358 related articles for article (PubMed ID: 29530821)
1. Zinc-based alloys for degradable vascular stent applications.
Mostaed E; Sikora-Jasinska M; Drelich JW; Vedani M
Acta Biomater; 2018 Apr; 71():1-23. PubMed ID: 29530821
[TBL] [Abstract][Full Text] [Related]
2. Current status and perspectives of zinc-based absorbable alloys for biomedical applications.
Hernández-Escobar D; Champagne S; Yilmazer H; Dikici B; Boehlert CJ; Hermawan H
Acta Biomater; 2019 Oct; 97():1-22. PubMed ID: 31351253
[TBL] [Abstract][Full Text] [Related]
3. The enhancement of mechanical properties and uniform degradation of electrodeposited Fe-Zn alloys by multilayered design for biodegradable stent applications.
Xu Y; Wang W; Yu F; Yang S; Yuan Y; Wang Y
Acta Biomater; 2023 Apr; 161():309-323. PubMed ID: 36858165
[TBL] [Abstract][Full Text] [Related]
4. Towards revealing key factors in mechanical instability of bioabsorbable Zn-based alloys for intended vascular stenting.
Mostaed E; Sikora-Jasinska M; Ardakani MS; Mostaed A; Reaney IM; Goldman J; Drelich JW
Acta Biomater; 2020 Mar; 105():319-335. PubMed ID: 31982587
[TBL] [Abstract][Full Text] [Related]
5. Novel Zn-based alloys for biodegradable stent applications: Design, development and in vitro degradation.
Mostaed E; Sikora-Jasinska M; Mostaed A; Loffredo S; Demir AG; Previtali B; Mantovani D; Beanland R; Vedani M
J Mech Behav Biomed Mater; 2016 Jul; 60():581-602. PubMed ID: 27062241
[TBL] [Abstract][Full Text] [Related]
6. Biodegradable Metals for Cardiovascular Stents: from Clinical Concerns to Recent Zn-Alloys.
Bowen PK; Shearier ER; Zhao S; Guillory RJ; Zhao F; Goldman J; Drelich JW
Adv Healthc Mater; 2016 May; 5(10):1121-40. PubMed ID: 27094868
[TBL] [Abstract][Full Text] [Related]
7. Microstructure, mechanical properties, biocompatibility, and in vitro corrosion and degradation behavior of a new Zn-5Ge alloy for biodegradable implant materials.
Tong X; Zhang D; Zhang X; Su Y; Shi Z; Wang K; Lin J; Li Y; Lin J; Wen C
Acta Biomater; 2018 Dec; 82():197-204. PubMed ID: 30316837
[TBL] [Abstract][Full Text] [Related]
8. Experimental study on novel biodegradable Zn-Fe-Si alloys.
Zeng Y; Guan Z; Linsley CS; Pan S; Liu J; Wu BM; Li X
J Biomed Mater Res B Appl Biomater; 2022 Oct; 110(10):2266-2275. PubMed ID: 35522226
[TBL] [Abstract][Full Text] [Related]
9. Effect of strain on degradation behaviors of WE43, Fe and Zn wires.
Chen K; Lu Y; Tang H; Gao Y; Zhao F; Gu X; Fan Y
Acta Biomater; 2020 Sep; 113():627-645. PubMed ID: 32574860
[TBL] [Abstract][Full Text] [Related]
10. Improved biocompatibility of Zn-Ag-based stent materials by microstructure refinement.
Guillory RJ; Mostaed E; Oliver AA; Morath LM; Earley EJ; Flom KL; Kolesar TM; Mostaed A; Summers HD; Kwesiga MP; Drelich JW; Carlson KD; Dragomir-Daescu D; Goldman J
Acta Biomater; 2022 Jun; 145():416-426. PubMed ID: 35367631
[TBL] [Abstract][Full Text] [Related]
11. Impact of gadolinium on mechanical properties, corrosion resistance, and biocompatibility of Zn-1Mg-xGd alloys for biodegradable bone-implant applications.
Tong X; Zhu L; Wang K; Shi Z; Huang S; Li Y; Ma J; Wen C; Lin J
Acta Biomater; 2022 Apr; 142():361-373. PubMed ID: 35189378
[TBL] [Abstract][Full Text] [Related]
12. Fabrication, mechanical properties and in vitro degradation behavior of newly developed ZnAg alloys for degradable implant applications.
Sikora-Jasinska M; Mostaed E; Mostaed A; Beanland R; Mantovani D; Vedani M
Mater Sci Eng C Mater Biol Appl; 2017 Aug; 77():1170-1181. PubMed ID: 28531993
[TBL] [Abstract][Full Text] [Related]
13. Hemocompatibility of biodegradable Zn-0.8 wt% (Cu, Mn, Li) alloys.
Yin YX; Zhou C; Shi YP; Shi ZZ; Lu TH; Hao Y; Liu CH; Wang X; Zhang HJ; Wang LN
Mater Sci Eng C Mater Biol Appl; 2019 Nov; 104():109896. PubMed ID: 31499977
[TBL] [Abstract][Full Text] [Related]
14. Fabrication and characterization of biodegradable Zn-Cu-Mn alloy micro-tubes and vascular stents: Microstructure, texture, mechanical properties and corrosion behavior.
Jiang J; Huang H; Niu J; Zhu D; Yuan G
Acta Biomater; 2022 Oct; 151():647-660. PubMed ID: 35917908
[TBL] [Abstract][Full Text] [Related]
15. Preparation of medical Mg-Zn alloys and the effect of different zinc contents on the alloy.
Hu Y; Guo X; Qiao Y; Wang X; Lin Q
J Mater Sci Mater Med; 2022 Jan; 33(1):9. PubMed ID: 34982233
[TBL] [Abstract][Full Text] [Related]
16. Degradable magnesium-based alloys for biomedical applications: The role of critical alloying elements.
Chen Y; Dou J; Yu H; Chen C
J Biomater Appl; 2019 May; 33(10):1348-1372. PubMed ID: 30854910
[TBL] [Abstract][Full Text] [Related]
17. Evaluation of biodegradable Zn-1%Mg and Zn-1%Mg-0.5%Ca alloys for biomedical applications.
Katarivas Levy G; Leon A; Kafri A; Ventura Y; Drelich JW; Goldman J; Vago R; Aghion E
J Mater Sci Mater Med; 2017 Sep; 28(11):174. PubMed ID: 28956207
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of wrought Zn-Al alloys (1, 3, and 5 wt % Al) through mechanical and in vivo testing for stent applications.
Bowen PK; Seitz JM; Guillory RJ; Braykovich JP; Zhao S; Goldman J; Drelich JW
J Biomed Mater Res B Appl Biomater; 2018 Jan; 106(1):245-258. PubMed ID: 28130871
[TBL] [Abstract][Full Text] [Related]
19. Prospects and strategies for magnesium alloys as biodegradable implants from crystalline to bulk metallic glasses and composites-A review.
Kiani F; Wen C; Li Y
Acta Biomater; 2020 Feb; 103():1-23. PubMed ID: 31881312
[TBL] [Abstract][Full Text] [Related]
20. Study on the Mg-Li-Zn ternary alloy system with improved mechanical properties, good degradation performance and different responses to cells.
Liu Y; Wu Y; Bian D; Gao S; Leeflang S; Guo H; Zheng Y; Zhou J
Acta Biomater; 2017 Oct; 62():418-433. PubMed ID: 28823717
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]