These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
78 related articles for article (PubMed ID: 29569137)
1. Correction to: Point shear wave ultrasound elastography with Esaote compared to real-time 2D shear wave elastography with supersonic imagine for the quantification of liver stiffness. Mulazzani L; Salvatore V; Ravaioli F; Allegretti G; Matassoni F; Granata R; Ferrarini A; Stefanescu H; Piscaglia F J Ultrasound; 2018 Jun; 21(2):169. PubMed ID: 29569137 [TBL] [Abstract][Full Text] [Related]
2. Ultrasound Shear Wave Elastography for Liver Disease. A Critical Appraisal of the Many Actors on the Stage. Piscaglia F; Salvatore V; Mulazzani L; Cantisani V; Schiavone C Ultraschall Med; 2016 Feb; 37(1):1-5. PubMed ID: 26871407 [TBL] [Abstract][Full Text] [Related]
3. Shear wave elastography with a new reliability indicator. Dietrich CF; Dong Y J Ultrason; 2016 Sep; 16(66):281-7. PubMed ID: 27679731 [TBL] [Abstract][Full Text] [Related]
4. Accuracy of real-time shear wave elastography in the assessment of normal liver tissue in the guinea pig (cavia porcellus). Glińska-Suchocka K; Kubiak K; Spużak J; Jankowski M; Borusewicz P Pol J Vet Sci; 2017 Mar; 20(1):51-56. PubMed ID: 28525336 [TBL] [Abstract][Full Text] [Related]
5. An Artifact in Supersonic Shear Wave Elastography. Lin CY; Chen PY; Shau YW; Wang CL Ultrasound Med Biol; 2017 Feb; 43(2):517-530. PubMed ID: 27793363 [TBL] [Abstract][Full Text] [Related]
6. Reproducibility of 2-Dimensional Shear Wave Elastography Assessment of the Liver: A Direct Comparison With Point Shear Wave Elastography in Healthy Volunteers. Fang C; Konstantatou E; Romanos O; Yusuf GT; Quinlan DJ; Sidhu PS J Ultrasound Med; 2017 Aug; 36(8):1563-1569. PubMed ID: 28370146 [TBL] [Abstract][Full Text] [Related]
7. Feasibility and Diagnostic Accuracy of Supersonic Shear-Wave Elastography for the Assessment of Liver Stiffness and Liver Fibrosis in Children: A Pilot Study of 96 Patients. Franchi-Abella S; Corno L; Gonzales E; Antoni G; Fabre M; Ducot B; Pariente D; Gennisson JL; Tanter M; Corréas JM Radiology; 2016 Feb; 278(2):554-62. PubMed ID: 26305193 [TBL] [Abstract][Full Text] [Related]
8. Hepatic fibrosis: prospective comparison of MR elastography and US shear-wave elastography for evaluation. Yoon JH; Lee JM; Joo I; Lee ES; Sohn JY; Jang SK; Lee KB; Han JK; Choi BI Radiology; 2014 Dec; 273(3):772-82. PubMed ID: 25007047 [TBL] [Abstract][Full Text] [Related]
9. Ultrasound elastography of the lower uterine segment in women with a previous cesarean section: Comparison of in-/ex-vivo elastography versus tensile-stress-strain-rupture analysis. Seliger G; Chaoui K; Lautenschläger C; Jenderka KV; Kunze C; Hiller GGR; Tchirikov M Eur J Obstet Gynecol Reprod Biol; 2018 Jun; 225():172-180. PubMed ID: 29729520 [TBL] [Abstract][Full Text] [Related]
10. On the effects of reflected waves in transient shear wave elastography. Deffieux T; Gennisson JL; Bercoff J; Tanter M IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Oct; 58(10):2032-5. PubMed ID: 21989866 [TBL] [Abstract][Full Text] [Related]
11. Investigating liver stiffness and viscosity for fibrosis, steatosis and activity staging using shear wave elastography. Deffieux T; Gennisson JL; Bousquet L; Corouge M; Cosconea S; Amroun D; Tripon S; Terris B; Mallet V; Sogni P; Tanter M; Pol S J Hepatol; 2015 Feb; 62(2):317-24. PubMed ID: 25251998 [TBL] [Abstract][Full Text] [Related]
12. Quantification of kidney fibrosis using ultrasonic shear wave elastography: experimental study with a rabbit model. Moon SK; Kim SY; Cho JY; Kim SH J Ultrasound Med; 2015 May; 34(5):869-77. PubMed ID: 25911705 [TBL] [Abstract][Full Text] [Related]
13. Accuracy of real-time shear wave elastography for assessing liver fibrosis in chronic hepatitis C: a pilot study. Ferraioli G; Tinelli C; Dal Bello B; Zicchetti M; Filice G; Filice C; Hepatology; 2012 Dec; 56(6):2125-33. PubMed ID: 22767302 [TBL] [Abstract][Full Text] [Related]
14. A comparative study of strain and shear-wave elastography in an elasticity phantom. Carlsen JF; Pedersen MR; Ewertsen C; Săftoiu A; Lönn L; Rafaelsen SR; Nielsen MB AJR Am J Roentgenol; 2015 Mar; 204(3):W236-42. PubMed ID: 25714307 [TBL] [Abstract][Full Text] [Related]
16. Clinical acceptance testing and scanner comparison of ultrasound shear wave elastography. Long Z; Tradup DJ; Song P; Stekel SF; Chen S; Glazebrook KN; Hangiandreou NJ J Appl Clin Med Phys; 2018 May; 19(3):336-342. PubMed ID: 29542277 [TBL] [Abstract][Full Text] [Related]
17. Transient and 2-Dimensional Shear-Wave Elastography Provide Comparable Assessment of Alcoholic Liver Fibrosis and Cirrhosis. Thiele M; Detlefsen S; Sevelsted Møller L; Madsen BS; Fuglsang Hansen J; Fialla AD; Trebicka J; Krag A Gastroenterology; 2016 Jan; 150(1):123-33. PubMed ID: 26435270 [TBL] [Abstract][Full Text] [Related]
18. Quantification of elasticity changes in the myometrium during labor using Supersonic Shear Imaging: a feasibility study. Gennisson JL; Muller M; Gabor P; Frydman R; Musset D; Tanter M; Ami O Ultrasonics; 2015 Feb; 56():183-8. PubMed ID: 25189820 [TBL] [Abstract][Full Text] [Related]
19. Two-dimensional shear-wave elastography on conventional ultrasound scanners with time-aligned sequential tracking (TAST) and comb-push ultrasound shear elastography (CUSE). Song P; Macdonald M; Behler R; Lanning J; Wang M; Urban M; Manduca A; Zhao H; Callstrom M; Alizad A; Greenleaf J; Chen S IEEE Trans Ultrason Ferroelectr Freq Control; 2015 Feb; 62(2):290-302. PubMed ID: 25643079 [TBL] [Abstract][Full Text] [Related]
20. Liver and spleen elastography using supersonic shear imaging for the non-invasive diagnosis of cirrhosis severity and oesophageal varices. Cassinotto C; Charrie A; Mouries A; Lapuyade B; Hiriart JB; Vergniol J; Gaye D; Hocquelet A; Charbonnier M; Foucher J; Laurent F; Chermak F; Montaudon M; de Ledinghen V Dig Liver Dis; 2015 Aug; 47(8):695-701. PubMed ID: 25959234 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]