These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

307 related articles for article (PubMed ID: 29565197)

  • 1. Optimal Sampling Duration for Continuous Glucose Monitoring to Determine Long-Term Glycemic Control.
    Riddlesworth TD; Beck RW; Gal RL; Connor CG; Bergenstal RM; Lee S; Willi SM
    Diabetes Technol Ther; 2018 Apr; 20(4):314-316. PubMed ID: 29565197
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Long-term glycemic control and glucose variability assessed with continuous glucose monitoring in a pediatric population with type 1 diabetes: Determination of optimal sampling duration.
    Piona C; Marigliano M; Mozzillo E; Franzese A; Zanfardino A; Iafusco D; Maltoni G; Zucchini S; Delvecchio M; Maffeis C
    Pediatr Diabetes; 2020 Dec; 21(8):1485-1492. PubMed ID: 32935887
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optimal sampling intervals to assess long-term glycemic control using continuous glucose monitoring.
    Xing D; Kollman C; Beck RW; Tamborlane WV; Laffel L; Buckingham BA; Wilson DM; Weinzimer S; Fiallo-Scharer R; Ruedy KJ;
    Diabetes Technol Ther; 2011 Mar; 13(3):351-8. PubMed ID: 21299401
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of Continuous Glucose Monitoring on Glycemic Control in Adolescents and Young Adults With Type 1 Diabetes: A Randomized Clinical Trial.
    Laffel LM; Kanapka LG; Beck RW; Bergamo K; Clements MA; Criego A; DeSalvo DJ; Goland R; Hood K; Liljenquist D; Messer LH; Monzavi R; Mouse TJ; Prahalad P; Sherr J; Simmons JH; Wadwa RP; Weinstock RS; Willi SM; Miller KM; ;
    JAMA; 2020 Jun; 323(23):2388-2396. PubMed ID: 32543683
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The Optimal Duration of a Run-In Period to Initiate Continuous Glucose Monitoring for a Randomized Trial.
    Raghinaru D; Calhoun P; Bergenstal RM; Beck RW
    Diabetes Technol Ther; 2022 Dec; 24(12):868-872. PubMed ID: 35920822
    [No Abstract]   [Full Text] [Related]  

  • 6. Integrated sensor-augmented pump therapy systems [the MiniMed® Paradigm™ Veo system and the Vibe™ and G4® PLATINUM CGM (continuous glucose monitoring) system] for managing blood glucose levels in type 1 diabetes: a systematic review and economic evaluation.
    Riemsma R; Corro Ramos I; Birnie R; Büyükkaramikli N; Armstrong N; Ryder S; Duffy S; Worthy G; Al M; Severens J; Kleijnen J
    Health Technol Assess; 2016 Feb; 20(17):v-xxxi, 1-251. PubMed ID: 26933827
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of Continuous Glucose Monitoring on Hypoglycemia in Older Adults With Type 1 Diabetes: A Randomized Clinical Trial.
    Pratley RE; Kanapka LG; Rickels MR; Ahmann A; Aleppo G; Beck R; Bhargava A; Bode BW; Carlson A; Chaytor NS; Fox DS; Goland R; Hirsch IB; Kruger D; Kudva YC; Levy C; McGill JB; Peters A; Philipson L; Philis-Tsimikas A; Pop-Busui R; Shah VN; Thompson M; Vendrame F; Verdejo A; Weinstock RS; Young L; Miller KM;
    JAMA; 2020 Jun; 323(23):2397-2406. PubMed ID: 32543682
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A Feasibility Study of Paired Continuous Glucose Monitoring Intrapartum and in the Newborn in Pregnancies Complicated by Type 1 Diabetes.
    Stewart ZA; Thomson L; Murphy HR; Beardsall K
    Diabetes Technol Ther; 2019 Jan; 21(1):20-27. PubMed ID: 30620640
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of the relationship between glycated hemoglobin A1c and mean glucose levels derived from the professional continuous flash glucose monitoring system.
    Yamada M; Okada S; Oda H; Nakajima Y; C Bastie C; Kasai Y; Osaki A; Shimoda Y; Shibusawa R; Uehara R; Saito T; Ozawa A; Yamada E
    Endocr J; 2020 May; 67(5):531-536. PubMed ID: 32023560
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Exploring the inter-subject variability in the relationship between glucose monitoring metrics and glycated hemoglobin for pediatric patients with type 1 diabetes.
    Bosoni P; Calcaterra V; Tibollo V; Malovini A; Zuccotti G; Mameli C; Sacchi L; Bellazzi R; Larizza C
    J Pediatr Endocrinol Metab; 2021 May; 34(5):619-625. PubMed ID: 33823102
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Glycemic Control in Patients with Type 1 Diabetes: Comparison of Holidays
    Al Hayek A; Alwin Robert A; Almonea KI; Al Dawish MA
    Curr Diabetes Rev; 2024; 20(9):e040124225257. PubMed ID: 38310482
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Beyond HbA1c.
    Bloomgarden Z
    J Diabetes; 2017 Dec; 9(12):1052-1053. PubMed ID: 28792665
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Translating glycated hemoglobin A1c into time spent in glucose target range: A multicenter study.
    Petersson J; Åkesson K; Sundberg F; Särnblad S
    Pediatr Diabetes; 2019 May; 20(3):339-344. PubMed ID: 30652407
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Use of continuous glucose monitoring as an outcome measure in clinical trials.
    Beck RW; Calhoun P; Kollman C
    Diabetes Technol Ther; 2012 Oct; 14(10):877-82. PubMed ID: 23013201
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of Continuous Glucose Monitoring on Glycemic Control in Adults With Type 1 Diabetes Using Insulin Injections: The DIAMOND Randomized Clinical Trial.
    Beck RW; Riddlesworth T; Ruedy K; Ahmann A; Bergenstal R; Haller S; Kollman C; Kruger D; McGill JB; Polonsky W; Toschi E; Wolpert H; Price D;
    JAMA; 2017 Jan; 317(4):371-378. PubMed ID: 28118453
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Limitations of 14-Day Continuous Glucose Monitoring Sampling for Assessment of Hypoglycemia and Glycemic Variability in Type 1 Diabetes.
    Akturk HK
    Diabetes Technol Ther; 2024 Jul; 26(7):503-508. PubMed ID: 38300516
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effectiveness of the freestyle libre 2 flash glucose monitoring system on diabetes-self-management practices and glycemic parameters among patients with type 1 diabetes using insulin pump.
    Al Hayek AA; Robert AA; Al Dawish MA
    Diabetes Metab Syndr; 2021; 15(5):102265. PubMed ID: 34488057
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Continuous Glucose Monitoring and Insulin Informed Advisory System with Automated Titration and Dosing of Insulin Reduces Glucose Variability in Type 1 Diabetes Mellitus.
    Breton MD; Patek SD; Lv D; Schertz E; Robic J; Pinnata J; Kollar L; Barnett C; Wakeman C; Oliveri M; Fabris C; Chernavvsky D; Kovatchev BP; Anderson SM
    Diabetes Technol Ther; 2018 Aug; 20(8):531-540. PubMed ID: 29979618
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Real-time CGM Is Superior to Flash Glucose Monitoring for Glucose Control in Type 1 Diabetes: The CORRIDA Randomized Controlled Trial.
    Hásková A; Radovnická L; Petruželková L; Parkin CG; Grunberger G; Horová E; Navrátilová V; Kádě O; Matoulek M; Prázný M; Šoupal J
    Diabetes Care; 2020 Nov; 43(11):2744-2750. PubMed ID: 32859607
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The Relationship of Hemoglobin A1C to Time-in-Range in Patients with Diabetes.
    Vigersky RA; McMahon C
    Diabetes Technol Ther; 2019 Feb; 21(2):81-85. PubMed ID: 30575414
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.