BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

961 related articles for article (PubMed ID: 29519754)

  • 1. Aortic valve and left ventricular outflow tract calcium volume and distribution in transcatheter aortic valve replacement: Influence on the risk of significant paravalvular regurgitation.
    Hansson NC; Leipsic J; Pugliese F; Andersen HR; Rossi A; Simonato M; Jensen KT; Christiansen EH; Terkelsen CJ; Blanke P; Tang M; Krusell LR; Klaaborg KE; Terp K; Kennon S; Dvir D; Bøtker HE; Webb J; Nørgaard BL
    J Cardiovasc Comput Tomogr; 2018; 12(4):290-297. PubMed ID: 29519754
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Practical determination of aortic valve calcium volume score on contrast-enhanced computed tomography prior to transcatheter aortic valve replacement and impact on paravalvular regurgitation: Elucidating optimal threshold cutoffs.
    Bettinger N; Khalique OK; Krepp JM; Hamid NB; Bae DJ; Pulerwitz TC; Liao M; Hahn RT; Vahl TP; Nazif TM; George I; Leon MB; Einstein AJ; Kodali SK
    J Cardiovasc Comput Tomogr; 2017; 11(4):302-308. PubMed ID: 28457950
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Computed Tomography-Based Oversizing Degrees and Incidence of Paravalvular Regurgitation of a New Generation Transcatheter Heart Valve.
    Blanke P; Pibarot P; Hahn R; Weissman N; Kodali S; Thourani V; Parvataneni R; Dvir D; Naoum C; Nørgaard BL; Douglas P; Jaber W; Khalique OK; Jilaihawi H; Mack M; Smith C; Leon M; Webb J; Leipsic J
    JACC Cardiovasc Interv; 2017 Apr; 10(8):810-820. PubMed ID: 28427598
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Quantity and location of aortic valve complex calcification predicts severity and location of paravalvular regurgitation and frequency of post-dilation after balloon-expandable transcatheter aortic valve replacement.
    Khalique OK; Hahn RT; Gada H; Nazif TM; Vahl TP; George I; Kalesan B; Forster M; Williams MB; Leon MB; Einstein AJ; Pulerwitz TC; Pearson GD; Kodali SK
    JACC Cardiovasc Interv; 2014 Aug; 7(8):885-94. PubMed ID: 25147034
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Predictors for Paravalvular Regurgitation After TAVR With the Self-Expanding Prosthesis: Quantitative Measurement of MDCT Analysis.
    Yoon SH; Ahn JM; Ohno Y; Barbanti M; Chan J; Lin MS; Kim YH; Yang DH; Sugiyama D; Chan KT; Immé S; Tamburino CI; Sgroi C; Park DW; Kang SJ; Lee SW; Lee CW; Park SW; Lee M; Kao HL; Tamburino C; Park SJ
    JACC Cardiovasc Imaging; 2016 Oct; 9(10):1233-1234. PubMed ID: 26777220
    [No Abstract]   [Full Text] [Related]  

  • 6. Incidence and severity of paravalvular aortic regurgitation with multidetector computed tomography nominal area oversizing or undersizing after transcatheter heart valve replacement with the Sapien 3: a comparison with the Sapien XT.
    Yang TH; Webb JG; Blanke P; Dvir D; Hansson NC; Nørgaard BL; Thompson CR; Thomas M; Wendler O; Vahanian A; Himbert D; Kodali SK; Hahn RT; Thourani VH; Schymik G; Precious B; Berger A; Wood DA; Pibarot P; Rodés-Cabau J; Jaber WA; Leon MB; Walther T; Leipsic J
    JACC Cardiovasc Interv; 2015 Mar; 8(3):462-471. PubMed ID: 25790764
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Predictive value for paravalvular regurgitation of 3-dimensional anatomic aortic annulus shape assessed by multidetector computed tomography post-transcatheter aortic valve replacement.
    Ciobotaru V; Maupas E; Dürrleman N; Boulenc JM; Borton A; Pujadas-Berthault P; Rioux P; Maubon A
    Eur Heart J Cardiovasc Imaging; 2016 Jan; 17(1):85-95. PubMed ID: 26003147
    [TBL] [Abstract][Full Text] [Related]  

  • 8. 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis.
    Willson AB; Webb JG; Labounty TM; Achenbach S; Moss R; Wheeler M; Thompson C; Min JK; Gurvitch R; Norgaard BL; Hague CJ; Toggweiler S; Binder R; Freeman M; Poulter R; Poulsen S; Wood DA; Leipsic J
    J Am Coll Cardiol; 2012 Apr; 59(14):1287-94. PubMed ID: 22365423
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Multidetector CT predictors of prosthesis-patient mismatch in transcatheter aortic valve replacement.
    Freeman M; Webb JG; Willson AB; Wheeler M; Blanke P; Moss RR; Thompson CR; Munt B; Norgaard BL; Yang TH; Min JK; Poulsen S; Hansson NC; Binder RK; Toggweiler S; Hague C; Wood DA; Pibarot P; Leipsic J
    J Cardiovasc Comput Tomogr; 2013; 7(4):248-55. PubMed ID: 24148778
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Three-dimensional multidetector computed tomography versus conventional 2-dimensional transesophageal echocardiography for annular sizing in transcatheter aortic valve replacement: Influence on postprocedural paravalvular aortic regurgitation.
    Hansson NC; Thuesen L; Hjortdal VE; Leipsic J; Andersen HR; Poulsen SH; Webb JG; Christiansen EH; Rasmussen LE; Krusell LR; Terp K; Klaaborg KE; Tang M; Lassen JF; Bøtker HE; Nørgaard BL
    Catheter Cardiovasc Interv; 2013 Nov; 82(6):977-86. PubMed ID: 23703899
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The impact of calcium volume and distribution in aortic root injury related to balloon-expandable transcatheter aortic valve replacement.
    Hansson NC; Nørgaard BL; Barbanti M; Nielsen NE; Yang TH; Tamburino C; Dvir D; Jilaihawi H; Blanke P; Makkar RR; Latib A; Colombo A; Tarantini G; Raju R; Wood D; Andersen HR; Ribeiro HB; Kapadia S; Min J; Feuchtner G; Gurvitch R; Alqoofi F; Pelletier M; Ussia GP; Napodano M; Sandoli de Brito F; Kodali S; Pache G; Canovas SJ; Berger A; Murphy D; Svensson LG; Rodés-Cabau J; Leon MB; Webb JG; Leipsic J
    J Cardiovasc Comput Tomogr; 2015; 9(5):382-92. PubMed ID: 26164109
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Risk factors for paravalvular leak after transcatheter aortic valve replacement.
    Pollari F; Dell'Aquila AM; Söhn C; Marianowicz J; Wiehofsky P; Schwab J; Pauschinger M; Hitzl W; Fischlein T; Pfeiffer S
    J Thorac Cardiovasc Surg; 2019 Apr; 157(4):1406-1415.e3. PubMed ID: 30482527
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of self-expanding and balloon-expandable transcatheter aortic valves morphology and association with paravalvular regurgitation: Evaluation using multidetector computed tomography.
    Almeida JG; Ferreira SM; Fonseca P; Dias T; Guerreiro C; Barbosa A; Teixeira P; Carvalho M; Ferreira W; Ferreira ND; Braga P; Ribeiro J; Ribeiro VG
    Catheter Cardiovasc Interv; 2018 Sep; 92(3):533-541. PubMed ID: 29105953
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Predictors of Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation for Aortic Stenosis Using New-Generation Balloon-Expandable SAPIEN 3.
    Kaneko H; Hoelschermann F; Tambor G; Yoon SH; Neuss M; Butter C
    Am J Cardiol; 2017 Feb; 119(4):618-622. PubMed ID: 28010874
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Computed tomography predictors of mortality, stroke and conduction disturbances in women undergoing TAVR: A sub-analysis of the WIN-TAVI registry.
    Spaziano M; Chieffo A; Watanabe Y; Chandrasekhar J; Sartori S; Lefèvre T; Petronio AS; Presbitero P; Tchetche D; Iadanza A; Van Mieghem NM; Mehilli J; Mehran R; Morice MC;
    J Cardiovasc Comput Tomogr; 2018; 12(4):338-343. PubMed ID: 29735255
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Prosthesis-Specific Predictors of Paravalvular Regurgitation after Transcatheter Aortic Valve Replacement: Impact of Calcification and Sizing on Balloon-Expandable versus Self-Expandable Transcatheter Heart Valves.
    Stähli BE; Nguyen-Kim TD; Gebhard C; Erhart L; Frauenfelder T; Tanner FC; Falk V; Landmesser U; Nietlispach F; Lüscher TF; Maier W; Binder RK
    J Heart Valve Dis; 2015 Jan; 24(1):10-21. PubMed ID: 26182615
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Impact of Annular Oversizing on Paravalvular Regurgitation and Valve Hemodynamics: New Insights From PARTNER 3.
    Ihdayhid AR; Leipsic J; Hahn RT; Pibarot P; Thourani V; Makkar R; Kodali S; Russo M; Kapadia S; Chen Y; Mack M; Webb J; Bax J; Leon MB; Blanke P
    JACC Cardiovasc Interv; 2021 Oct; 14(19):2158-2169. PubMed ID: 34620395
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The aortic valve calcium nodule score (AVCNS) independently predicts paravalvular regurgitation after transcatheter aortic valve replacement (TAVR).
    Azzalini L; Ghoshhajra BB; Elmariah S; Passeri JJ; Inglessis I; Palacios IF; Abbara S
    J Cardiovasc Comput Tomogr; 2014; 8(2):131-40. PubMed ID: 24661826
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Impact of device-host interaction on paravalvular aortic regurgitation with different transcatheter heart valves.
    Rodríguez-Olivares R; El Faquir N; Rahhab Z; van Gils L; Ren B; Sakhi R; Geleijnse ML; van Domburg R; de Jaegere PPT; Zamorano Gómez JL; Van Mieghem NM
    Cardiovasc Revasc Med; 2019 Feb; 20(2):126-132. PubMed ID: 29779973
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Relationship of Annular Sizing Using Multidetector Computed Tomographic Imaging and Clinical Outcomes After Self-Expanding CoreValve Transcatheter Aortic Valve Replacement.
    Popma JJ; Gleason TG; Yakubov SJ; Harrison JK; Forrest JK; Maini B; Ruiz CE; Pinto DS; Costa M; Resar J; Conte J; Crestanello J; Chang Y; Oh JK; Reardon MJ; Adams DH
    Circ Cardiovasc Interv; 2016 Jul; 9(7):. PubMed ID: 27369803
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 49.