These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 29569728)

  • 1. Automatic intraoperative stitching of nonoverlapping cone-beam CT acquisitions.
    Fotouhi J; Fuerst B; Unberath M; Reichenstein S; Lee SC; Johnson AA; Osgood GM; Armand M; Navab N
    Med Phys; 2018 Jun; 45(6):2463-2475. PubMed ID: 29569728
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Can real-time RGBD enhance intraoperative Cone-Beam CT?
    Fotouhi J; Fuerst B; Wein W; Navab N
    Int J Comput Assist Radiol Surg; 2017 Jul; 12(7):1211-1219. PubMed ID: 28343303
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Calibration of RGBD camera and cone-beam CT for 3D intra-operative mixed reality visualization.
    Lee SC; Fuerst B; Fotouhi J; Fischer M; Osgood G; Navab N
    Int J Comput Assist Radiol Surg; 2016 Jun; 11(6):967-75. PubMed ID: 27059022
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Automatic image-to-world registration based on x-ray projections in cone-beam CT-guided interventions.
    Hamming NM; Daly MJ; Irish JC; Siewerdsen JH
    Med Phys; 2009 May; 36(5):1800-12. PubMed ID: 19544799
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pose-aware C-arm for automatic re-initialization of interventional 2D/3D image registration.
    Fotouhi J; Fuerst B; Johnson A; Lee SC; Taylor R; Osgood G; Navab N; Armand M
    Int J Comput Assist Radiol Surg; 2017 Jul; 12(7):1221-1230. PubMed ID: 28527025
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mobile C-arm cone-beam CT for guidance of spine surgery: image quality, radiation dose, and integration with interventional guidance.
    Schafer S; Nithiananthan S; Mirota DJ; Uneri A; Stayman JW; Zbijewski W; Schmidgunst C; Kleinszig G; Khanna AJ; Siewerdsena JH
    Med Phys; 2011 Aug; 38(8):4563-74. PubMed ID: 21928628
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Automated target tracking in kilovoltage images using dynamic templates of fiducial marker clusters.
    Campbell WG; Miften M; Jones BL
    Med Phys; 2017 Feb; 44(2):364-374. PubMed ID: 28035655
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Automatic tracking of arbitrarily shaped implanted markers in kilovoltage projection images: a feasibility study.
    Regmi R; Lovelock DM; Hunt M; Zhang P; Pham H; Xiong J; Yorke ED; Goodman KA; Rimner A; Mostafavi H; Mageras GS
    Med Phys; 2014 Jul; 41(7):071906. PubMed ID: 24989384
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Robust methods for automatic image-to-world registration in cone-beam CT interventional guidance.
    Dang H; Otake Y; Schafer S; Stayman JW; Kleinszig G; Siewerdsen JH
    Med Phys; 2012 Oct; 39(10):6484-98. PubMed ID: 23039683
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accurate 3D data stitching in circular cone-beam micro-CT.
    Ji C
    J Xray Sci Technol; 2010; 18(2):99-110. PubMed ID: 20495238
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fusion of augmented reality imaging with the endoscopic view for endonasal skull base surgery; a novel application for surgical navigation based on intraoperative cone beam computed tomography and optical tracking.
    Lai M; Skyrman S; Shan C; Babic D; Homan R; Edström E; Persson O; Burström G; Elmi-Terander A; Hendriks BHW; de With PHN
    PLoS One; 2020; 15(1):e0227312. PubMed ID: 31945082
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Robust automatic segmentation of multiple implanted cylindrical gold fiducial markers in cone-beam CT projections.
    Fledelius W; Worm E; Elstrøm UV; Petersen JB; Grau C; Høyer M; Poulsen PR
    Med Phys; 2011 Dec; 38(12):6351-61. PubMed ID: 22149818
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [3D augmented reality visualization for navigated osteosynthesis of pelvic fractures].
    Befrui N; Fischer M; Fuerst B; Lee SC; Fotouhi J; Weidert S; Johnson A; Euler E; Osgood G; Navab N; Böcker W
    Unfallchirurg; 2018 Apr; 121(4):264-270. PubMed ID: 29500506
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A learning-based method for online adjustment of C-arm Cone-beam CT source trajectories for artifact avoidance.
    Thies M; Zäch JN; Gao C; Taylor R; Navab N; Maier A; Unberath M
    Int J Comput Assist Radiol Surg; 2020 Nov; 15(11):1787-1796. PubMed ID: 32840721
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A mobile isocentric C-arm for intraoperative cone-beam CT: Technical assessment of dose and 3D imaging performance.
    Sheth NM; De Silva T; Uneri A; Ketcha M; Han R; Vijayan R; Osgood GM; Siewerdsen JH
    Med Phys; 2020 Mar; 47(3):958-974. PubMed ID: 31863480
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An on-board surgical tracking and video augmentation system for C-arm image guidance.
    Reaungamornrat S; Otake Y; Uneri A; Schafer S; Mirota DJ; Nithiananthan S; Stayman JW; Kleinszig G; Khanna AJ; Taylor RH; Siewerdsen JH
    Int J Comput Assist Radiol Surg; 2012 Sep; 7(5):647-65. PubMed ID: 22539008
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Panoramic cone beam computed tomography.
    Chang J; Zhou L; Wang S; Clifford Chao KS
    Med Phys; 2012 May; 39(5):2930-46. PubMed ID: 22559664
    [TBL] [Abstract][Full Text] [Related]  

  • 18. TREK: an integrated system architecture for intraoperative cone-beam CT-guided surgery.
    Uneri A; Schafer S; Mirota DJ; Nithiananthan S; Otake Y; Taylor RH; Gallia GL; Khanna AJ; Lee S; Reh DD; Siewerdsen JH
    Int J Comput Assist Radiol Surg; 2012 Jan; 7(1):159-73. PubMed ID: 21744085
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fully automatic online geometric calibration for non-circular cone-beam CT orbits using fiducials with unknown placement.
    Ma YQ; Reynolds T; Ehtiati T; Weiss C; Hong K; Theodore N; Gang GJ; Stayman JW
    Med Phys; 2024 May; 51(5):3245-3264. PubMed ID: 38573172
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Integration of optical imaging with a small animal irradiator.
    Weersink RA; Ansell S; Wang A; Wilson G; Shah D; Lindsay PE; Jaffray DA
    Med Phys; 2014 Oct; 41(10):102701. PubMed ID: 25281980
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.