114 related articles for article (PubMed ID: 29552780)
41. 3D dose verification using tomotherapy CT detector array.
Sheng K; Jones R; Yang W; Saraiya S; Schneider B; Chen Q; Sobering G; Olivera G; Read P
Int J Radiat Oncol Biol Phys; 2012 Feb; 82(2):1013-20. PubMed ID: 21362580
[TBL] [Abstract][Full Text] [Related]
42. Development and clinical evaluation of an ionization chamber array with 3.5 mm pixel pitch for quality assurance in advanced radiotherapy techniques.
Togno M; Wilkens JJ; Menichelli D; Oechsner M; Perez-Andujar A; Morin O
Med Phys; 2016 May; 43(5):2283. PubMed ID: 27147340
[TBL] [Abstract][Full Text] [Related]
43. Validation of a modern second-check dosimetry system using a novel verification phantom.
McDonald DG; Jacqmin DJ; Mart CJ; Koch NC; Peng JL; Ashenafi MS; Fugal MA; Vanek KN
J Appl Clin Med Phys; 2017 Jan; 18(1):170-177. PubMed ID: 28291938
[TBL] [Abstract][Full Text] [Related]
44. Evaluation of a novel patient-specific quality assurance phantom for robotic single-isocentre, multiple-target stereotactic radiosurgery, and stereotactic radiotherapy.
Xu Q; Vinogradskiy Y; Grimm J; Nie W; Dupre P; Chawla AK; Bajaj G; Yang H; LaCouture T; Fan J
Br J Radiol; 2024 Feb; 97(1155):660-667. PubMed ID: 38401536
[TBL] [Abstract][Full Text] [Related]
45. The evaluation of a 2D diode array in "magic phantom" for use in high dose rate brachytherapy pretreatment quality assurance.
Espinoza A; Petasecca M; Fuduli I; Howie A; Bucci J; Corde S; Jackson M; Lerch ML; Rosenfeld AB
Med Phys; 2015 Feb; 42(2):663-673. PubMed ID: 28102606
[TBL] [Abstract][Full Text] [Related]
46. Clinical implementation of an exit detector-based dose reconstruction tool for helical tomotherapy delivery quality assurance.
Deshpande S; Xing A; Metcalfe P; Holloway L; Vial P; Geurts M
Med Phys; 2017 Oct; 44(10):5457-5466. PubMed ID: 28737014
[TBL] [Abstract][Full Text] [Related]
47. Motion as a perturbation: measurement-guided dose estimates to moving patient voxels during modulated arc deliveries.
Feygelman V; Stambaugh C; Zhang G; Hunt D; Opp D; Wolf TK; Nelms BE
Med Phys; 2013 Feb; 40(2):021708. PubMed ID: 23387731
[TBL] [Abstract][Full Text] [Related]
48. Evaluation of the MIM Symphony treatment planning system for low-dose-rate- prostate brachytherapy.
Dhanesar SK; Lim TY; Du W; Bruno TL; Frank SJ; Kudchadker RJ
J Appl Clin Med Phys; 2015 Sep; 16(5):62–75. PubMed ID: 26699290
[TBL] [Abstract][Full Text] [Related]
49. A retrospective analysis for patient-specific quality assurance of volumetric-modulated arc therapy plans.
Li G; Wu K; Peng G; Zhang Y; Bai S
Med Dosim; 2014; 39(4):309-13. PubMed ID: 24958705
[TBL] [Abstract][Full Text] [Related]
50. Performance evaluation of a CyberKnife G4 image-guided robotic stereotactic radiosurgery system.
Antypas C; Pantelis E
Phys Med Biol; 2008 Sep; 53(17):4697-718. PubMed ID: 18695294
[TBL] [Abstract][Full Text] [Related]
51. Breaking bad IMRT QA practice.
Stojadinovic S; Ouyang L; Gu X; Pompoš A; Bao Q; Solberg TD
J Appl Clin Med Phys; 2015 May; 16(3):5242. PubMed ID: 26103484
[TBL] [Abstract][Full Text] [Related]
52. Effect of the normalized prescription isodose line on the magnitude of Monte Carlo vs. pencil beam target dose differences for lung stereotactic body radiotherapy.
Zheng D; Zhang Q; Liang X; Zhu X; Verma V; Wang S; Zhou S
J Appl Clin Med Phys; 2016 Jul; 17(4):48-58. PubMed ID: 27455476
[TBL] [Abstract][Full Text] [Related]
53. Experimental evaluations of the accuracy of 3D and 4D planning in robotic tracking stereotactic body radiotherapy for lung cancers.
Chan MK; Kwong DL; Ng SC; Tong AS; Tam EK
Med Phys; 2013 Apr; 40(4):041712. PubMed ID: 23556882
[TBL] [Abstract][Full Text] [Related]
54. The use of TLD and Gafchromic film to assure submillimeter accuracy for image-guided radiosurgery.
Ho AK; Gibbs IC; Chang SD; Main B; Adler JR
Med Dosim; 2008; 33(1):36-41. PubMed ID: 18262121
[TBL] [Abstract][Full Text] [Related]
55. Variable circular collimator in robotic radiosurgery: a time-efficient alternative to a mini-multileaf collimator?
van de Water S; Hoogeman MS; Breedveld S; Nuyttens JJ; Schaart DR; Heijmen BJ
Int J Radiat Oncol Biol Phys; 2011 Nov; 81(3):863-70. PubMed ID: 21377286
[TBL] [Abstract][Full Text] [Related]
56. Three-dimensional portal image-based dose reconstruction in a virtual phantom for rapid evaluation of IMRT plans.
Ansbacher W
Med Phys; 2006 Sep; 33(9):3369-82. PubMed ID: 17022233
[TBL] [Abstract][Full Text] [Related]
57. Investigating the clinical advantages of a robotic linac equipped with a multileaf collimator in the treatment of brain and prostate cancer patients.
McGuinness CM; Gottschalk AR; Lessard E; Nakamura JL; Pinnaduwage D; Pouliot J; Sims C; Descovich M
J Appl Clin Med Phys; 2015 Sep; 16(5):284–295. PubMed ID: 26699309
[TBL] [Abstract][Full Text] [Related]
58. Plan delivery quality assurance for CyberKnife: Statistical process control analysis of 350 film-based patient-specific QAs.
Bellec J; Delaby N; Jouyaux F; Perdrieux M; Bouvier J; Sorel S; Henry O; Lafond C
Phys Med; 2017 Jul; 39():50-58. PubMed ID: 28711188
[TBL] [Abstract][Full Text] [Related]
59. Clinical implementation and evaluation of the Acuros dose calculation algorithm.
Yan C; Combine AG; Bednarz G; Lalonde RJ; Hu B; Dickens K; Wynn R; Pavord DC; Saiful Huq M
J Appl Clin Med Phys; 2017 Sep; 18(5):195-209. PubMed ID: 28834214
[TBL] [Abstract][Full Text] [Related]
60. The dosimetric impact of the prescription isodose line (IDL) on the quality of robotic stereotactic radiosurgery (SRS) plans.
Xu Q; Fan J; Grimm J; LaCouture T; Asbell S; Park JH; Kubicek G
Med Phys; 2017 Dec; 44(12):6159-6165. PubMed ID: 29064585
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]