BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 29570008)

  • 1. Intraoperative use of transcranial motor/sensory evoked potential monitoring in the clipping of intracranial aneurysms: evaluation of false-positive and false-negative cases.
    Chung J; Park W; Hong SH; Park JC; Ahn JS; Kwun BD; Lee SA; Kim SH; Jeon JY
    J Neurosurg; 2018 Mar; 130(3):936-948. PubMed ID: 29570008
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effectiveness and Limitations of Intraoperative Monitoring with Combined Motor and Somatosensory Evoked Potentials During Surgical Clipping of Unruptured Intracranial Aneurysms.
    Choi HH; Ha EJ; Cho WS; Kang HS; Kim JE
    World Neurosurg; 2017 Dec; 108():738-747. PubMed ID: 28951267
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Monitoring of motor evoked potentials compared with somatosensory evoked potentials and microvascular Doppler ultrasonography in cerebral aneurysm surgery.
    Neuloh G; Schramm J
    J Neurosurg; 2004 Mar; 100(3):389-99. PubMed ID: 15035273
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intraoperative neuromonitoring during microsurgical clipping for unruptured anterior choroidal artery aneurysm.
    Byoun HS; Oh CW; Kwon OK; Lee SU; Ban SP; Kim SH; Kim T; Bang JS; Kim SU; Choi J; Park KS
    Clin Neurol Neurosurg; 2019 Nov; 186():105503. PubMed ID: 31494461
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of combined use of transcranial and direct cortical motor evoked potential monitoring during unruptured aneurysm surgery.
    Motoyama Y; Kawaguchi M; Yamada S; Nakagawa I; Nishimura F; Hironaka Y; Park YS; Hayashi H; Abe R; Nakase H
    Neurol Med Chir (Tokyo); 2011; 51(1):15-22. PubMed ID: 21273739
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Rapid ventricular pacing for clip reconstruction of complex unruptured intracranial aneurysms: results of an interdisciplinary prospective trial.
    Konczalla J; Platz J; Fichtlscherer S; Mutlak H; Strouhal U; Seifert V
    J Neurosurg; 2018 Jun; 128(6):1741-1752. PubMed ID: 28820303
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Discrepancy between voluntary movement and motor-evoked potentials in evaluation of motor function during clipping of anterior circulation aneurysms.
    Suzuki K; Mikami T; Sugino T; Wanibuchi M; Miyamoto S; Hashimoto N; Mikuni N
    World Neurosurg; 2014 Dec; 82(6):e739-45. PubMed ID: 24036339
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ischemia changes and tolerance ratio of evoked potential monitoring in intracranial aneurysm surgery.
    Kang D; Yao P; Wu Z; Yu L
    Clin Neurol Neurosurg; 2013 May; 115(5):552-6. PubMed ID: 22795547
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of false-negative/positive results of intraoperative evoked potential monitoring between no and partial neuromuscular blockade in patients receiving propofol/remifentanil-based anesthesia during cerebral aneurysm clipping surgery: A retrospective analysis of 685 patients.
    Kim SH; Jin SJ; Karm MH; Moon YJ; Jeong HW; Kim JW; Ha SI; Kim JU
    Medicine (Baltimore); 2016 Aug; 95(34):e4725. PubMed ID: 27559984
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Microsurgical Clipping of Intracranial Aneurysms Assisted by Neurophysiological Monitoring, Microvascular Flow Probe, and ICG-VA: Outcomes and Intraoperative Data on a Multimodal Strategy.
    Della Puppa A; Rossetto M; Volpin F; Rustemi O; Grego A; Gerardi A; Ortolan R; Causin F; Munari M; Scienza R
    World Neurosurg; 2018 May; 113():e336-e344. PubMed ID: 29452324
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The efficacy of motor-evoked potentials on cerebral aneurysm surgery and new-onset postoperative motor deficits.
    Irie T; Yoshitani K; Ohnishi Y; Shinzawa M; Miura N; Kusaka Y; Miyazaki S; Miyamoto S
    J Neurosurg Anesthesiol; 2010 Jul; 22(3):247-51. PubMed ID: 20548170
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Intraoperative Combined Use of Somatosensory Evoked Potential, Microvascular Doppler Sonography, and Indocyanine Green Angiography in Clipping of Intracranial Aneurysm.
    Li Z; Zhang G; Huang G; Wang Z; Tan H; Liu J; Li A
    Med Sci Monit; 2016 Feb; 22():373-9. PubMed ID: 26845425
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Somatosensory-evoked potential monitoring during instrumented scoliosis corrective procedures: validity revisited.
    Thirumala PD; Bodily L; Tint D; Ward WT; Deeney VF; Crammond DJ; Habeych ME; Balzer JR
    Spine J; 2014 Aug; 14(8):1572-80. PubMed ID: 24361128
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Diagnostic accuracy of somatosensory evoked potentials during intracranial aneurysm clipping for perioperative stroke.
    Kashkoush AI; Nguyen C; Balzer J; Habeych M; Crammond DJ; Thirumala PD
    J Clin Monit Comput; 2020 Aug; 34(4):811-819. PubMed ID: 31399827
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The incidence of and risk factors for ischemic complications after microsurgical clipping of unruptured middle cerebral artery aneurysms and the efficacy of intraoperative monitoring of somatosensory evoked potentials: A retrospective study.
    Byoun HS; Bang JS; Oh CW; Kwon OK; Hwang G; Han JH; Kim T; Lee SU; Jo SR; Kim DG; Park KS
    Clin Neurol Neurosurg; 2016 Dec; 151():128-135. PubMed ID: 27838495
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Impact of changes in intraoperative somatosensory evoked potentials on stroke rates after clipping of intracranial aneurysms.
    Wicks RT; Pradilla G; Raza SM; Hadelsberg U; Coon AL; Huang J; Tamargo RJ
    Neurosurgery; 2012 May; 70(5):1114-24; discussion 1124. PubMed ID: 22067420
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transcranial motor evoked potential monitoring during the surgical clipping of unruptured intracranial aneurysms.
    Yeon JY; Seo DW; Hong SC; Kim JS
    J Neurol Sci; 2010 Jun; 293(1-2):29-34. PubMed ID: 20409559
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Motor evoked potential monitoring during surgery of middle cerebral artery aneurysms: a cohort study.
    Yue Q; Zhu W; Gu Y; Xu B; Lang L; Song J; Cai J; Xu G; Chen L; Mao Y
    World Neurosurg; 2014 Dec; 82(6):1091-9. PubMed ID: 25220340
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A new criterion for the alarm point using a combination of waveform amplitude and onset latency in Br(E)-MsEP monitoring in spine surgery.
    Kobayashi K; Ando K; Shinjo R; Ito K; Tsushima M; Morozumi M; Tanaka S; Machino M; Ota K; Ishiguro N; Imagama S
    J Neurosurg Spine; 2018 Oct; 29(4):435-441. PubMed ID: 30052151
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Differential rates of false-positive findings in transcranial electric motor evoked potential monitoring when using inhalational anesthesia versus total intravenous anesthesia during spine surgeries.
    Tamkus AA; Rice KS; Kim HL
    Spine J; 2014 Aug; 14(8):1440-6. PubMed ID: 24209393
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.