruys PW; Zijlstra F; Regar E; van Geuns RJ
    Hellenic J Cardiol; 2015; 56(2):125-35. PubMed ID: 25854441
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A comparative assessment by optical coherence tomography of the performance of the first and second generation of the everolimus-eluting bioresorbable vascular scaffolds.
    Gomez-Lara J; Brugaletta S; Diletti R; Garg S; Onuma Y; Gogas BD; van Geuns RJ; Dorange C; Veldhof S; Rapoza R; Whitbourn R; Windecker S; Garcia-Garcia HM; Regar E; Serruys PW
    Eur Heart J; 2011 Feb; 32(3):294-304. PubMed ID: 21123276
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Mid-term clinical outcomes of ABSORB bioresorbable vascular scaffold versus everolimus-eluting stent for coronary bifurcation lesions.
    Naganuma T; Kawamoto H; Panoulas VF; Latib A; Tanaka A; Mitomo S; Ruparelia N; Jabbour RJ; Chieffo A; Carlino M; Montorfano M; Colombo A
    Int J Cardiol; 2017 Nov; 246():26-31. PubMed ID: 28867010
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An observational study of clinical outcomes of everolimus-eluting bioresorbable scaffolds comparing the procedural use of optical coherence tomography against angiography alone.
    Hamshere S; Byrne A; Guttmann O; Rees P; Bourantas C; Weerakody R; Wragg A; Knight C; Mathur A; Jones DA
    Coron Artery Dis; 2018 Sep; 29(6):482-488. PubMed ID: 29642228
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Optical coherence tomography guidance for percutaneous coronary intervention with bioresorbable scaffolds.
    Caiazzo G; Longo G; Giavarini A; Kilic ID; Fabris E; Serdoz R; Mattesini A; Foin N; Secco GG; De Rosa S; Indolfi C; Di Mario C
    Int J Cardiol; 2016 Oct; 221():352-8. PubMed ID: 27404705
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of everolimus- and biolimus-eluting coronary stents with everolimus-eluting bioresorbable vascular scaffolds.
    Puricel S; Arroyo D; Corpataux N; Baeriswyl G; Lehmann S; Kallinikou Z; Muller O; Allard L; Stauffer JC; Togni M; Goy JJ; Cook S
    J Am Coll Cardiol; 2015 Mar; 65(8):791-801. PubMed ID: 25720622
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Clinical utility of optical coherence tomography (OCT) in the optimisation of Absorb bioresorbable vascular scaffold deployment during percutaneous coronary intervention.
    Allahwala UK; Cockburn JA; Shaw E; Figtree GA; Hansen PS; Bhindi R
    EuroIntervention; 2015 Feb; 10(10):1154-9. PubMed ID: 24647105
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.