199 related articles for article (PubMed ID: 29535214)
1. Short preheating at 41°C leads to a red blood cells count comparable to that in RET channel of Sysmex analysers in samples showing cold agglutination.
La Gioia A; Fumi M; Fiorini F; Pezzati P; Balboni F; Bombara M; Marini A; Pancione Y; Solarino L; Marchese E; Sale S; Rocco V; Fiorini M
J Clin Pathol; 2018 Aug; 71(8):729-734. PubMed ID: 29535214
[TBL] [Abstract][Full Text] [Related]
2. Prospective validation of an automatic reflex test for identifying spurious elevations of mean corpuscular haemoglobin concentration due to the presence of cold agglutinins.
Falvella FS; Chibireva M; Panteghini M
Scand J Clin Lab Invest; 2021 Nov; 81(7):598-600. PubMed ID: 34346820
[TBL] [Abstract][Full Text] [Related]
3. Use of the reticulocyte channel warmed to 41°C of the XN-9000 analyzer in samples with the presence of cold agglutinins.
Roccaforte V; Sciarini F; Proserpio V; Buonocore R; Zavaroni EM; Burati S; Bussetti M; Liuzzi G; Russo RM; Porreca WP; Angelis ML; Perno CF; Bonato C; Pastori S
Hematol Transfus Cell Ther; 2021; 43(2):147-155. PubMed ID: 32199923
[TBL] [Abstract][Full Text] [Related]
4. A Rare Non-Hemolytic Case of Idiopathic Cold Agglutinin Disease.
Erkus E; Kocak MZ; Aktas G; Ozen M; Atak BM; Duman TT; Tekce BK; Savli H
Clin Lab; 2018 Jun; 64(6):1075-1078. PubMed ID: 29945320
[TBL] [Abstract][Full Text] [Related]
5. Use of RBC-O and S-MCV parameters of SYSMEX XE-2100 in a patient with RBC cold agglutination.
Wang H; Lu L; Zhou Y; Liu J; Qian M; Tang W; Jie Z; Pan S
Clin Lab; 2013; 59(1-2):217-9. PubMed ID: 23505932
[TBL] [Abstract][Full Text] [Related]
6. Spurious counts and spurious results on haematology analysers: a review. Part II: white blood cells, red blood cells, haemoglobin, red cell indices and reticulocytes.
Zandecki M; Genevieve F; Gerard J; Godon A
Int J Lab Hematol; 2007 Feb; 29(1):21-41. PubMed ID: 17224005
[TBL] [Abstract][Full Text] [Related]
7. Stability of New Erythrocyte and Reticulocyte Parameters in Testing for Anemia on the Sysmex XN 9000.
Schapkaitz E
Lab Med; 2018 Jul; 49(3):219-225. PubMed ID: 29365192
[TBL] [Abstract][Full Text] [Related]
8. Sample stability for complete blood cell count using the Sysmex XN haematological analyser.
Daves M; Zagler EM; Cemin R; Gnech F; Joos A; Platzgummer S; Lippi G
Blood Transfus; 2015 Oct; 13(4):576-82. PubMed ID: 26057491
[TBL] [Abstract][Full Text] [Related]
9. Short Prewarming at 41°C to Correct the Interference in Samples with the Presence of Cold Agglutination.
Tang W; Yang S; Zhu J; Sun L; Dai S; Wang B; Guo W; Pan B
Clin Lab; 2024 May; 70(5):. PubMed ID: 38747905
[TBL] [Abstract][Full Text] [Related]
10. [Automated hematology analysers and spurious counts Part 3. Haemoglobin, red blood cells, cell count and indices, reticulocytes].
Godon A; Genevieve F; Marteau-Tessier A; Zandecki M
Ann Biol Clin (Paris); 2012; 70(2):155-68. PubMed ID: 22484526
[TBL] [Abstract][Full Text] [Related]
11. Stability and reproducibility of ADVIA 120-measured red blood cell and platelet parameters in dogs, cats, and horses, and the use of reticulocyte haemoglobin content (CH(R)) in the diagnosis of iron deficiency.
Prins M; van Leeuwen MW; Teske E
Tijdschr Diergeneeskd; 2009 Apr; 134(7):272-8. PubMed ID: 19431960
[TBL] [Abstract][Full Text] [Related]
12. Performance evaluation of the Z2 coulter counter for WBC and RBC counting.
Peng L; Wang W; Bai L
Int J Lab Hematol; 2007 Oct; 29(5):361-8. PubMed ID: 17824917
[TBL] [Abstract][Full Text] [Related]
13. 70-year old female patient with mismatch between hematocrit and hemoglobin values: the effects of cold agglutinin on complete blood count.
Ercan S; Calışkan M; Koptur E
Biochem Med (Zagreb); 2014; 24(3):391-5. PubMed ID: 25351358
[TBL] [Abstract][Full Text] [Related]
14. A Comparative Evaluation of Performance of Sysmex XN 3000 and Horiba Yumizen H2500 Automated Complete Blood Count Analysers.
Bhola RK; Fudaly C; Rastogi S
Indian J Hematol Blood Transfus; 2024 Apr; 40(2):303-314. PubMed ID: 38708164
[TBL] [Abstract][Full Text] [Related]
15. [Erythrocytic parameters Sysmex in a case of severe haemolysis].
Ferrero-Vacher C; Senlis JÉ; Loustaunau D; Aquaronne D; Jeandel PY; Sudaka I
Ann Biol Clin (Paris); 2015; 73(6):729-32. PubMed ID: 26635053
[TBL] [Abstract][Full Text] [Related]
16. Stability of haematological parameters and its relevance on the athlete's biological passport model.
Lombardi G; Lanteri P; Colombini A; Lippi G; Banfi G
Sports Med; 2011 Dec; 41(12):1033-42. PubMed ID: 22060177
[TBL] [Abstract][Full Text] [Related]
17. [Comparative and simultaneous evaluation of three automated counters in hematology: Coulter STKS, Sysmex NE 8000, Technicon H-2].
Cart-Lamy P; Pernod G; Pirraud M; Drevait JM; Caillat D; Polack B; Kolodié L
Ann Biol Clin (Paris); 1993; 51(6):627-35. PubMed ID: 8172402
[TBL] [Abstract][Full Text] [Related]
18. [Feasibility of Preheating at 41 ℃ to Correct Red Blood Cell Parameters in the Presence of High-titer Cold Agglutinins].
Xie HX; Shen Y; Pang ZZ; Sun B; Wang ZN; Xie SH; Zhou YL
Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2021 Aug; 43(4):507-512. PubMed ID: 34494519
[TBL] [Abstract][Full Text] [Related]
19. Effect of cold agglutinins on red blood cell parameters in a trauma patient: a case report.
Topic A; Milevoj Kopcinovic L; Bronic A; Pavic M
Biochem Med (Zagreb); 2018 Oct; 28(3):031001. PubMed ID: 30429683
[TBL] [Abstract][Full Text] [Related]
20. Analytic errors in Sysmex-generated hematology results in blood from a dog with chronic lymphocytic leukemia.
Novacco M; Martini V; Grande C; Comazzi S
Vet Clin Pathol; 2015 Sep; 44(3):337-41. PubMed ID: 26147613
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]