BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

325 related articles for article (PubMed ID: 29516235)

  • 21. [Early effectiveness of arthroscopic three-point suture technique in treatment of anterior cruciate ligament tibial eminence avulsion fracture].
    Wang W; Fang K; Lin S; Wu G; Chen S
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2019 Jul; 33(7):860-864. PubMed ID: 31298004
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Clinical outcome of arthroscopic fixation of anterior tibial eminence avulsion fractures in skeletally mature patients: a comparison of suture and screw fixation technique.
    Pan RY; Yang JJ; Chang JH; Shen HC; Lin LC; Lian YT
    J Trauma Acute Care Surg; 2012 Feb; 72(2):E88-93. PubMed ID: 22328000
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Neglected ununited tibial eminence fractures in the skeletally immature: arthroscopic management.
    Abdelkafy A; Said HG
    Int Orthop; 2014 Dec; 38(12):2525-32. PubMed ID: 25069427
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Arthroscopic treatment of tibial eminence fractures using double-loop endobutton device: Surgical technique and short-term treatment outcomes.
    Yıldırım A; Aydın BK; Çiftci S; Güleç A
    Jt Dis Relat Surg; 2020; 31(3):456-462. PubMed ID: 32962575
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Effectiveness of mini incision and absorbable screw fixation for treatment of anterior cruciate ligament tibial eminence avulsion fracture].
    Sun H; Li Q; Tang X; Deng L; Zheng G; Wang F; Fu W; Li J
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2014 Sep; 28(9):1072-6. PubMed ID: 25509768
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Treatment of tibial eminence fractures with arthroscopic suture fixation technique: a retrospective study.
    Yuan Y; Huang X; Zhang Y; Wang Z
    Int J Clin Exp Med; 2015; 8(8):13797-803. PubMed ID: 26550328
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [A comparative study of absorbable screw fixation and absorbable screw combined with suture anchor fixation in treatment of avulsion fracture of posterior cruciate ligament at tibial insertion of knee joint].
    Wu S; Zhang K; Fu W; Li J
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2023 May; 37(5):572-577. PubMed ID: 37190834
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Arthroscopic fixation for tibial eminence fractures: A clinical retrospective study of cannulated screws versus transosseous anchor knot fixation techniques with suture anchors.
    Qu H; Meng Q; Sun Q; Du D; Zhang Q
    Knee; 2022 Mar; 35():105-113. PubMed ID: 35305496
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Arthroscopic fixation of avulsion fractures of the tibial eminence: technique and outcome.
    Hunter RE; Willis JA
    Arthroscopy; 2004 Feb; 20(2):113-21. PubMed ID: 14760342
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Therapeutic Effects of Small Incision Open Reduction and Internal Fixation and Arthroscopic High Strength Non-Absorbable Suture on Tibial Insertion Avulsion Fracture of the Anterior Cruciate Ligament.
    Wu J; Luo W; Ren F; Zheng H; Huang J
    Acta Chir Orthop Traumatol Cech; 2022; 89(1):53-59. PubMed ID: 35247245
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Comparison of open reduction hollow nail anchoring system with loop plate fixation under arthroscopy for the treatment of posterior cruciate ligament avulsion fractures].
    Wu R; Zhang ZF; Weng W; Yang HH; Min JK; Sun JW; Shen ZY
    Zhongguo Gu Shang; 2024 Jun; 37(6):5835-90. PubMed ID: 38910381
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Combining pullout suture and retrograde screw fixation for anterior cruciate ligament tibial eminence avulsion fractures: A case report.
    Hiranaka T; Furumatsu T; Tanaka T; Okazaki Y; Kodama Y; Kamatsuki Y; Masuda K; Seno N; Ozaki T
    J Orthop Surg (Hong Kong); 2020; 28(2):2309499020918681. PubMed ID: 32489139
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Clinical outcomes of acute displaced posterior cruciate ligament tibial avulsion fracture: A retrospective comparative study between the arthroscopic suture and EndoButton fixation techniques.
    Zhao D; Zhong J; Zhao B; Li Y; Shen D; Gui S; Hu W; Liu C; Qian D; Li J
    Orthop Traumatol Surg Res; 2021 Apr; 107(2):102798. PubMed ID: 33340707
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The most economical arthroscopic suture fixation for tibial intercondylar eminence avulsion fracture without any implant.
    Yuan L; Shi R; Chen Z; Ding W; Tan H
    J Orthop Surg Res; 2022 Jun; 17(1):327. PubMed ID: 35752828
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Arthroscopic Direct Anterior-to-Posterior Suture Suspension Fixation for the Treatment of Posterior Cruciate Ligament Tibial Avulsion Fracture.
    Tao T; Yang W; Tao X; Li Y; Zhang K; Jiang Y; Gui J
    Orthop Surg; 2022 Sep; 14(9):2031-2041. PubMed ID: 35894145
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Arthroscopic suture-fixation of anterior tibial intercondylar eminence fractures by retensioning of the ACL and hollowing of the tibial footprint: Objective and subjective clinical results in a paediatric population.
    Chalopin A; Geffroy L; Decante C; Noailles T; Hamel A
    Orthop Traumatol Surg Res; 2022 Oct; 108(6):103270. PubMed ID: 35288325
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Treatment of tibia avulsion fracture of posterior cruciate ligament with total arthroscopic internal fixation with adjustable double loop plate: A retrospective cohort study.
    Zhang F; Ye Y; Yu W; Yin D; Xu K
    Injury; 2022 Jun; 53(6):2233-2240. PubMed ID: 35437166
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Arthroscopic reduction and internal fixation (ARIF) versus open reduction internal fixation (ORIF) to elucidate the difference for tibial side PCL avulsion fixation: a randomized controlled trial (RCT).
    Sundararajan SR; Joseph JB; Ramakanth R; Jha AK; Rajasekaran S
    Knee Surg Sports Traumatol Arthrosc; 2021 Apr; 29(4):1251-1257. PubMed ID: 32712683
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Arthroscopic evaluation after surgical repair of intercondylar eminence fractures.
    Park HJ; Urabe K; Naruse K; Aikawa J; Fujita M; Itoman M
    Arch Orthop Trauma Surg; 2007 Nov; 127(9):753-7. PubMed ID: 17310373
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The degree of fracture reduction does not compromise the clinical efficacy of arthroscopic reduction and fixation of tibial posterior cruciate ligament avulsion fractures: A retrospective study.
    Zhou Z; Wang S; Xiao J; Mao Y; Li L; Xu W; She C
    Medicine (Baltimore); 2023 Sep; 102(39):e35356. PubMed ID: 37773785
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 17.