These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 29577233)

  • 1. An assessment of the tolerability of the Cook staged extubation wire in patients with known or suspected difficult airways extubated in intensive care.
    McManus S; Jones L; Anstey C; Senthuran S
    Anaesthesia; 2018 May; 73(5):587-593. PubMed ID: 29577233
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Assessment of the reliability of intubation and ease of use of the Cook Staged Extubation Set-an observational study.
    Furyk C; Walsh ML; Kaliaperumal I; Bentley S; Hattingh C
    Anaesth Intensive Care; 2017 Nov; 45(6):695-699. PubMed ID: 29137579
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A prospective study of the safety of tracheal extubation using a pediatric airway exchange catheter for patients with a known difficult airway.
    Loudermilk EP; Hartmannsgruber M; Stoltzfus DP; Langevin PB
    Chest; 1997 Jun; 111(6):1660-5. PubMed ID: 9187190
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Tracheal extubation in children with difficult airways: a descriptive cohort analysis.
    Jagannathan N; Shivazad A; Kolan M
    Paediatr Anaesth; 2016 Apr; 26(4):372-7. PubMed ID: 26715011
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Extubation of the difficult airway.
    Faris K; Zayaruzny M; Spanakis S
    J Intensive Care Med; 2011; 26(4):261-6. PubMed ID: 21887863
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Safety and efficacy of Staged Extubation Set in patients with difficult airway: a prospective multicenter study.
    Corso RM; Sorbello M; Mecugni D; Seligardi M; Piraccini E; Agnoletti V; Gamberini E; Maitan S; Petitti T; Cataldo R
    Minerva Anestesiol; 2020 Aug; 86(8):827-834. PubMed ID: 32154681
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Tracheal extubation of the adult intensive care patient with a predicted difficult airway - a narrative review.
    Sturgess DJ; Greenland KB; Senthuran S; Ajvadi FA; van Zundert A; Irwin MG
    Anaesthesia; 2017 Feb; 72(2):248-261. PubMed ID: 27804108
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Airway challenges in critical care.
    Nolan JP; Kelly FE
    Anaesthesia; 2011 Dec; 66 Suppl 2():81-92. PubMed ID: 22074082
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Tolerability of the Cook staged extubation wire.
    Cooper RM; McCarthy S; Urdaneta F
    Anaesthesia; 2018 Sep; 73(9):1169-1170. PubMed ID: 30132817
    [No Abstract]   [Full Text] [Related]  

  • 10. Tolerability of the Cook staged extubation wire. A reply.
    McManus S; Anstey C; Jones L; Senthuran S
    Anaesthesia; 2018 Sep; 73(9):1170. PubMed ID: 30132813
    [No Abstract]   [Full Text] [Related]  

  • 11. Efficacy and safety of Cook staged Extubation Set in patients with difficult airway: a systematic review and meta-analysis.
    Lu C; Li J; Zhao S; Zhang Y
    BMC Anesthesiol; 2023 Jul; 23(1):232. PubMed ID: 37420175
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Safe extubation of a parturient using an airway exchange technique.
    Spong AD; Vaughan DJ
    Int J Obstet Anesth; 2014 Aug; 23(3):282-5. PubMed ID: 24913637
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The role of tracheal tube introducers and stylets in current airway management.
    Grape S; Schoettker P
    J Clin Monit Comput; 2017 Jun; 31(3):531-537. PubMed ID: 27084676
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dislocation rates of postoperative airway exchange catheters - a prospective case series of 200 patients.
    Roten FM; Steffen R; Kleine-Brueggeney M; Greif R; Wipfli M; Arnold A; Fischer H; Theiler L
    BMC Anesthesiol; 2019 Apr; 19(1):52. PubMed ID: 30971211
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Review article: Extubation of the difficult airway and extubation failure.
    Cavallone LF; Vannucci A
    Anesth Analg; 2013 Feb; 116(2):368-83. PubMed ID: 23302983
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Utility of airway exchange catheters in pediatric patients with a known difficult airway.
    Wise-Faberowski L; Nargozian C
    Pediatr Crit Care Med; 2005 Jul; 6(4):454-6. PubMed ID: 15982434
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Difficult tracheal tube passage and subglottic airway injury during intubation with the GlideScope
    Su K; Gao X; Xue FS; Ding GN; Zhang Y; Tian M
    Anaesthesia; 2017 Apr; 72(4):504-511. PubMed ID: 27995626
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Airway Management Strategies for Brain-injured Patients Meeting Standard Criteria to Consider Extubation. A Prospective Cohort Study.
    McCredie VA; Ferguson ND; Pinto RL; Adhikari NK; Fowler RA; Chapman MG; Burrell A; Baker AJ; Cook DJ; Meade MO; Scales DC;
    Ann Am Thorac Soc; 2017 Jan; 14(1):85-93. PubMed ID: 27870576
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intubation and extubation of the ICU patient.
    Quintard H; l'Her E; Pottecher J; Adnet F; Constantin JM; De Jong A; Diemunsch P; Fesseau R; Freynet A; Girault C; Guitton C; Hamonic Y; Maury E; Mekontso-Dessap A; Michel F; Nolent P; Perbet S; Prat G; Roquilly A; Tazarourte K; Terzi N; Thille AW; Alves M; Gayat E; Donetti L
    Anaesth Crit Care Pain Med; 2017 Oct; 36(5):327-341. PubMed ID: 28919068
    [No Abstract]   [Full Text] [Related]  

  • 20. The effects of lidocaine spray and intracuff alkalinized lidocaine on the occurrence of cough at extubation: a double-blind randomized controlled trial.
    D'Aragon F; Beaudet N; Gagnon V; Martin R; Sansoucy Y
    Can J Anaesth; 2013 Apr; 60(4):370-6. PubMed ID: 23370978
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.