BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 29576494)

  • 21. CT guided percutaneous renal biopsy versus ultrasound guided for obtaining adequate tissue.
    Mukhtar KN; Mahmood SN; Umair SF
    J Pak Med Assoc; 2012 Sep; 62(9):880-2. PubMed ID: 23139967
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Transjugular biopsy of the liver in pediatric and adult patients using an 18-gauge automated core biopsy needle: a retrospective review of 410 consecutive procedures.
    Smith TP; Presson TL; Heneghan MA; Ryan JM
    AJR Am J Roentgenol; 2003 Jan; 180(1):167-72. PubMed ID: 12490497
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Transjugular liver biopsy using ultrasonographic guidance for jugular vein puncture and an automated device for hepatic tissue sampling: a retrospective analysis of 200 consecutive cases.
    Soyer P; Fargeaudou Y; Boudiaf M; Rymer R
    Abdom Imaging; 2008; 33(6):627-32. PubMed ID: 18180981
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Combined sonographic and fluoroscopic guidance during transjugular hepatic biopsies performed in children: a retrospective study of 74 biopsies.
    Habdank K; Restrepo R; Ng V; Connolly BL; Temple MJ; Amaral J; Chait PG
    AJR Am J Roentgenol; 2003 May; 180(5):1393-8. PubMed ID: 12704057
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Transjugular liver biopsy in 52 patients with an automated Trucut-type needle.
    De Hoyos A; Loredo ML; Martínez-Ríos MA; Gil MR; Kuri J; Cárdenas M
    Dig Dis Sci; 1999 Jan; 44(1):177-80. PubMed ID: 9952240
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The utility of ultrasound guidance in transjugular liver biopsy: our experience.
    Sebastian B; Singhal S; Botcha S; Madhurkar R; Thiruchunapalli D; Uthappa MC
    Abdom Radiol (NY); 2019 Feb; 44(2):749-755. PubMed ID: 30132093
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Safety and Efficacy of Transjugular Liver Biopsy in Patients with Left Lobe-Only Liver Transplants.
    Lee KA; Taylor A; Bartolome B; Fidelman N; Kolli KP; Kohi M; Kohlbrenner R; Laberge J; Lehrman E; Kerlan R
    J Vasc Interv Radiol; 2019 Jul; 30(7):1043-1047. PubMed ID: 30772167
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Pediatric percutaneous renal biopsies: comparison of complications between real-time ultrasound guidance and pre-procedure ultrasound-aided skin-marking techniques.
    Hayatghaibi SE; Ashton DJ; Orth RC
    Pediatr Radiol; 2019 May; 49(5):626-631. PubMed ID: 30552437
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Nonfocal renal biopsies: adequacy and factors affecting a successful outcome.
    Goldstein MA; Atri M; O'Malley M; Jacks L; John R; Herzenberg A; Reich H; Ghai S
    J Comput Assist Tomogr; 2013; 37(2):176-82. PubMed ID: 23493206
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Percutaneous CT fluoroscopy-guided core biopsy of pancreatic lesions: technical and clinical outcome of 104 procedures during a 10-year period.
    Strobl FF; Schwarz JB; Haeussler SM; Paprottka PM; Rist C; Thierfelder KM; Boeck S; Heinemann V; Reiser MF; Trumm CG
    Acta Radiol; 2017 Aug; 58(8):906-913. PubMed ID: 27856804
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Percutaneous liver biopsy in Fontan patients.
    Srinivasan A; Guzman AK; Rand EB; Rychik J; Goldberg DJ; Russo PA; Cahill AM
    Pediatr Radiol; 2019 Mar; 49(3):342-350. PubMed ID: 30506328
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Safety of Percutaneous Biopsy for Hepatic Angiosarcoma: Results of a Multicenter Korean Survey.
    Kang TW; Lee MW; Choi D; An C; Kim MJ; Joo I; Lee SJ; Lim S; Park JG; Seo JW; Jung SH
    J Vasc Interv Radiol; 2016 Jun; 27(6):846-51. PubMed ID: 27080009
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Transjugular liver biopsy: retrospective study performed on 71 patients].
    Quevedo E; Tan J; Araujo G; Morales H; Távara F
    Rev Gastroenterol Peru; 2003; 23(4):254-8. PubMed ID: 14716419
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Measuring hemoglobin prior to early discharge without routine surveillance ultrasound after percutaneous native renal biopsy in children.
    Muthusami P; Sunder S; Gallibois C; Kitamura E; Parra D; Amaral J; John P; Noone D; Connolly B
    Pediatr Nephrol; 2017 Oct; 32(10):1927-1934. PubMed ID: 28477259
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Transjugular liver biopsy with an automated device.
    Kardache M; Soyer P; Boudiaf M; Cochand-Priollet B; Pelage JP; Rymer R
    Radiology; 1997 Aug; 204(2):369-72. PubMed ID: 9240522
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Percutaneous renal biopsy in children: a 27-year experience.
    Feneberg R; Schaefer F; Zieger B; Waldherr R; Mehls O; Schärer K
    Nephron; 1998 Aug; 79(4):438-46. PubMed ID: 9689160
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Safety and efficacy of transjugular renal biopsy performed by interventional nephrologists.
    Sarabu N; Maddukuri G; Munikrishnappa D; Martin KJ; Qazi RA; Alvarez A; Schmitz PG
    Semin Dial; 2011; 24(3):343-8. PubMed ID: 21198847
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Transjugular liver biopsy.
    McAfee JH; Keeffe EB; Lee RG; Rösch J
    Hepatology; 1992 Apr; 15(4):726-32. PubMed ID: 1551649
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Associations of patient characteristics, disease stage, and biopsy technique with the diagnostic quality of core needle renal biopsy specimens from dogs with suspected kidney disease.
    Crivellenti LZ; Cianciolo R; Wittum T; Lees GE; Adin CA
    J Am Vet Med Assoc; 2018 Jan; 252(1):67-74. PubMed ID: 29244598
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Is Ultrasound Fusion a Reasonable Replacement for Computed Tomography in Guiding Abdominal Interventions?
    Ahmed Y; Novak RD; Nakamoto D; Azar N
    J Ultrasound Med; 2016 Jun; 35(6):1131-41. PubMed ID: 27091917
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.