These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 29529960)

  • 1. Hemodialysis Reliable Outflow graft radiopaque tip detachment and embolization during implantation.
    Wagner MA; Dillavou ED
    J Vasc Access; 2018 May; 19(3):330-331. PubMed ID: 29529960
    [No Abstract]   [Full Text] [Related]  

  • 2. Early infection risk with primary versus staged Hemodialysis Reliable Outflow (HeRO) graft implantation.
    Griffin AS; Gage SM; Lawson JH; Kim CY
    J Vasc Surg; 2017 Jan; 65(1):136-141. PubMed ID: 27687322
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Percutaneous retrieval of a fractured HeRO graft venous outflow component with endobronchial forceps.
    Patel N; Hussain J; Gemmete JJ; Chick JFB; Woodside K; Srinivasa RN
    J Vasc Access; 2019 May; 20(3):339-341. PubMed ID: 30461342
    [No Abstract]   [Full Text] [Related]  

  • 4. Embolization of Onyx Causing Acute Limb Ischemia.
    Lind BB; Briggs CS; Golan J; Gupta N
    Ann Vasc Surg; 2017 Jan; 38():320.e5-320.e8. PubMed ID: 27554697
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Vascular access via translumbar Hemodialysis Reliable Outflow dialysis catheter in a case of severe central venous occlusion.
    Loskutov A; Dave A; Gooden C; Saucier NA; Cho KH; Wible BC; Borsa JJ
    J Vasc Access; 2018 Jul; 19(4):410-411. PubMed ID: 29582678
    [No Abstract]   [Full Text] [Related]  

  • 6. Cost analysis of the Hemodialysis Reliable Outflow (HeRO) Graft compared to the tunneled dialysis catheter.
    Al Shakarchi J; Inston N; Jones RG; Maclaine G; Hollinworth D
    J Vasc Surg; 2016 Apr; 63(4):1026-33. PubMed ID: 26826055
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Embolism after inferior vena cava filter mesh fragmentation.
    Buckley O; DeVore A; Ersoy H; Sobieszczyk P; Auger WR; Kwong R; Rybicki FJ; Goldhaber SZ
    J Vasc Interv Radiol; 2010 Nov; 21(11):1782-4. PubMed ID: 20884230
    [No Abstract]   [Full Text] [Related]  

  • 8. Superior Mesenteric Artery Stent-Graft Migration into the Duodenum.
    Tokunaga K; Furuta A; Yoshimura M; Togashi K
    J Vasc Interv Radiol; 2019 Oct; 30(10):1614. PubMed ID: 31547927
    [No Abstract]   [Full Text] [Related]  

  • 9. Recurrent hemoptysis: a predictor of poor outcome in hemodialysis catheter embolization.
    Nwiloh JO; Fariyike TT
    J Vasc Access; 2011; 12(3):266. PubMed ID: 21104670
    [No Abstract]   [Full Text] [Related]  

  • 10. Fracture and embolization of a temporary hemodialysis femoral catheter.
    Helal I; Elyounsi F; Hamida FB; Aderrahim E; Hedri H; Maiz HB; Abdallah TB; Kheder A
    J Vasc Access; 2010; 11(1):74-5. PubMed ID: 20119916
    [No Abstract]   [Full Text] [Related]  

  • 11. Obesity Increases the Risk of Primary Nonfunction and Early Access Loss, and Decreases Overall Patency in Patients Who Underwent Hemodialysis Reliable Outflow Device Placement.
    Naffouje SA; Tzvetanov I; Bui JT; Gaba R; Bernardo K; Jeon H
    Ann Vasc Surg; 2016 Oct; 36():236-243. PubMed ID: 27421202
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Complications of endovascular aortic repair: prevention and management.
    Farber MA
    Tex Heart Inst J; 2009; 36(5):444-5. PubMed ID: 19876424
    [No Abstract]   [Full Text] [Related]  

  • 13. Paradoxical embolus following percutaneous thrombectomy of hemodialysis reliable outflow graft.
    Gilmore B; Benrashid E; Youngwirth LM; Lawson JH
    J Vasc Access; 2015; 16(6):533-6. PubMed ID: 26515536
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Spontaneous fracture and embolization of pacemaker leads.
    Mollazadeh R; Sattarzadeh R; Sefidbakht S
    Europace; 2015 Dec; 17(12):1815. PubMed ID: 26462706
    [No Abstract]   [Full Text] [Related]  

  • 15. Minimally invasive axillary to right atrial graft for hemodialysis access utilizing the intraluminal flow guard graft.
    Goldstein LJ; Balabanoff C; Carillo R; de Mendoza VL; Bornak A; Tabbara M
    J Vasc Access; 2015 Sep; 16(5):e87-8. PubMed ID: 26349871
    [No Abstract]   [Full Text] [Related]  

  • 16. Fenestrated stent-graft repair: which stent should be used to secure target vessel fenestrations?
    Scurr JR; How TV; McWilliams RG; Lane S; Gilling-Smith GL
    J Endovasc Ther; 2008 Jun; 15(3):344-8. PubMed ID: 18540704
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Regarding "Failure modes of thoracic endografts: prevention and management".
    Timaran CH; Dake MD
    J Vasc Surg; 2009 Sep; 50(3):705; author reply 705. PubMed ID: 19700104
    [No Abstract]   [Full Text] [Related]  

  • 18. Invited commentary on: separation of components in fenestrated and branched endovascular grafting--branch protection or a potentially new mode of failure?
    Verhoeven EL
    Eur J Vasc Endovasc Surg; 2008 Jul; 36(1):10. PubMed ID: 18400528
    [No Abstract]   [Full Text] [Related]  

  • 19. Endovascular treatment of renal artery occlusion caused by aortic stentgraft migration.
    Stanišić MG; Majewska N; Romanowski M; Kulesza J; Juszkat R; Makałowski M; Majewski W
    Pol Przegl Chir; 2015 Apr; 87(4):181-4. PubMed ID: 26146117
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Nellix stent graft migration after endovascular aneurysm sealing.
    Antoniou GA; Bashaeb K; Ibrahim R
    Vasa; 2016 Nov; 45(6):505-507. PubMed ID: 27598051
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.