These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

240 related articles for article (PubMed ID: 29546502)

  • 1. Biocompatibility of new materials based on nano-structured nitinol with titanium and tantalum composite surface layers: experimental analysis in vitro and in vivo.
    Sevost'yanov MA; Nasakina EO; Baikin AS; Sergienko KV; Konushkin SV; Kaplan MA; Seregin AV; Leonov AV; Kozlov VA; Shkirin AV; Bunkin NF; Kolmakov AG; Simakov SV; Gudkov SV
    J Mater Sci Mater Med; 2018 Mar; 29(3):33. PubMed ID: 29546502
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Experimental titanium alloys for dental applications.
    Faria AC; Rodrigues RC; Rosa AL; Ribeiro RF
    J Prosthet Dent; 2014 Dec; 112(6):1448-60. PubMed ID: 25088209
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Activation of human leukocytes on tantalum trabecular metal in comparison to commonly used orthopedic metal implant materials.
    Schildhauer TA; Peter E; Muhr G; Köller M
    J Biomed Mater Res A; 2009 Feb; 88(2):332-41. PubMed ID: 18286637
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Tantalum oxide/carbon nanotubes composite coatings on titanium, and their functionalization with organophosphonic molecular films: a high quality scaffold for hydroxyapatite growth.
    Maho A; Linden S; Arnould C; Detriche S; Delhalle J; Mekhalif Z
    J Colloid Interface Sci; 2012 Apr; 371(1):150-8. PubMed ID: 22284449
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Plasma-immersion ion-implanted nitinol surface with depressed nickel concentration for implants in blood.
    Maitz MF; Shevchenko N
    J Biomed Mater Res A; 2006 Feb; 76(2):356-65. PubMed ID: 16270338
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quaternary Ti-20Nb-10Zr-5Ta alloy during immersion in simulated physiological solutions: formation of layers, dissolution and biocompatibility.
    Milošev I; Hmeljak J; Žerjav G; Cör A; Calderon Moreno JM; Popa M
    J Mater Sci Mater Med; 2014 Apr; 25(4):1099-114. PubMed ID: 24452270
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cross-section transmission electron microscopy characterization of the near-surface structure of medical Nitinol superelastic tubing.
    Potapov PL; Tirry W; Schryvers D; Sivel VG; Wu MY; Aslanidis D; Zandbergen H
    J Mater Sci Mater Med; 2007 Mar; 18(3):483-92. PubMed ID: 17334699
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The role of surface oxide thickness and structure on the corrosion and nickel elution behavior of nitinol biomedical implants.
    Rosenbloom SN; Kumar P; Lasley C
    J Biomed Mater Res B Appl Biomater; 2021 Sep; 109(9):1334-1343. PubMed ID: 33410251
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Structural characterisation of oxygen diffusion hardened alpha-tantalum PVD-coatings on titanium.
    Hertl C; Koll L; Schmitz T; Werner E; Gbureck U
    Mater Sci Eng C Mater Biol Appl; 2014 Aug; 41():28-35. PubMed ID: 24907733
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reduced fibrous capsule formation at nano-engineered silicone surfaces via tantalum ion implantation.
    Park C; Lee SW; Kim J; Song EH; Jung HD; Park JU; Kim HE; Kim S; Jang TS
    Biomater Sci; 2019 Jul; 7(7):2907-2919. PubMed ID: 31089612
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Microstructure, mechanical properties and cytocompatibility of stable beta Ti-Mo-Ta sintered alloys.
    Delvat E; Gordin DM; Gloriant T; Duval JL; Nagel MD
    J Mech Behav Biomed Mater; 2008 Oct; 1(4):345-51. PubMed ID: 19627799
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Study of the Biocompatibility of Titanium-Niobium Implants by the Parameters of Their Osseointegration under Experimental Conditions.
    Olesova VN; Shashmurina VR; Shugailov IA; Olesov EE; Mirgazizov MZ
    Bull Exp Biol Med; 2019 Mar; 166(5):686-688. PubMed ID: 30903505
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In Vitro Biocompatibility of Si Alloyed Multi-Principal Element Carbide Coatings.
    Vladescu A; Titorencu I; Dekhtyar Y; Jinga V; Pruna V; Balaceanu M; Dinu M; Pana I; Vendina V; Braic M
    PLoS One; 2016; 11(8):e0161151. PubMed ID: 27571361
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In situ synthesized TiB-TiN reinforced Ti6Al4V alloy composite coatings: microstructure, tribological and in-vitro biocompatibility.
    Das M; Bhattacharya K; Dittrick SA; Mandal C; Balla VK; Sampath Kumar TS; Bandyopadhyay A; Manna I
    J Mech Behav Biomed Mater; 2014 Jan; 29():259-71. PubMed ID: 24121827
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Promotion of osteointegration under diabetic conditions by tantalum coating-based surface modification on 3-dimensional printed porous titanium implants.
    Wang L; Hu X; Ma X; Ma Z; Zhang Y; Lu Y; Li X; Lei W; Feng Y
    Colloids Surf B Biointerfaces; 2016 Dec; 148():440-452. PubMed ID: 27648775
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Titanium and zirconium based alloys modified by intensive plastic deformation and nitrogen ion implantation for biocompatible implants.
    Byeli AV; Kukareko VA; Kononov AG
    J Mech Behav Biomed Mater; 2012 Feb; 6():89-94. PubMed ID: 22301177
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fabrication of tantalum oxide/carbon nanotubes thin film composite on titanium substrate.
    Arnould C; Korányi TI; Delhalle J; Mekhalif Z
    J Colloid Interface Sci; 2010 Apr; 344(2):390-4. PubMed ID: 20122696
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Revival of pure titanium for dynamically loaded porous implants using additive manufacturing.
    Wauthle R; Ahmadi SM; Amin Yavari S; Mulier M; Zadpoor AA; Weinans H; Van Humbeeck J; Kruth JP; Schrooten J
    Mater Sci Eng C Mater Biol Appl; 2015 Sep; 54():94-100. PubMed ID: 26046272
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Critical overview of Nitinol surfaces and their modifications for medical applications.
    Shabalovskaya S; Anderegg J; Van Humbeeck J
    Acta Biomater; 2008 May; 4(3):447-67. PubMed ID: 18328796
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Tantalum-coated pedicle screws enhance implant integration.
    Shi LY; Wang A; Zang FZ; Wang JX; Pan XW; Chen HJ
    Colloids Surf B Biointerfaces; 2017 Dec; 160():22-32. PubMed ID: 28915498
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.