575 related articles for article (PubMed ID: 29521461)
1. Wear and Corrosion Interactions at the Titanium/Zirconia Interface: Dental Implant Application.
Sikora CL; Alfaro MF; Yuan JC; Barao VA; Sukotjo C; Mathew MT
J Prosthodont; 2018 Dec; 27(9):842-852. PubMed ID: 29521461
[TBL] [Abstract][Full Text] [Related]
2. Synergistic interactions between corrosion and wear at titanium-based dental implant connections: A scoping review.
Apaza-Bedoya K; Tarce M; Benfatti CAM; Henriques B; Mathew MT; Teughels W; Souza JCM
J Periodontal Res; 2017 Dec; 52(6):946-954. PubMed ID: 28612506
[TBL] [Abstract][Full Text] [Related]
3. Wear at the titanium-titanium and the titanium-zirconia implant-abutment interface: a comparative in vitro study.
Stimmelmayr M; Edelhoff D; Güth JF; Erdelt K; Happe A; Beuer F
Dent Mater; 2012 Dec; 28(12):1215-20. PubMed ID: 23021964
[TBL] [Abstract][Full Text] [Related]
4. Fracture strength study of internally connected zirconia abutments reinforced with titanium inserts.
Chun HJ; Yeo IS; Lee JH; Kim SK; Heo SJ; Koak JY; Han JS; Lee SJ
Int J Oral Maxillofac Implants; 2015; 30(2):346-50. PubMed ID: 25830395
[TBL] [Abstract][Full Text] [Related]
5. Load fatigue performance of conical implant-abutment connections.
Seetoh YL; Tan KB; Chua EK; Quek HC; Nicholls JI
Int J Oral Maxillofac Implants; 2011; 26(4):797-806. PubMed ID: 21841990
[TBL] [Abstract][Full Text] [Related]
6. Wear at the Implant-Abutment Interface of Zirconia Abutments Manufactured by Three CAD/CAM Systems.
Pinheiro Tannure AL; Cunha AG; Borges Junior LA; da Silva Concílio LR; Claro Neves AC
Int J Oral Maxillofac Implants; 2017; 32(6):1241-1250. PubMed ID: 29140369
[TBL] [Abstract][Full Text] [Related]
7. Reduction of Tribocorrosion Products When Using the Platform-Switching Concept.
Alrabeah GO; Knowles JC; Petridis H
J Dent Res; 2018 Aug; 97(9):995-1002. PubMed ID: 29578825
[TBL] [Abstract][Full Text] [Related]
8. In vitro assessment of three types of zirconia implant abutments under static load.
Kim JS; Raigrodski AJ; Flinn BD; Rubenstein JE; Chung KH; Mancl LA
J Prosthet Dent; 2013 Apr; 109(4):255-63. PubMed ID: 23566607
[TBL] [Abstract][Full Text] [Related]
9. A pilot study of joint stability at the zirconium or titanium abutment/titanium implant interface.
Cavusoglu Y; Akça K; Gürbüz R; Cehreli MC
Int J Oral Maxillofac Implants; 2014; 29(2):338-43. PubMed ID: 24683559
[TBL] [Abstract][Full Text] [Related]
10. The behavior of a zirconia or metal abutment on the implant-abutment interface during cyclic loading.
Queiroz DA; Hagee N; Lee DJ; Zheng F
J Prosthet Dent; 2020 Aug; 124(2):211-216. PubMed ID: 31810616
[TBL] [Abstract][Full Text] [Related]
11. Fracture resistance of crowns cemented on titanium and zirconia implant abutments: a comparison of monolithic versus manually veneered all-ceramic systems.
Martínez-Rus F; Ferreiroa A; Özcan M; Bartolomé JF; Pradíes G
Int J Oral Maxillofac Implants; 2012; 27(6):1448-55. PubMed ID: 23189296
[TBL] [Abstract][Full Text] [Related]
12. Effect of fatigue loading on the fracture strength and failure mode of lithium disilicate and zirconia implant abutments.
Elsayed A; Wille S; Al-Akhali M; Kern M
Clin Oral Implants Res; 2018 Jan; 29(1):20-27. PubMed ID: 28664585
[TBL] [Abstract][Full Text] [Related]
13. Wear at the titanium-zirconia implant-abutment interface: a pilot study.
Klotz MW; Taylor TD; Goldberg AJ
Int J Oral Maxillofac Implants; 2011; 26(5):970-5. PubMed ID: 22010078
[TBL] [Abstract][Full Text] [Related]
14. The effect of zirconia or titanium as abutment material on soft peri-implant tissues: a systematic review and meta-analysis.
Linkevicius T; Vaitelis J
Clin Oral Implants Res; 2015 Sep; 26 Suppl 11():139-47. PubMed ID: 26073346
[TBL] [Abstract][Full Text] [Related]
15. Mechanical stability of angulated zirconia abutments supporting maxillary anterior single crowns on narrow-diameter implants.
Ma R; Yu P; Zhang Y; Xie C; Tan X; Sun J; Yu H
Clin Oral Investig; 2023 Jan; 27(1):221-233. PubMed ID: 36161530
[TBL] [Abstract][Full Text] [Related]
16. Fretting corrosion behaviour of Ti-6Al-4V reinforced with zirconia in foetal bovine serum.
Semetse L; Obadele BA; Raganya L; Geringer J; Olubambi PA
J Mech Behav Biomed Mater; 2019 Dec; 100():103392. PubMed ID: 31430704
[TBL] [Abstract][Full Text] [Related]
17. Load to failure of different zirconia implant abutments with titanium components.
Mascarenhas F; Yilmaz B; McGlumphy E; Clelland N; Seidt J
J Prosthet Dent; 2017 Jun; 117(6):749-754. PubMed ID: 27836140
[TBL] [Abstract][Full Text] [Related]
18. Differences in micromorphology of the implant-abutment junction for original and third-party abutments on a representative dental implant.
Fokas G; Ma L; Chronopoulos V; Janda M; Mattheos N
J Prosthet Dent; 2019 Jan; 121(1):143-150. PubMed ID: 30006227
[TBL] [Abstract][Full Text] [Related]
19. Load to failure of different zirconia abutments for an internal hexagon implant.
Yilmaz B; Salaita LG; Seidt JD; McGlumphy EA; Clelland NL
J Prosthet Dent; 2015 Sep; 114(3):373-7. PubMed ID: 25976709
[TBL] [Abstract][Full Text] [Related]
20. Assessment of reliability of CAD-CAM tooth-colored implant custom abutments.
Guilherme NM; Chung KH; Flinn BD; Zheng C; Raigrodski AJ
J Prosthet Dent; 2016 Aug; 116(2):206-13. PubMed ID: 26948082
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]