168 related articles for article (PubMed ID: 29570008)
1. Intraoperative use of transcranial motor/sensory evoked potential monitoring in the clipping of intracranial aneurysms: evaluation of false-positive and false-negative cases.
Chung J; Park W; Hong SH; Park JC; Ahn JS; Kwun BD; Lee SA; Kim SH; Jeon JY
J Neurosurg; 2018 Mar; 130(3):936-948. PubMed ID: 29570008
[TBL] [Abstract][Full Text] [Related]
2. Effectiveness and Limitations of Intraoperative Monitoring with Combined Motor and Somatosensory Evoked Potentials During Surgical Clipping of Unruptured Intracranial Aneurysms.
Choi HH; Ha EJ; Cho WS; Kang HS; Kim JE
World Neurosurg; 2017 Dec; 108():738-747. PubMed ID: 28951267
[TBL] [Abstract][Full Text] [Related]
3. Monitoring of motor evoked potentials compared with somatosensory evoked potentials and microvascular Doppler ultrasonography in cerebral aneurysm surgery.
Neuloh G; Schramm J
J Neurosurg; 2004 Mar; 100(3):389-99. PubMed ID: 15035273
[TBL] [Abstract][Full Text] [Related]
4. Intraoperative neuromonitoring during microsurgical clipping for unruptured anterior choroidal artery aneurysm.
Byoun HS; Oh CW; Kwon OK; Lee SU; Ban SP; Kim SH; Kim T; Bang JS; Kim SU; Choi J; Park KS
Clin Neurol Neurosurg; 2019 Nov; 186():105503. PubMed ID: 31494461
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of combined use of transcranial and direct cortical motor evoked potential monitoring during unruptured aneurysm surgery.
Motoyama Y; Kawaguchi M; Yamada S; Nakagawa I; Nishimura F; Hironaka Y; Park YS; Hayashi H; Abe R; Nakase H
Neurol Med Chir (Tokyo); 2011; 51(1):15-22. PubMed ID: 21273739
[TBL] [Abstract][Full Text] [Related]
6. Rapid ventricular pacing for clip reconstruction of complex unruptured intracranial aneurysms: results of an interdisciplinary prospective trial.
Konczalla J; Platz J; Fichtlscherer S; Mutlak H; Strouhal U; Seifert V
J Neurosurg; 2018 Jun; 128(6):1741-1752. PubMed ID: 28820303
[TBL] [Abstract][Full Text] [Related]
7. Discrepancy between voluntary movement and motor-evoked potentials in evaluation of motor function during clipping of anterior circulation aneurysms.
Suzuki K; Mikami T; Sugino T; Wanibuchi M; Miyamoto S; Hashimoto N; Mikuni N
World Neurosurg; 2014 Dec; 82(6):e739-45. PubMed ID: 24036339
[TBL] [Abstract][Full Text] [Related]
8. Ischemia changes and tolerance ratio of evoked potential monitoring in intracranial aneurysm surgery.
Kang D; Yao P; Wu Z; Yu L
Clin Neurol Neurosurg; 2013 May; 115(5):552-6. PubMed ID: 22795547
[TBL] [Abstract][Full Text] [Related]
9. Comparison of false-negative/positive results of intraoperative evoked potential monitoring between no and partial neuromuscular blockade in patients receiving propofol/remifentanil-based anesthesia during cerebral aneurysm clipping surgery: A retrospective analysis of 685 patients.
Kim SH; Jin SJ; Karm MH; Moon YJ; Jeong HW; Kim JW; Ha SI; Kim JU
Medicine (Baltimore); 2016 Aug; 95(34):e4725. PubMed ID: 27559984
[TBL] [Abstract][Full Text] [Related]
10. Microsurgical Clipping of Intracranial Aneurysms Assisted by Neurophysiological Monitoring, Microvascular Flow Probe, and ICG-VA: Outcomes and Intraoperative Data on a Multimodal Strategy.
Della Puppa A; Rossetto M; Volpin F; Rustemi O; Grego A; Gerardi A; Ortolan R; Causin F; Munari M; Scienza R
World Neurosurg; 2018 May; 113():e336-e344. PubMed ID: 29452324
[TBL] [Abstract][Full Text] [Related]
11. The efficacy of motor-evoked potentials on cerebral aneurysm surgery and new-onset postoperative motor deficits.
Irie T; Yoshitani K; Ohnishi Y; Shinzawa M; Miura N; Kusaka Y; Miyazaki S; Miyamoto S
J Neurosurg Anesthesiol; 2010 Jul; 22(3):247-51. PubMed ID: 20548170
[TBL] [Abstract][Full Text] [Related]
12. Intraoperative Combined Use of Somatosensory Evoked Potential, Microvascular Doppler Sonography, and Indocyanine Green Angiography in Clipping of Intracranial Aneurysm.
Li Z; Zhang G; Huang G; Wang Z; Tan H; Liu J; Li A
Med Sci Monit; 2016 Feb; 22():373-9. PubMed ID: 26845425
[TBL] [Abstract][Full Text] [Related]
13. Somatosensory-evoked potential monitoring during instrumented scoliosis corrective procedures: validity revisited.
Thirumala PD; Bodily L; Tint D; Ward WT; Deeney VF; Crammond DJ; Habeych ME; Balzer JR
Spine J; 2014 Aug; 14(8):1572-80. PubMed ID: 24361128
[TBL] [Abstract][Full Text] [Related]
14. Diagnostic accuracy of somatosensory evoked potentials during intracranial aneurysm clipping for perioperative stroke.
Kashkoush AI; Nguyen C; Balzer J; Habeych M; Crammond DJ; Thirumala PD
J Clin Monit Comput; 2020 Aug; 34(4):811-819. PubMed ID: 31399827
[TBL] [Abstract][Full Text] [Related]
15. The incidence of and risk factors for ischemic complications after microsurgical clipping of unruptured middle cerebral artery aneurysms and the efficacy of intraoperative monitoring of somatosensory evoked potentials: A retrospective study.
Byoun HS; Bang JS; Oh CW; Kwon OK; Hwang G; Han JH; Kim T; Lee SU; Jo SR; Kim DG; Park KS
Clin Neurol Neurosurg; 2016 Dec; 151():128-135. PubMed ID: 27838495
[TBL] [Abstract][Full Text] [Related]
16. Impact of changes in intraoperative somatosensory evoked potentials on stroke rates after clipping of intracranial aneurysms.
Wicks RT; Pradilla G; Raza SM; Hadelsberg U; Coon AL; Huang J; Tamargo RJ
Neurosurgery; 2012 May; 70(5):1114-24; discussion 1124. PubMed ID: 22067420
[TBL] [Abstract][Full Text] [Related]
17. Transcranial motor evoked potential monitoring during the surgical clipping of unruptured intracranial aneurysms.
Yeon JY; Seo DW; Hong SC; Kim JS
J Neurol Sci; 2010 Jun; 293(1-2):29-34. PubMed ID: 20409559
[TBL] [Abstract][Full Text] [Related]
18. Motor evoked potential monitoring during surgery of middle cerebral artery aneurysms: a cohort study.
Yue Q; Zhu W; Gu Y; Xu B; Lang L; Song J; Cai J; Xu G; Chen L; Mao Y
World Neurosurg; 2014 Dec; 82(6):1091-9. PubMed ID: 25220340
[TBL] [Abstract][Full Text] [Related]
19. A new criterion for the alarm point using a combination of waveform amplitude and onset latency in Br(E)-MsEP monitoring in spine surgery.
Kobayashi K; Ando K; Shinjo R; Ito K; Tsushima M; Morozumi M; Tanaka S; Machino M; Ota K; Ishiguro N; Imagama S
J Neurosurg Spine; 2018 Oct; 29(4):435-441. PubMed ID: 30052151
[TBL] [Abstract][Full Text] [Related]
20. Differential rates of false-positive findings in transcranial electric motor evoked potential monitoring when using inhalational anesthesia versus total intravenous anesthesia during spine surgeries.
Tamkus AA; Rice KS; Kim HL
Spine J; 2014 Aug; 14(8):1440-6. PubMed ID: 24209393
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]