BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

866 related articles for article (PubMed ID: 29527740)

  • 21. Effect of Different Implant-Abutment Connection Materials on the Fracture Resistance of Zirconia Abutments.
    AlAmar M; Alqahtani F
    J Oral Implantol; 2020 Apr; 46(2):88-92. PubMed ID: 31909678
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Fracture resistance of crowns cemented on titanium and zirconia implant abutments: a comparison of monolithic versus manually veneered all-ceramic systems.
    Martínez-Rus F; Ferreiroa A; Özcan M; Bartolomé JF; Pradíes G
    Int J Oral Maxillofac Implants; 2012; 27(6):1448-55. PubMed ID: 23189296
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Retentive strength of two-piece CAD/CAM zirconia implant abutments.
    Gehrke P; Alius J; Fischer C; Erdelt KJ; Beuer F
    Clin Implant Dent Relat Res; 2014 Dec; 16(6):920-5. PubMed ID: 23527950
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Wear at the titanium-titanium and the titanium-zirconia implant-abutment interface: a comparative in vitro study.
    Stimmelmayr M; Edelhoff D; Güth JF; Erdelt K; Happe A; Beuer F
    Dent Mater; 2012 Dec; 28(12):1215-20. PubMed ID: 23021964
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Mechanical stability of fully personalized, abutment-free zirconia implant crowns on a novel implant-crown interface.
    Hjerppe J; Jung RE; Hämmerle CH; Özcan M; Mühlemann S
    J Dent; 2022 Jun; 121():104121. PubMed ID: 35395344
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Fracture Resistance and Mode of Failure of Ceramic versus Titanium Implant Abutments and Single Implant-Supported Restorations.
    Sghaireen MG
    Clin Implant Dent Relat Res; 2015 Jun; 17(3):554-61. PubMed ID: 24118925
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Fatigue resistance and fracture strength of narrow-diameter one-piece zirconia implants with angled abutments.
    Atalay P; Öztaş DD
    J Esthet Restor Dent; 2022 Oct; 34(7):1060-1067. PubMed ID: 35855644
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Effect of fatigue loading on the fracture strength and failure mode of lithium disilicate and zirconia implant abutments.
    Elsayed A; Wille S; Al-Akhali M; Kern M
    Clin Oral Implants Res; 2018 Jan; 29(1):20-27. PubMed ID: 28664585
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Load fatigue performance of conical implant-abutment connections.
    Seetoh YL; Tan KB; Chua EK; Quek HC; Nicholls JI
    Int J Oral Maxillofac Implants; 2011; 26(4):797-806. PubMed ID: 21841990
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Experimental research on the relationship between fit accuracy and fracture resistance of zirconia abutments.
    Sui X; Wei H; Wang D; Han Y; Deng J; Wang Y; Wang J; Yang J
    J Dent; 2014 Oct; 42(10):1353-9. PubMed ID: 24561040
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effect of platform connection and abutment material on stress distribution in single anterior implant-supported restorations: a nonlinear 3-dimensional finite element analysis.
    Carvalho MA; Sotto-Maior BS; Del Bel Cury AA; Pessanha Henriques GE
    J Prosthet Dent; 2014 Nov; 112(5):1096-102. PubMed ID: 24831744
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Fatigue and Stress Distribution Analyses of Ceramic-Reinforced PEEK Abutments Restored with Monolithic Zirconia Crowns as an Alternative to Conventional Esthetic Abutments.
    Akan E; Velioğlu E; Çömlekoğlu ME; Çömlekoğlu MD
    Int J Oral Maxillofac Implants; 2022; 37(3):533-542. PubMed ID: 35727245
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Evaluation of the sealing capability of implants to titanium and zirconia abutments against Porphyromonas gingivalis, Prevotella intermedia, and Fusobacterium nucleatum under different screw torque values.
    Smith NA; Turkyilmaz I
    J Prosthet Dent; 2014 Sep; 112(3):561-7. PubMed ID: 24656409
    [TBL] [Abstract][Full Text] [Related]  

  • 34. In vitro fatigue and fracture strength testing of one-piece zirconia implant abutments and zirconia implant abutments connected to titanium cores.
    Stimmelmayr M; Sagerer S; Erdelt K; Beuer F
    Int J Oral Maxillofac Implants; 2013; 28(2):488-93. PubMed ID: 23527351
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Fracture resistance and failure location of zirconium and metallic implant abutments.
    Aramouni P; Zebouni E; Tashkandi E; Dib S; Salameh Z; Almas K
    J Contemp Dent Pract; 2008 Nov; 9(7):41-8. PubMed ID: 18997915
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of fit accuracy and torque maintenance of zirconia and titanium abutments for internal tri-channel and external-hex implant connections.
    Siadat H; Beyabanaki E; Mousavi N; Alikhasi M
    J Adv Prosthodont; 2017 Aug; 9(4):271-277. PubMed ID: 28874994
    [TBL] [Abstract][Full Text] [Related]  

  • 37. One-piece internal zirconia abutments for single-tooth restorations on narrow and regular diameter implants: A 5-year prospective follow-up study.
    Nilsson A; Johansson LÅ; Lindh C; Ekfeldt A
    Clin Implant Dent Relat Res; 2017 Oct; 19(5):916-925. PubMed ID: 28791801
    [TBL] [Abstract][Full Text] [Related]  

  • 38. In vitro performance of one- and two-piece zirconia implant systems for anterior application.
    Kammermeier A; Rosentritt M; Behr M; Schneider-Feyrer S; Preis V
    J Dent; 2016 Oct; 53():94-101. PubMed ID: 27528418
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Influence of loading and aging on the fracture strength of an injection-molded two-piece zirconia implant restored with a zirconia abutment.
    Kohal RJ; von Schierholz C; Nold J; Spies BC; Adolfsson E; Vach K; Burkhardt F
    Clin Oral Implants Res; 2023 Feb; 34(2):105-115. PubMed ID: 36444693
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Screw stability of CAD-CAM titanium and zirconia abutments on different implants: An in vitro study.
    Yilmaz B; Çakmak G; Batak B; Johnston WM
    Clin Implant Dent Relat Res; 2021 Jun; 23(3):373-379. PubMed ID: 33938119
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 44.