BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

200 related articles for article (PubMed ID: 29554489)

  • 1. Hartmann characterization of the PEEM-3 aberration-corrected X-ray photoemission electron microscope.
    Scholl A; Marcus MA; Doran A; Nasiatka JR; Young AT; MacDowell AA; Streubel R; Kent N; Feng J; Wan W; Padmore HA
    Ultramicroscopy; 2018 May; 188():77-84. PubMed ID: 29554489
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The objective lens of the electron microscope with correction of spherical and axial chromatic aberrations.
    Bimurzaev SB; Aldiyarov NU; Yakushev EM
    Microscopy (Oxf); 2017 Oct; 66(5):356-365. PubMed ID: 29016920
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Design for an aberration corrected scanning electron microscope using miniature electron mirrors.
    Dohi H; Kruit P
    Ultramicroscopy; 2018 Jun; 189():1-23. PubMed ID: 29574382
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A new aberration-corrected, energy-filtered LEEM/PEEM instrument. I. Principles and design.
    Tromp RM; Hannon JB; Ellis AW; Wan W; Berghaus A; Schaff O
    Ultramicroscopy; 2010 Jun; 110(7):852-61. PubMed ID: 20395048
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Catadioptric aberration correction in cathode lens microscopy.
    Tromp RM
    Ultramicroscopy; 2015 Apr; 151():191-198. PubMed ID: 25458190
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Measuring chromatic aberration in LEEM/PEEM.
    Tromp RM
    Ultramicroscopy; 2019 Apr; 199():46-49. PubMed ID: 30772717
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Theoretical estimates of spherical and chromatic aberration in photoemission electron microscopy.
    Fitzgerald JPS; Word RC; Könenkamp R
    Ultramicroscopy; 2016 Jan; 160():252-255. PubMed ID: 26555325
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Aberration corrected STEM by means of diffraction gratings.
    Linck M; Ercius PA; Pierce JS; McMorran BJ
    Ultramicroscopy; 2017 Nov; 182():36-43. PubMed ID: 28651199
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An adjustable electron achromat for cathode lens microscopy.
    Tromp RM
    Ultramicroscopy; 2015 Dec; 159 Pt 3():497-502. PubMed ID: 25825026
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Future trends in aberration-corrected electron microscopy.
    Rose HH
    Philos Trans A Math Phys Eng Sci; 2009 Sep; 367(1903):3809-23. PubMed ID: 19687067
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Tuning fifth-order aberrations in a quadrupole-octupole corrector.
    Lupini AR; Pennycook SJ
    Microsc Microanal; 2012 Aug; 18(4):699-704. PubMed ID: 22846922
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of residual aberration in fifth-order geometrical aberration correctors.
    Morishita S; Kohno Y; Hosokawa F; Suenaga K; Sawada H
    Microscopy (Oxf); 2018 Jun; 67(3):156-163. PubMed ID: 29474670
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A new aberration-corrected, energy-filtered LEEM/PEEM instrument II. Operation and results.
    Tromp RM; Hannon JB; Wan W; Berghaus A; Schaff O
    Ultramicroscopy; 2013 Apr; 127():25-39. PubMed ID: 22925736
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Current and future aberration correctors for the improvement of resolution in electron microscopy.
    Haider M; Hartel P; Müller H; Uhlemann S; Zach J
    Philos Trans A Math Phys Eng Sci; 2009 Sep; 367(1903):3665-82. PubMed ID: 19687059
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Theoretical study on sixth-order geometrical aberration correction.
    Morishita S; Sawada H
    Ultramicroscopy; 2022 Sep; 239():113569. PubMed ID: 35690037
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Aberration correction for low voltage optimized transmission electron microscopy.
    Bačovský J
    MethodsX; 2018; 5():1033-1047. PubMed ID: 30225204
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improvements in the X-ray analytical capabilities of a scanning transmission electron microscope by spherical-aberration correction.
    Watanabe M; Ackland DW; Burrows A; Kiely CJ; Williams DB; Krivanek OL; Dellby N; Murfitt MF; Szilagyi Z
    Microsc Microanal; 2006 Dec; 12(6):515-26. PubMed ID: 19830944
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Aberration-corrected STEM for atomic-resolution imaging and analysis.
    Krivanek OL; Lovejoy TC; Dellby N
    J Microsc; 2015 Sep; 259(3):165-72. PubMed ID: 25939916
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Time-resolved magnetic imaging in an aberration-corrected, energy-filtered photoemission electron microscope.
    Nickel F; Gottlob DM; Krug IP; Doganay H; Cramm S; Kaiser AM; Lin G; Makarov D; Schmidt OG; Schneider CM
    Ultramicroscopy; 2013 Jul; 130():54-62. PubMed ID: 23588068
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Chicago aberration correction work.
    Beck VD
    Ultramicroscopy; 2012 Dec; 123():22-7. PubMed ID: 22795625
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.