These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

85 related articles for article (PubMed ID: 29546781)

  • 1. Does multi-parity affect the size of the ascending thoracic aorta in women: a prospective cohort study.
    Pourafkari L; Ghaffari S; Ahmadi M; Salehi R; Mazani S; Parizad R; Nader ND
    Curr Med Res Opin; 2018 Nov; 34(11):1907-1912. PubMed ID: 29546781
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The association between severe mitral stenosis and the size of the aortic root and the ascending thoracic aorta.
    Pourafkari L; Baghbani-Oskouei A; Aslanabadi N; Enamzadeh E; Ghaffari S; Salehi R; Sohrabi B; Savadi-Oskouei S; Tajlil A; Nader ND
    Turk Kardiyol Dern Ars; 2019 Jan; 47(1):45-52. PubMed ID: 30628900
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurement of aortic root dimensions by transesophageal echocardiography in adult patients undergoing cardiac surgery.
    Maisat W; Sawasdiwipachai P; Aroonrat W; Lapmahapaisan S
    Ann Card Anaesth; 2020; 23(4):409-413. PubMed ID: 33109795
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ascending aorta diameters measured by echocardiography using both leading edge-to-leading edge and inner edge-to-inner edge conventions in healthy volunteers.
    Muraru D; Maffessanti F; Kocabay G; Peluso D; Dal Bianco L; Piasentini E; Jose SP; Iliceto S; Badano LP
    Eur Heart J Cardiovasc Imaging; 2014 Apr; 15(4):415-22. PubMed ID: 24096712
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Correlation of structural defects in the ascending aortic wall to ultrasound parameters: benefits for decision-making process in aortic valve surgery.
    Borović SD; Labudović Borović MM; Zaletel IV; Todorović VN; Dabić PA; Rakočević JT; Marinković-Erić JM; Milojević PS
    J Cardiothorac Surg; 2018 Jan; 13(1):12. PubMed ID: 29347958
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The effect of proximal anastomosis on the expansion rate of a dilated ascending aorta in coronary artery bypass surgery: a prospective study.
    Yavuz Balci A; Vural U; Aksoy R; Özdemir MF; Satilmiş S; Kizilay M; Şenocak M; Şaşkin H; Kayacioğlu I; Yekeler I
    Cardiovasc J Afr; 2017 Mar/Apr 23; 28(2):118-124. PubMed ID: 27701487
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of aging and body size on proximal and ascending aorta and aortic arch: inner edge-to-inner edge reference values in a large adult population by two-dimensional transthoracic echocardiography.
    Mirea O; Maffessanti F; Gripari P; Tamborini G; Muratori M; Fusini L; Claudia C; Fiorentini C; Plesea IE; Pepi M
    J Am Soc Echocardiogr; 2013 Apr; 26(4):419-27. PubMed ID: 23337735
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ascending Aortic Dimensions in Hypertensive Subjects: Reference Values for Two-Dimensional Echocardiography.
    Vizzardi E; Maffessanti F; Lorusso R; Sciatti E; Bonadei I; Gelsomino S; Metra M; Pepi M
    J Am Soc Echocardiogr; 2016 Sep; 29(9):827-37. PubMed ID: 27161291
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Serial echocardiographic assessment of neo-aortic regurgitation and root dimensions after the modified Ross procedure.
    Takkenberg JJ; van Herwerden LA; Galema TW; Bekkers JA; Kleyburg-Linkers VE; Eijkemans MJ; Bogers AJ
    J Heart Valve Dis; 2006 Jan; 15(1):100-6; discussion 106-7. PubMed ID: 16480020
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Normal values of proximal aorta diameters in healthy Sub Saharan Africans: The TAHES study.
    Vandroux D; Aboyans V; Houehanou YC; Saka D; Sonou A; Houinato D; Preux PM; Magne J; Lacroix P;
    Echocardiography; 2022 Apr; 39(4):576-583. PubMed ID: 35261079
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Aortic root and ascending aorta dimensions in acute aortic dissection.
    Koechlin L; Macius E; Kaufmann J; Gahl B; Reuthebuch O; Eckstein F; Berdajs DA
    Perfusion; 2020 Mar; 35(2):131-137. PubMed ID: 31364492
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Dimensions of the proximal thoracic aorta from childhood to adult age: reference values for two-dimensional echocardiography. Ligurian Group of SIEC (Italian Society of Echocardiography)].
    Cassottana P; Badano L; Piazza R; Copello F
    G Ital Cardiol; 1997 Jul; 27(7):686-96. PubMed ID: 9303859
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Aortic root dimensions and stiffness in healthy subjects.
    Vriz O; Driussi C; Bettio M; Ferrara F; D'Andrea A; Bossone E
    Am J Cardiol; 2013 Oct; 112(8):1224-9. PubMed ID: 23871268
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Aortic root geometry in patients with aortic stenosis assessed by real-time three-dimensional transesophageal echocardiography.
    Wu VC; Kaku K; Takeuchi M; Otani K; Yoshitani H; Tamura M; Abe H; Lin FC; Otsuji Y
    J Am Soc Echocardiogr; 2014 Jan; 27(1):32-41. PubMed ID: 24238752
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of feasibility and accuracy of transthoracic echocardiography versus computed tomography in patients with known ascending aortic aneurysm.
    Tamborini G; Galli CA; Maltagliati A; Andreini D; Pontone G; Quaglia C; Ballerini G; Pepi M
    Am J Cardiol; 2006 Oct; 98(7):966-9. PubMed ID: 16996884
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Aortic root dimensions in elite athletes.
    D'Andrea A; Cocchia R; Riegler L; Scarafile R; Salerno G; Gravino R; Vriz O; Citro R; Limongelli G; Di Salvo G; Cuomo S; Caso P; Russo MG; Calabrò R; Bossone E
    Am J Cardiol; 2010 Jun; 105(11):1629-34. PubMed ID: 20494674
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Aortic Diameters and Mild Functional Aortic Regurgitation in Hypertensive and Normotensive People: Do They Carry the Same Meaning?
    Vriz O; Bertin N; Bossone E; Palatini P
    J Ultrasound Med; 2018 Sep; 37(9):2171-2180. PubMed ID: 29451314
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Adjustment of sinotubular junction for aortic insufficiency secondary to ascending aortic aneurysm.
    Morimoto N; Matsumori M; Tanaka A; Munakata H; Okada K; Okita Y
    Ann Thorac Surg; 2009 Oct; 88(4):1238-43. PubMed ID: 19766813
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The sinotubular junction does not progressively dilate four years after modified subcoronary freestyle stentless tissue aortic valve replacement.
    Martin JW; Deeb GM; Bach DS
    J Heart Valve Dis; 2003 Nov; 12(6):726-33. PubMed ID: 14658814
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Aortic valve insufficiency in aneurysms of the ascending aorta: functional results following valve-sparing reconstruction].
    Pethig K; Harringer W; Haverich A
    Dtsch Med Wochenschr; 1998 Oct; 123(43):1263-8. PubMed ID: 9817995
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.